Regency B36X Installation Checklist, Locating Your Gas Fireplace, This includes, Diagram

Models: B36X

1 64
Download 64 pages 45.68 Kb
Page 8
Image 8
INSTALLATION

INSTALLATION

INSTALLATION

CHECKLIST

1)Locate appliance

a)Room location (Refer to "Locating Your Gas fireplace" section)

b)Clearances to Combustibles (Refer to "Clearances" section)

c)MantelClearances(Referto"Combustible Mantel Clearances" section)

d)Framing&FinishingRequirements(Refer to "Framing & Finishing" section)

e)Venting Requirements (Refer to "Venting" section)

2)Assemble Top Standoffs and Top Facing Support and Side Nailing Strips (Refer to "Unit Assembly Prior to Installation" Section). NOTE: Must be done before installing unit into place.

3)Install vent (Refer to "Venting" sections).

4)Make gas and electrical connections. Test the pilot. Must be as per diagram (Refer to "Pilot Adjustment " section).

Convert to propane if desired (Refer to "Gas Line Installation" and "Conversion Kit from NG to LPG" sections).

5)Install standard and optional features. Refer to the following sections:

a.LP Conversion Kit (Optional)

b.Brick Panels (Optional)

c.Log Set Installation

d.Standard Flush Door

e.Full Screen Door (Optional)

f.Flush Panel/Louver (Optional)

g.Remote control,Wall Switch or Thermostat (Optional)

h.Fan Installation (Optional)

6)Final check.

This includes:

1)Clocking the appliance to ensure the correct firing rate (rate noted on label) after burning appliance for 15 minutes.

2)If required, adjusting the primary air to ensure that the flame does not carbon. First allow the unit to burn for 15-20 min. to stabilize.

CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibility of the manufacturer.

LOCATING YOUR

GAS FIREPLACE

1)When selecting a location for your fireplace, ensure that the clearances are met.

2)The appliance must be installed on a flat, solid, continuous surface For example a wood, metal or concrete floor or in a raised (on the wall) application. The appliance must be installed on a metal or wood panel extending the full width and depth of the appliance.

3)The B36X Bellavista™ Gas Fireplace can be installed in a recessed position or framed out into the room as in A, B, C and D. See Diagram 1.

Diagram 1

A)Flat on Wall

B)Flat on Wall Corner

C)Recessed into Wall/Alcove

D)Corner

4)This appliance is Listed for bedroom installations using the standard Remote (millivolt thermostat system). Some areas may have further requirements, check local codes before installation.

5)The B36X Gas Fireplace are approved for alcove installations, see "Clearances" section for details.

6)We recommend that you plan your installation on paper using exact measurements for clearances and floor protection before actually installing this appliance. Have an authorized inspector, dealer, or installer review your plans before installation.

Note: For vent terminations refer to "Exterior Vent Termination Locations" section.

HEATWAVE

DUCT SYSTEM

(OPTIONAL)

#946-556

The HeatWave Air Duct Kit increases the effectiveness of your fireplace by dispersing warm air from the fireplace to remote locations in the same room or other rooms in your home.

Up to two kits may be installed on the fireplace. Please Note: Only 1 HeatWave kit may be operated at one time. This includes the internal blower option as well.

8

Regency Bellavista™ B36X Gas Fireplace

Page 8
Image 8
Regency B36X Installation Checklist, Locating Your Gas Fireplace, HEATWAVE DUCT SYSTEM OPTIONAL #946-556, Diagram