Installation Instructions

Method 3: Housing unit with internal height 710mm or more

Note: You will not need the 4 runners and 2 trims that are packed with the oven for this installation.

Remove any fixings that may prevent entry of the oven into housing, or obstruct the gas inlet pipe. The cabinetry should be kept structurally sound by fixing to adjacent cabinets, floor or worktop.

 

 

560-570mm

547mm

 

min 550mm

 

 

9mm

 

min

703mm

 

 

710

 

 

706

697

mm

mm

 

mm

12mm gap in

 

595mm

plinth for air intake

 

 

550mm

 

1.When installed in a typical 600mm deep built in housing unit, the false back should be removed from the housing unit to provide the necessary depth for installation.

2.When the false back is removed, it is normally the case that the support shelf for the appliance leaves a gap between the back edge and the wall of approximately 80mm.

3.If no gap occurs between the back edge of the shelf and the wall behind the unit, you must create a gap of at least 30mm by shortening the shelf.

Worktop

space behind

appliance to

be kept clear

12mm air

support

gap in top

shelf

of plinth

 

Rear wall

32

Image 34
Contents Belling BI 70 G If you smell gas Important NoticeContents Introduction Your 1st Year GuaranteeEvent of a power cut Gas & Electrical connectionCooling fan For your safetyVentilation Disposal of packaging Glass door panelsCondensation To replace an oven light bulbBe Safe Not Sorry Never use the appliance for heating a roomPreheating Using the GrillGrill operation Aluminium foilUsing the grill Oven furniture Baking tray and roasting tins Using the OvensOven shelves Ignition top oven Using the top ovenZones of heat top oven Top oven baking guide CakesZones of heat main oven Baking guide hintsMain oven baking guide Roasting guide LambRoast Turkey Traditional fruit cakesCooking frozen & chilled foods Slow cookingSemi-Automatic cooking in the mainoven Do notProgrammer / Clock Programmer buttons To select an alarm toneSetting the minute minder To set the time of daySemi-automatic cooking Semi-automatic cooking Duration method End Time methodChrome plated parts CleaningAlways let the appliance cool before cleaning Enamel surfacesGlass parts Painted, plastic and metal finish parts if fittedStainless Steel surfaces stainless steel finish models only Installation Instructions UK the regulations and standards are as followsPrepare for installation Fixing Kit Shown with fixing kit Shown without fixing kit Before you start To fix the runners if requiredMin 550mm 560-570mm 710mm 687 mm Runners Min 550mm 560-570mm 12mm gap Connect to gas supply Make sure all connections are gas soundUse a 13 amp fuse Connect to the electricity supplyTypical example of a double pole fuse spur outlet Tosecure appliancetohousingunit Secure appliance into housing unitInstalling a hob above the appliance Commissioning Pressure test point Pressure settingBefore leaving the installation Burner aerationTechnical Data Belling Customer Care 0844 815