Glen Dimplex Home Appliances Ltd BI 70 G manual Commissioning Pressure test point, Burner aeration

Page 38

Installation Instructions

Step 6: Commissioning

Pressure test point

Use the oven burner. From inside the oven remove the burner cowl. Remove the small screw at the LHS of the burner cradle. Slide the burner to the left to access the injector. Connect manometer to the injector and turn the grill burner to full on to check pressure.

Replace in reverse order.

Burner aeration

All burners have fixed aeration and no adjustment is possible.

Pressure setting

G20 Natural Gas @ 20 mbar

Electrical systems check

In the event of an electrical fault the preliminary electrical system check (earth continuity, short circuit, polarity and resistance to earth) must be carried out.

Ignition

The automatic ignition continues to spark for a short time after the burner has lit until the flame is established.

Oven (Top and Main)

Push in and turn the main oven control knob anti clockwise to the ‘FULL ON’ position (gas mark 9). The ignition system will spark automatically. Push in the control knob to ignite the gas. The sparking will stop. If after 15 seconds, the burner has not lit, turn off the oven and leave the compartment door open. Wait at least one minute before a further attempt to ignite the burner.

Do not hold the control knob in for more than 15 seconds.

Turn the control knob clockwise to the required setting.

To turn off, return the control knob to the “off” position.

Grill

1.The door must be open for grilling.

2.Push in and turn the control knob clockwise to the grill symbol.

When you first turn on the oven or grill you may notice a smell and some smoke which comes from the protective coating of oil burning off from some of the parts.

Before leaving the installation

Show the customer how to use the oven and grill, and give them this handbook. Thank you.

36

Image 38
Contents Belling BI 70 G If you smell gas Important NoticeContents Introduction Your 1st Year GuaranteeEvent of a power cut Gas & Electrical connectionVentilation For your safetyCooling fan Disposal of packaging Glass door panelsCondensation To replace an oven light bulbBe Safe Not Sorry Never use the appliance for heating a roomPreheating Using the GrillGrill operation Aluminium foilUsing the grill Oven shelves Using the OvensOven furniture Baking tray and roasting tins Zones of heat top oven Using the top ovenIgnition top oven Top oven baking guide CakesZones of heat main oven Baking guide hintsMain oven baking guide Roasting guide LambRoast Turkey Traditional fruit cakesCooking frozen & chilled foods Slow cookingSemi-Automatic cooking in the mainoven Do notProgrammer / Clock Programmer buttons To select an alarm toneSetting the minute minder To set the time of daySemi-automatic cooking Semi-automatic cooking Duration method End Time methodChrome plated parts CleaningAlways let the appliance cool before cleaning Enamel surfacesGlass parts Painted, plastic and metal finish parts if fittedStainless Steel surfaces stainless steel finish models only Installation Instructions UK the regulations and standards are as followsPrepare for installation Fixing Kit Shown with fixing kit Shown without fixing kit Before you start To fix the runners if requiredMin 550mm 560-570mm 710mm 687 mm Runners Min 550mm 560-570mm 12mm gap Connect to gas supply Make sure all connections are gas soundTypical example of a double pole fuse spur outlet Connect to the electricity supplyUse a 13 amp fuse Installing a hob above the appliance Secure appliance into housing unitTosecure appliancetohousingunit Commissioning Pressure test point Pressure settingBefore leaving the installation Burner aerationTechnical Data Belling Customer Care 0844 815