Zenoah EDG2300 manual Inspection Every 100 Hours

Page 15

Maintenance

Check and clean the spark plug. Adjust the electrode gap to .024~.028in (0.6~0.7mm) if necessary.

.024 ~ .028 in (0.6~0.7mm)

Replacement plug: NGK BPMR7A

INSPECTION EVERY 100 HOURS

The muffler is equipped with a spark arrester to prevent red hot carbon from flying out of the exhaust outlet. In the State of California it is required by law (Section 4442 of the California Public Resources Code) to equip a spark arrester when a gas powered tool is used in any forest covered, brush covered, or grass covered unimproved land.

Speak

Arrester

Check and tighten each fastener.

Dismount the engine and check the clutch system to see if oil is observed between the clutch lining and its drum. If any, wipe it off with gasoline.

15

Image 15
Contents EDG2300 Safety First Contents  4  Safety PrecautionsWork Gear and Clothing Things to Check Before Using Your Portable GAS Drill Avoid Noise ProblemThings to Check Before Starting UP the Engine  7  Important Engine Information Emission Control LabelParts Location & Specifications SetupModel EDG2300 HOW to MIX Fuel FuelRecommended Mixing Ratio Gasoline 50OIL For Your Engine LIFE, Avoid Fueling the UnitStarting Engine OperationAdjustment of Idling Speed Stopping EngineBoring Operation Inspection Every 25 Hours MaintenanceMaintenance Chart Daily InspectionInspection Every 100 Hours Storage DisposalBefore LONG-TERM Storage Parts List Drive Unit and Tools S/N 901112 and up Parts List EDG2300EDG2300  20   21  Limited Warranty Garantie limitée Zenoah AMERICA, INC