•If local codes permit, use a flexible stainless steel tubing gas connector,
rear of side
burner1/2" side burner gas pipe
flexible gas connector
•
3.Open shutoff valve in the gas supply line. The valve is open when the handle is parallel to the gas pipe.
valve open
valve closed
4.Test all connections by brushing on an approved
Correct any leak found.
5.Carefully lift off cover and grate and set aside. Remove packing from around burners. Reinstall grate.
cover
grate
6.Carefully move Side Burner completely into enclosure.
7.Go to "Checking and adjusting the burners".
Checking and adjusting the burners
The burners are tested and
Checking and adjusting the burner flames requires removing the grate.
Low flame adjustment:
If flame goes out on the LO setting, the low flame setting must be adjusted.
Light the burner and turn control knob to its lowest setting and remove knob. Hold the valve stem with pliers and insert a thin flat blade screwdriver into the shaft. Watch the flame and slowly turn screwdriver counterclockwise. Adjust flame to the minimum stable flame. Replace control knob.
Reassemble grate.
valve stem
Copies of the standards listed may be obtained from:
*CSA International
8501 East Pleasant Valley Rd. Cleveland, Ohio
**for local codes, contact your local building inspector
®Teflon is a registered trademark of E.I. Du Pont de Nemours and Company.
Use and Care of your Side Burner
Using your Side Burner
WARNING
Burn Hazard
Do not let the burner flame extend beyond the edge of the pan.
Doing so can result in burns.
WARNING
Food Poisoning Hazard
Do not let food sit for more than one hour before or after cooking
Doing so can result in food poisoning or sickness.
1.Remove side burner cover. Do not light burners with the cover on.
2.Make sure control knobs are turned to OFF.
3.Turn the gas supply on:
Natural gas or L.P. gas from a local supply.
•Using gas supply source other than L.P. gas cylinder:
Turn the shutoff valve to open position from the front of gas supply line.
L.P. gas cylinder, if converted (see "Gas Supply Requirements").
•Using an L.P./ propane gas cylinder:
Slowly open the cylinder valve; do not “snap” open.
NOTE: When using an L.P. gas cylinder, the flow limiting device may activate and your side burner may not light. If your side burner does light, the flames will be low and will not heat properly. Turn cylinder valve and all control knobs off and wait 30 seconds. After shutting off the cylinder, very slowly open cylinder valve and wait 5 seconds before lighting.
6