KitchenAid KBZU122VSS installation instructions Gas Connection Requirements

Page 11

Gas Conversion:

No attempt shall be made to convert the side burner from the gas specified on the model/serial rating plate for use with a different gas type without consulting the serving gas supplier. The conversion kits supplied with the side burner must be used. See “Gas Conversions” section for instructions.

Gas Pressure Regulator

The gas pressure regulator supplied with this side burner must be used. The inlet (supply) pressure to the regulator should be as follows for proper operation:

LP Gas:

Set pressure: 11" (27.9 cm) WCP

Inlet (supply) pressure: 11" to 14" (27.9 cm to 35.5 cm) WCP

Natural Gas:

Set pressure: 4" (10.2 cm) WCP

Inlet (supply) pressure: 7" to 14" (17.8 cm to 35.5 cm) WCP maximum.

Contact local gas supplier if you are not sure about the inlet (supply) pressure.

Burner Requirements for High Altitude

Input ratings shown on the model/serial rating plate are for elevations up to 2,000 ft (609.6 m).

For elevations above 2,000 ft (609.6 m), ratings are reduced at a rate of 4% for each 1,000 ft (304.8 m) above sea level. Orifice conversion is required. See “Assistance or Service” section to order.

Gas Supply Line Pressure Testing

Testing above ½ psi (3.5 kPa) or 14" (35.5 cm) WCP (gauge):

The side burner and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures greater than ½ psi (3.5 kPa).

Testing below ½ psi (3.5 kPa) or 14" (35.5 cm) WCP (gauge) or lower:

The side burner must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psi (3.5 kPa).

Gas Connection Requirements

For Models Equipped for LP Gas

20 lb LP Gas Fuel Tank

This side burner is equipped for use with a 20 lb LP gas fuel tank (fuel tank not supplied). A gas pressure regulator/hose assembly is supplied.

It is also design-certified by CSA International for local LP gas supply or for Natural gas with appropriate conversion.

A

A. Gas pressure regulator/hose assembly

The 20 lb LP gas fuel tank must be mounted and secured.

Door Style Tank Tray

1.Open cabinet doors.

2.Pull out the tank tray.

Tank tray

3.Place the 20 lb LP gas fuel tank bottom collar into the mounting hole in the tank tray.

4.Tighten the locking screw against the bottom collar of the 20 lb LP gas fuel tank to secure.

A

BC

A.Locking screw

B.Mounting hole

C.Bottom collar

5.Slide tank tray back into the cabinet.

6.Close cabinet doors.

Local LP Gas Supply Conversion

Conversion must be made by a qualified gas technician. The qualified gas technician shall provide the gas supply to the selected side burner location in accordance with the National Fuel Gas Code ANSI Z223.1/NFPA 54 - latest edition, and local codes. For conversion to local LP, the convertible regulator in the conversion kit supplied with the side burner must be used.

IMPORTANT: The gas installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 - latest edition. The qualified LP gas technician shall provide the LP gas supply to the selected side burner location in accordance with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 and local codes.

Follow instructions for converting to local LP gas in the “Gas Conversions” section.

A

B

C

A. New CSA International approved “outdoor” flexible gas supply line

B. Rear of side burner C. To local LP gas supply

11

Image 11
Contents Outdoor BUILT-IN Dual Side Burners Table DES Matières Your safety and the safety of others are very important Outdoor BUILT-IN Side Burner SafetyImportant Safety Instructions Parts Supplied Installation RequirementsTools and Parts Lb LP Gas Models KBZU122VSS00 Tools NeededLocation Requirements Product DimensionsMaker Ice Cabinet DimensionsBetween a Trash Drawer, Utility Drawer, or Warming Drawer Built-in Outdoor Grill Enclosure Ventilation for LP Gas Recommended Ground Method Electrical RequirementsGas Supply Requirements Gas Connection Requirements Natural Gas LP Gas Conversion Using a Local LP Gas SupplyNatural Gas Conversion LP Gas Conversion Using a 20 lb LP Gas Fuel Tank Installation InstructionsBuilt-inOutdoor Side Burner Installation Install Tank Tray for20lb LP Gas FuelTankMake Gas Connection To Install the 20 lb LP Gas Fuel TankPlug in Side Burner Gas Connection to Natural Gas or Local LP GasAssemble Cooking Area Conversionto aLocal LP Gas Supply Installation of the regulatorGAS Conversions Tools and Parts forGas ConversionRecord Conversion Conversion from LP Gasto Natural GasMake Side Burner Connections Connect Local LP Gas Supply Change the Side burner orifices Check and Adjust theBurnersHook up to Natural gas and Leak Test Lighting Your SideBurner Using Your Outdoor Side BurnerManually lighting the side burner General CleaningCleaning Method Outdoor Side Burner CareNothing will operate TroubleshootingAssistance or Service If you need replacement partsCanada Kitchenaid Outdoor Product WarrantyAccessories TheU.S.AThis limited warranty does not cover Items Excluded from WarrantyVotre sécurité et celle des autres est très importante Sécurité DU Brûleur Latéral Encastré DextérieurConservez CES Instructions Pièces nécessaires Exigences DinstallationOutillage et pièces Pièces fourniesAllumage ExigencesdemplacementDimensionsdu produit Dimensions du placardPlan Dimension C Dimension D Dimension E Taille de la porte Dimension F Dimension L Dimensions de louverture à découper Portes daccès encastréesSpécifications delalimentation en gaz Méthode recommandée de mise à la terreSpécifications électriques Test de pressurisation de la canalisation de gaz Exigences concernantle raccordement au gazDétendeur Puissance thermique des brûleurs en altitudeConversion pour lalimentation au gaz naturel Gaz naturel Instructions ’INSTALLATIONInstallationdubrûleurlatéral dextérieur Encastré Exigences concernantleraccordement au gazInstallation du chariot de bouteille de gaz propane de 20lb Raccordement à une bouteille de gaz propane de 20 lb Installation de la bouteille de propane de 20 lbRaccordement de gaz Branchement du brûleur latéral Alimentation au gaz naturel ou au gaz propane localOutils nécessaires Installation de la zone de cuissonConversions DE GAZ OutillageetpiècesConversion au gaz propanelocal Installation du détendeurEnregistrer la conversion Conversion degaz propaneàGaznaturelEnregistrement de la conversion Remplacement des gicleurs du brûleur latéralContrôle et réglagedes brûleurs Raccordement au gaz naturel et recherche des fuitesOuvrir larrivée de gaz AllumagedubrûleurlatéralPréparation de l’alimentation en gaz Méthode de nettoyage Entretien DU Brûleur Latéral DextérieurNettoyage général Allumage manuel du brûleur latéralRien ne fonctionne DépannageAu Canada Assistance OU ServiceAccessoires La présente garantie limitée ne couvre pas Garantie DES Produits Pour Usage Extérieur KitchenaidAll rights reserved W10176789B
Related manuals
Manual 48 pages 54.09 Kb

KBZU122VSS specifications

The KitchenAid KBZU242VSS, KBZU122VSS, KBZU122TSS, and W10176789A are a series of impressive kitchen appliances designed to enhance your culinary experience. These products appeal to both amateur and professional chefs due to their innovative features, advanced technologies, and sleek design.

The KBZU242VSS is a built-in refrigerator that offers an impressive combination of style and functionality. It boasts a spacious capacity optimized for convenient organization. The design includes adjustable glass shelves and a customizable door bin system, allowing you to create a layout that suits your storage needs. One of its standout features is the ExtendFresh technology, which ensures that all your food items are stored at the ideal temperature to maintain freshness.

Next, the KBZU122VSS is known for its compact size, making it perfect for smaller kitchens or as an additional cooling solution wherever you need it. With a stylish stainless steel finish, it seamlessly integrates into any kitchen decor. Its Energy Star rating reflects its efficient power consumption, making it an eco-friendly choice. The interior layout includes removable shelving and a dedicated crisper drawer for fruits and vegetables, ensuring that your produce stays fresh longer.

The KBZU122TSS shares many features with its counterpart but may include additional customizable options or slightly varied designs, catering to diverse consumer preferences. This model emphasizes flexibility, allowing chefs to maximize their kitchen space without sacrificing functionality. The bright LED lighting inside provides excellent visibility, making it easy to find items even in densely packed storage.

Finally, the W10176789A is not just an accessory but a significant upgrade for your kitchen. This model is designed for seamless compatibility with various appliances, enhancing their overall performance. Whether it's improving temperature regulation or streamlining your cooking process, it has been engineered with precision in mind.

In summary, the KitchenAid KBZU series, featuring the KBZU242VSS, KBZU122VSS, KBZU122TSS, and the W10176789A, represents a range of high-quality kitchen appliances that prioritize efficiency, adaptability, and style. Their unique features and innovative technologies provide users with smart and practical solutions for all their cooking and cooling needs. Ideal for enhancing any kitchen, these appliances are a testament to KitchenAid's commitment to quality and design excellence.