ACCESSORIES

Purchase the accessories from your local dealer or Parts Central. If they cannot supply these accessories call PRO-COM’s Sales Department at 1-877-886-5989 for referral information. You can also write to the ad- dress listed on the back page of this manual.

HIGH ALTITUDE DERATE

In the U.S.A., Input BTU shall be derated 4%(1 orifice size) per 1000ft, for above 2000ft.. In Canada, input BTU shall be derated 10% (2 orifice size) at altitudes from 2000ft.to 4500ft..

 

SPECIFICATIONS

Model

L600HYLA/B

PN750HYLA/B

Btu (LP/NG)

60.000

75.000

Gas Type

LP

NG

Ignition

Piezo

Piezo

Inlet Gas Pressure* (In. of water)

 

Maximum

14”

10.5”

Minimum

11”

5.5”

Dimensions, Inches

(H x W x D)

 

Stove

17 3/4” x22 7/8”x18 1/8”

17 3/4” x22 7/8”x18 1/8”

Carton

15” x25 ”x20 1/4”

15” x25 ”x20 1/4”

Weight, Lbs

 

 

Stove

32/33

32/ 33

Shipping Weight

55/58

55/ 58

* For purpose of shipment adjustment.

Minimum clearances: Bottom:

(This appliance may not be place on any combustible materials)

Top:

8 FT. (2.4m)

Side /walls (around): 48 inch (1220mm)

TROUBLESHOOTING

OBSERVED PROBLEM

Burner does not light

When ignitor buttons pressed in, there is no spark at safety Pilot.

Burner fire does not last.

POSSIBLE CAUSE

1.Air in gas lines.

2.Inlet gas pressure is too low.

3.Gas supply turned off.

4.Air passageway on heater blocked.

5.Burner orifice clogged.

6.Control knob not in ING/ON position.

7.Control knob not fully pressed in while in ING/ON position.

1.Ignitor electrode positioned wrong.

2.Ignitor broken.

3.Broken ignitor cable.

4.Ignitor electrode not connected to ignitor cable.

1.Damaged thermocouple.

2.Thermocouple electrode corrosion.

3.Damaged control valve.

4.Control knob not pressed long enough.

5.Thermocouple connection loose at control valve.

6.Pilot flame not touching thermocouple.

REMEDY

1.Continue holding down control knob. Repeat igniting operation until air is removed.

2.Check gas pressure.

3.Fully open gas supply.

4.Check air passageway.

5.Clean burner.

6.Turn control knob to ING/ON position.

7.Press down control knob.

1.Reposition ignitor.

2.Replace pilot

3.Replace ignitor cable.

4.Connect electrode to ignitor cable.

1.Replace thermocouple.

2.Clean thermocouple electrode.

3.Replace control valve.

4.After pilot lights, keep control knob pressed in for 30 seconds.

5.Hand tighten connection or replace thermocouple.

6.Contact qualified service man.

10

Image 10
Contents OWNER’S Operation and Installation Manual Table of Contents Safety Information LocationLocation Continue Local CodesInstallation Installation continue Operating Heater Connecting to GAS SupplyFuel Requirements Maintenance and Storage Lighting InstructionsService Indications Product FeaturesReplacement Accessories TroubleshootingHigh Altitude Derate Parts List Illustrated Parts BreakdownPRO-COM TOLL- Free Number 1- 877- 886