Location Continue
Note :If pipe is to be placed in an underground trench, check with local codes for required depth and mate- rial construction.
4.Connect the 3/8” male flare brass fitting (furnished with campfire) to the 1/2” steel piping making sure to clean the pipe threads and use Teflon tape or pipe dope.(FLEX LINE NOT SUPPLIED)
5.Connect the 1/2” female X 3/8” male flare brass fitting to the 3/8” female brass flare fitting, as
sembled on the right side of the gas line, of the right side of the campfire.
NOTE: Brass to brassw connections do not require teflon tape or pipe dope.
(Note: show drawing of hard piping installation.
Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.
Young children should be carefully supervised when they are in the area of the appliance.
Never leave the appliance unattended during
operation.
Clothing or other flammable materials should not be placed on or near the appliance.
∙ Any guard or other protective device removed for servicing the appliance must be replaced prior to operating the appliance
∙ Installation and repair should be done by a quali- fied service person.. The appliance should be in- spected before use and at least annually by a quali- fied service person. More frequent cleaning may be required as necessary. It is imperative the con- trol compartment, burners and circulating air pas- sageways of the appliance be kept clean.
∙ Inspect the fuel supply connection before each use of the appliance.
Storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply. (natural gas line or LP gas)
LOCAL CODES
Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANSZ223.1, also known as NFPA54*.
Available from :
American National Standards Institute, INC.
1430 Broadway, New York, NY10018 National Fire Protection Association, INC. Battery march Park Quincy. MA 02269
Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of control system and any gas control which has been under water.
IMPORTANT: Installation of natural gas and LP should be done by a qualified installer, service agency or gas supplier.
The appliance and its manual shutoff valve must be disconnected from the gas supply piping sys- tem during any pressure testing of the system at test pressures in excess of 1/2 psig (3.5kPa).
This appliance must be isolated from the gas supply piping system by closing its manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5kPa).
4