CATALYTIC COMBUSTOR, REPLACEMENT

The catalytic thermometer on top of the stove should read in the active zone after the stove has been in operation for several hours. If the thermometer's indicator needle does not stay above the 1/3 mark in the active zone, even with a hot fire, over a 7-10 day period of regular use, the catalyst may need replacement. If the combustor must be examined or replaced, follow this procedure:

1.Allow the stove to burn out and cool down.

2.Open the door and remove the flame shield - the perforated plate that is just above the inside of the door open- ing. Lift it slightly and pull it forward and down.

3.The combustor may now be seen. The combustor is held together by a stainless steel band. Use a screwdriver and gently pry under the band at each end. The combustor will loosen enough that it can be pulled forward, lowered and out through the door.

4.The insulating material around the stainless band will probably disintegrate as the combustor is removed. If the combustor is placed back in the stove, the insulating material MUST be replaced. Obtain a piece 2" x 30” from your dealer. When installing the insulation, ensure the ends are butted closely together.

5.Do not burn the stove with the combustor removed, or without the insulation around the combustor.

6.To replace the combustor, first clean the combustor seat and the area around it. Also take this opportunity to clean the area around the by-pass -- use a vacuum cleaner.

7.Lift the new combustor into position, with the stainless flanges on each end and the bottom. The combustor should easily slide into position, as far to the back of the stove as possible. Don't be concerned if it appears a bit loose. The insulation around the outside of the stainless band will expand during the first fire and will hold the combustor in.

8.Replace the flame shield (the Perforated plate) by holding it inside the firebox with the triangular wings facing away from you. Lift it into position, between the door and the catalyst, and rest the bottom of the plate on the two pins that protrude below the catalyst. The flame shield should rest at an angle (about 45 degrees) with its bottom near the combustor, and its top near the stove front.

DOOR GLASS, CLEANING

The best way to keep the glass clean is to leave the stove on high burn for a period of time after each reloading. The moisture which is driven from a new load of wood contributes much of the creosote on the inside of the glass. Removing that moisture at the beginning of the burn cycle helps to keep the glass clean. Leaving the thermostat on a higher setting for 30 minutes to an hour before turning to low for an overnight burn will also help. Even then the glass may coat during a low burn. Heavier deposits may require hand cleaning. Manual glass cleaning should be done when the stove and glass are cool. DO NOT CLEAN THE GLASS WHILE IT IS HOT. Use a soft cloth and a NONABRASIVE household cleaner. After using any cleaner, thoroughly rinse the glass with water to remove any deposits left by the cleaner. Failure to remove all traces of glass cleaner will result in the glass cleaner residue bak- ing on. This residue may be very difficult to remove.

DOOR GLASS, REPLACEMENT

Your BLAZE KING is equipped with a door which uses a strong, heat-resistant ceramic glass intended to withstand extremely high temperatures and tested for continuous use above 1200 degrees Fahrenheit. However, this glass can be broken through improper use. If glass replacement becomes necessary, use only BLAZE KING GLASS. DO NOT SUBSTITUTE ANY OTHER MATERIAL FOR THIS PURPOSE.

WARNING

BROKEN DOOR GLASS IS SHARP. ALWAYS WEAR EYE PROTECTION AND PROTECTIVE GLOVES WHEN

HANDLING GLASS. DISCARD THE GLASS IN A CLOSED CONTAINER INACCESSIBLE TO CHILDREN.

Allow the fire to completely burn out and the stove to cool down.

1.Retain all metal parts for re-installation.

2.Open the door and remove the door gasket, then remove the nuts holding the retainers to the inside of the door.

3.Remove the damaged glass and the old glass gasket.

4.The replacement glass has the gasket installed on its outer perimeter. Place the glass in the door frame. Be sure the words "Blaze King" etched in the glass read correctly when the door is closed.

5.Replace the gasket and reinstall the retainers with the proper nuts.

PI-1010A

Page 27

DATE PRINTED: 2/8/05

Revision Date: 02/01/05

Image 27
Contents Princess Insert Princess Insert Approval LabelTo Our Valued Customers Blaze KingChimneys Masonry Fireplace Safety NoticeTable Of Contents Operation HOW YOU can GET Service WarrantyDefinitions Draft Combustion AIR IntakeCreosote Formation and Need for Removal DOOR, LoadingICE Formation and Prevention FlueFuel This Stove is for USE with Solid Wood Fuel only HearthSafety Clearances to Combustible Materials CleaningChildren ChimneysLoading Door Electrical PowerFuel Disposal of AshesSpecifications Facts On BTU’sBtu Ratings PI1010A Chimney Height Affects Draft Preparation And AssemblyPlanning for Your Stove Placement Inspect Your Chimney22 559 mm Flame SHIELD, Installation Tools Needed for InstallationStove Assembly Combustor ASSEMBLY, InstallationAssembly Instructions for Princess PI1010A Insert Assembly GeneralScrew Installation Into Factory Built Fireplaces Installation Chimney Chimney Installation GeneralChimneys FACTORY-BUILT Fireplace Fuel OperationFAN Operation Your First FireCouple of tips Maintenance Gasket Inspection Gasket ReplacementCatalytic COMBUSTOR, Testing Catalytic COMBUSTOR, CleaningCatalytic COMBUSTOR, Replacement Door GLASS, CleaningDoor GLASS, Replacement FAN Assembly Rheostat ReplacementPaint Chimney Fire TroubleshootingProblem Cause SolutionCause PROBLEM. Too much heatHazard and demands immediate attention Problem Door glass quickly becomes coated with creosoteOptional Kits Standard And Replacement PartsStandard & Replacements Parts Part NameDate Printed 2/8/05