Napoleon Fireplaces BGP42, BGD42 manual Logo Placement, Porcelain Reflective Panels

Page 21

LOGO PLACEMENT

Remove the backing of

 

 

 

FIGURE 40

the logo supplied and

 

 

 

place on the glass view-

 

 

 

 

ing door, as indicated.

½"

 

 

 

 

 

 

LOGO

½"

PORCELAIN REFLECTIVE PANELS

1.Remove the upper louvres, and open the glass door. Remove the logs.

2.Remove the two securing screws located on either fi rebox side.

3.Place the left panel against the left side of the fi rebox, ensuring that it butts up to the rear panel. Secure in place using 2 of the screws previously removed. Repeat for the right side.

4.Replace the logs, glass door and lou- vres.

FIGURE 41

GRATE INSTALLATION

FIGURE 42

The grate for this fi replace has been removed for shipping pur- poses.

The grate must be installed before the logs are installed.

Remove the packaging from the grate and install onto the two pins as illustrated.

21

LOG PLACEMENT

PHAZERTM logs and glowing embers, exclusive to Napoleon® Fire- places, provide a unique and realistic glowing effect that is different in every installation. Take the time to carefully position the glowing embers for a maximum glowing effect. Log colours may vary. During the initial use of the fireplace, the colours will become more uniform as colour pigments burn in during the heat activated curing process.

FIGURES 43a-e

1.Place the cutout in the bottom of log (W135-0297)behind the pilot assembly. Rest the log against the back wall of the fi rebox.

2.Move the two small logs (W135-0298 & W135-0299)into posi- tion, lining up the studs located on the burner with the holes on the bottom of the logs.

GLOWING EMBERS

3.Tear the glowing embers into pieces and place along the front row of ports covering all of the burner area in front of the small logs. Care should be taken to shred the embers into thin, small irregular pieces as only the exposed edges of the fi bre hairs will glow. The ember material will only glow when exposed to direct fl ame; however, care should be taken to not block the burner ports. Blocked burner ports can cause an incorrect fl ame pattern, carbon deposits and delayed ignition. PHAZERtm logs glow when exposed to direct fl ame.

4.Place the bottom of the left crossover log (W135-0300)onto the stud on the left side of the log support. The top of the log should rest in the pocket on the back log.

W415-0381 / H / 12.07.07

Image 21
Contents W415-0381 / H $10.00 BGD42 Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty General Instructions General InformationCare of GLASS, and Plated Parts Installation Overview Venting Lengths VentingMinimum AIR Terminal Location Clearances Special Vent Installations Typical Vent InstallationsVertical Termination Venting Application Flow ChartHorizontal Termination DefinitionsElbow Vent Length Values Formula 1 HT 4.2 VT Formula 2 HT + VT 24.75 feet Simple venting confi gurations Vertical TerminationFormula 1 HT 3VT Formula 2 HT + VT 40 feet Horizontal Installation Installation Wall and Ceiling ProtectionSee Figure Using Flexible Vent ComponentsFireplace Vent Connection Using Rigid Vent ComponentsGAS Installation Vertical Venting InstallationOptional Wall Switch Installation Restricting Vertical VentsFraming Mobile Home InstallationTAB Nailing TAB InstallationFinishing L42 Louvre InstallationPorcelain Reflective Panels Logo PlacementOptional FAN Installation Optional Blower InstallationCharcoal Embers VermiculiteMaintenance Operation / MaintenanceGD36 Thermostatic Sensor Control Operating InstructionsPilot Burner Adjustment AdjustmentsFlame Characteristics Venturi AdjustmentReplacements Replacement PartsAccessories W415-0381 / H Symptom Problem Test Solution Trouble Shooting GuideFlames are very ag Door is ajar