CHARCOAL EMBERS
Randomly place the charcoal embers along the front and sides of the log support tray in a realistic manner. Fine dust found in the bottom of the bag should not be used.
VERMICULITE
Sprinkle vermiculite around the charcoal embers.
Note: Both charcoal embers and vermiculite are not to be placed on the burner.
5.Place the bottom of the right crossover log
CHARCOAL LUMPS
Place the lumps between the logs in a realistic manner taking care not to block any of the burner ports.
OPTIONAL BLOWER INSTALLATION
INSTALLATION TO BE DONE
BY A QUALIFIED INSTALLER and must be electrically con- nected and grounded in ac-
cordance with local codes. In the absence of local codes, use the current CSA C22.1
CANADIAN ELECTRICAL CODE in Canada or the
ANSI/NFPA 70 NATIONAL ELECTRICAL
CODE in the United States
FIGURE 44
If the fireplace was not previously equipped with a blower: route a grounded
At this point, it must be strain relieved and insulated.
The three slots on the blower mount- ing bracket allow ease of adjustment when attaching the blower. For a quiet running blower, do not allow the as- sembly to sit on the fi rebox base.
Slide the vibration reducing pad (A) into the clip (C)
and up against the threaded stud (B) at the other end. The blower must be able to be positioned entirely onto the pad.
Tilt the blower onto its side. Slide it past the controls and into the clip
(C). Secure to the threaded stud using the lock washer and wing
nut provided. |
|
|
|
|
Ensure that the |
|
|
|
|
blower does | B |
|
|
|
not touch the |
|
|
| |
fi replace base |
|
| C | |
or the fi rebox. | A |
| ||
|
| |||
| FIGURE 46 |
| FIGURE 47 |
|
Attach the connectors from the black and white wires to the thermodisc and secure the thermodisc bracket to the securing stud at the bottom left of the unit using a lock washer and wing nut. Ensure that the thermodisc touches the fi rebox wall.
Attach the connectors from the black and red wires to the blower.
Attach and secure the variable speed switch using the nut provided. Plug the harness cord into the receptacle.
FIGURE 48
The wire harness provided in this kit is a universal harness. When installed, ensure that any excess wire is contained, preventing it from making contact with moving or hot objects.
Because the blower is thermally activated, when turned on, it will automatically start approxi- mately 10 minutes after lighting the fireplace and will run for ap- proximately
off. Use of the fan increases the output of heat.
Drywall dust will penetrate into the blower bearings, causing irreparable damage. Care must be taken to prevent drywall dust from coming into contact with the blower or its compartment. Any damage resulting from this condition is not covered by the warranty policy.
OPTIONAL FAN INSTALLATION
ELECTRICAL INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER and must be connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 CA-
NADIAN ELECTRICAL CODE in Canada or
the ANSI/NFPA 70 NATIONAL ELECTRI- CAL CODE in the United States.
To safely install the fan, turn off
the electricity fi rst. |
|
If the fireplace was not previ- | FIGURE 50 |
ously equipped with a fan: route |
|
a grounded
cable to the junction box. At this point, it must be strain relieved and insulated.
The wire harness provided in this kit is a | FIGURE 51 |
universal harness. When installed, ensure |
|
that any excess wire is contained, prevent- |
|
ing it from making contact with moving or |
|
hot objects. |
|
To ease installation of the fan, remove the |
|
hinge screen and valve control door (lower |
|
louvres) from the base of the fi replace. |
|
Position the vibration reducing pad into the clip and onto the threaded stud at the other
end, piercing a hole into the pad. The fan assembly must be able to be positioned entirely onto the pad.
Slide the fan assembly past the controls and into the clip. Secure using the lock washer and nut provided.
Plug the harness cord into the receptacle.