FIGURE 49
FIGURE 45

22

CHARCOAL EMBERS

Randomly place the charcoal embers along the front and sides of the log support tray in a realistic manner. Fine dust found in the bottom of the bag should not be used.

VERMICULITE

Sprinkle vermiculite around the charcoal embers.

Note: Both charcoal embers and vermiculite are not to be placed on the burner.

5.Place the bottom of the right crossover log (W135-0302)onto the stud on the right side of the log support. The top of the log should rest in the pocket on the left crossover log (W135-0300).

CHARCOAL LUMPS

Place the lumps between the logs in a realistic manner taking care not to block any of the burner ports.

OPTIONAL BLOWER INSTALLATION

INSTALLATION TO BE DONE

BY A QUALIFIED INSTALLER and must be electrically con- nected and grounded in ac-

cordance with local codes. In the absence of local codes, use the current CSA C22.1

CANADIAN ELECTRICAL CODE in Canada or the

ANSI/NFPA 70 NATIONAL ELECTRICAL

CODE in the United States

FIGURE 44

If the fireplace was not previously equipped with a blower: route a grounded 2-wire, 60hz power cable to the receptacle / junction box.

At this point, it must be strain relieved and insulated.

The three slots on the blower mount- ing bracket allow ease of adjustment when attaching the blower. For a quiet running blower, do not allow the as- sembly to sit on the fi rebox base.

Slide the vibration reducing pad (A) into the clip (C)

and up against the threaded stud (B) at the other end. The blower must be able to be positioned entirely onto the pad.

Tilt the blower onto its side. Slide it past the controls and into the clip

(C). Secure to the threaded stud using the lock washer and wing

nut provided.

 

 

 

 

Ensure that the

 

 

 

 

blower does

B

 

 

 

not touch the

 

 

 

fi replace base

 

 

C

or the fi rebox.

A

 

 

 

 

FIGURE 46

 

FIGURE 47

 

Attach the connectors from the black and white wires to the thermodisc and secure the thermodisc bracket to the securing stud at the bottom left of the unit using a lock washer and wing nut. Ensure that the thermodisc touches the fi rebox wall.

Attach the connectors from the black and red wires to the blower.

Attach and secure the variable speed switch using the nut provided. Plug the harness cord into the receptacle.

FIGURE 48

The wire harness provided in this kit is a universal harness. When installed, ensure that any excess wire is contained, preventing it from making contact with moving or hot objects.

Because the blower is thermally activated, when turned on, it will automatically start approxi- mately 10 minutes after lighting the fireplace and will run for ap- proximately 30-45 minutes after the fireplace has been turned

off. Use of the fan increases the output of heat.

Drywall dust will penetrate into the blower bearings, causing irreparable damage. Care must be taken to prevent drywall dust from coming into contact with the blower or its compartment. Any damage resulting from this condition is not covered by the warranty policy.

OPTIONAL FAN INSTALLATION

ELECTRICAL INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER and must be connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 CA-

NADIAN ELECTRICAL CODE in Canada or

the ANSI/NFPA 70 NATIONAL ELECTRI- CAL CODE in the United States.

To safely install the fan, turn off

the electricity fi rst.

 

If the fireplace was not previ-

FIGURE 50

ously equipped with a fan: route

 

a grounded 2-wire, 60hz power

cable to the junction box. At this point, it must be strain relieved and insulated.

The wire harness provided in this kit is a

FIGURE 51

universal harness. When installed, ensure

 

that any excess wire is contained, prevent-

 

ing it from making contact with moving or

 

hot objects.

 

To ease installation of the fan, remove the

 

hinge screen and valve control door (lower

 

louvres) from the base of the fi replace.

 

Position the vibration reducing pad into the clip and onto the threaded stud at the other

end, piercing a hole into the pad. The fan assembly must be able to be positioned entirely onto the pad.

Slide the fan assembly past the controls and into the clip. Secure using the lock washer and nut provided.

Plug the harness cord into the receptacle.

W415-0381 / H / 12.07.07

Image 22
Contents W415-0381 / H $10.00 BGD42 Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty General Information General InstructionsCare of GLASS, and Plated Parts Installation Overview Venting Venting LengthsMinimum AIR Terminal Location Clearances Typical Vent Installations Special Vent InstallationsVenting Application Flow Chart Vertical TerminationDefinitions Horizontal TerminationElbow Vent Length Values Formula 1 HT 4.2 VT Formula 2 HT + VT 24.75 feet Vertical Termination Simple venting confi gurationsFormula 1 HT 3VT Formula 2 HT + VT 40 feet Installation Wall and Ceiling Protection Horizontal InstallationUsing Flexible Vent Components See FigureUsing Rigid Vent Components Fireplace Vent ConnectionOptional Wall Switch Installation Vertical Venting InstallationGAS Installation Restricting Vertical VentsMobile Home Installation FramingNailing TAB Installation TABL42 Louvre Installation FinishingLogo Placement Porcelain Reflective PanelsCharcoal Embers Optional Blower InstallationOptional FAN Installation VermiculiteGD36 Thermostatic Sensor Control Operation / MaintenanceMaintenance Operating InstructionsFlame Characteristics AdjustmentsPilot Burner Adjustment Venturi AdjustmentReplacement Parts ReplacementsAccessories W415-0381 / H Trouble Shooting Guide Symptom Problem Test SolutionFlames are very ag Door is ajar