Napoleon Grills BGD38PT, BGD38NT Finishing, Door Removal & Installation L38 Louvre Installation

Page 18

18

FINISHING

DOOR REMOVAL & INSTALLATION

L38 LOUVRE INSTALLATION

Lift up and remove the upper

FIGURE 35

louvres. Open the valve control

 

 

door. Release the top and bot-

 

tom door latches, located at the

 

right side of the door.

 

To close the door, repeat in re-

 

verse order.

 

The door latch holes are elongated for door levelling. To level the door may need to be lifted up at the right side before latching to ensure the door is level.

GVFL LOUVRE INSTALLATION

FIGURE 37 a-c

B

A

Remove the pro- tective plastic wrap from the louvres and install as illus- trated.

Clip each upper louvre into a slot on the louvre bracket. Ensure that the

louvres are centered within the opening.

HINGE

SCREEN

LOUVRE

BRACKET

FIGURE 36a

UPPER LOUVRE INSTALLATION

C

A CLIPS

HOOD

FIGURES37a-d

FIGURE 36b: LOWER LOUVRE ASSEMBLY

FLANGE

Attach the hood by pressing the top flange into the clips along the top of the louvre opening. Secure using a screw through the centre slot.

Secure the lower louvre assembly to the lip of the fireplace base as shown.

Position the hinge screen into place and with the control door open, secure to the firebox using three screws.

C E N T R E

S L O T

B

C

HINGE

CLIP

S L O T

TA B

S L O T

UPPER LOUVRES

Insert the louvre tabs into the slots located at the top left and right corners of the unit.

LOWER LOUVRES

Insert the hinge clips into the slots located at the bottom left and right corners of the unit.

To remove the louvres, pull the back tabs of the clips forward, while pushing the louvre assem- bly back. Lift the clip.

W415-0244 / A / 05.15.03

Image 18
Contents Direct Vent Millivolt System Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty General Instructions General InformationCare of GLASS, and Plated Parts Venting Venting LengthsAIR Terminal Installations Typical Vent Installations Special Vent InstallationsVenting Application Flow Chart Horizontal Termination VerticalTOP Exit / Horizontal Termination DefinitionsElbow Vent Length Values Formula 1 HT 4.2 VT TOP Exit Vertical Termination 90 V1 H3 H1 290 H Installation Wall and Ceiling Protection Horizontal InstallationVertical Installation Using Flexible Vent Components Horizontal AIR Terminal InstallationUsing Rigid Vent Components Fireplace Vent ConnectionVertical Venting Installation GAS InstallationFraming Mobile Home InstallationMantle Installation Nailing TabsDoor Removal & Installation L38 Louvre Installation Gvfl Louvre InstallationFinishing Charcoal Embers LOG PlacementLogo Placement Glowing EmbersOptional Blower Installation WhiteOptional FAN Installation GD36 Thermostatic Sensor ControlOperation / Maintenance MaintenanceOperating Instructions Adjustments Pilot Burner AdjustmentVenturi Adjustment Replacements Replacement PartsAccessories W415-0244 / a Trouble Shooting Guide Symptom Problem Test SolutionDo not Clean Glass When HOT Fireplace Service History