Napoleon Grills BGD38NT TOP Exit / Horizontal Termination, Definitions, Elbow Vent Length Values

Page 9

DEFINITIONS

for the following symbols used in the venting calcula- tions and examples are:

>- greater than

>- equal to or greater than < - less than

< - equal to or less than

HT - total of both horizontal vent lengths (HR) and offsets (HO) in feet

HR - combined horizontal vent lengths in feet

HO - offset factor: .03(total degrees of offset - 90°*) in feet

VT - combined vertical vent lengths in feet

9

ELBOW VENT LENGTH VALUES

 

feet

inches

0.03

0.5

15°

0.45

6.0

30°

0.9

11.0

45°

1.35

16.0

90°*

2.7

32.0

*the first 90° offset has a zero value and is shown in the formula as -90°

TOP EXIT / HORIZONTAL TERMINATION

when (HT) < (VT)

For vent configurations requiring more than one 90° el-

Simple venting configuration (only one 90° elbow)

bow, the following formulas apply:

 

Formula 1: HT < VT

 

 

 

 

 

 

Formula 2: H

 

+ V

< 40 feet

H

 

 

T

T

90°

 

Example 1:

 

 

 

2

 

 

 

 

 

FIGURE 5

V2

FIGURE 6

See graph to determine the required vertical rise VT for the required horizontal run HT.

90°

90° H1

V1

VERTICAL

RISE IN

FEET

VT

HORIZONTAL VENT RUN PLUS OFFSET IN FEET HT

The shaded area within the lines represents acceptable values for HT and VT .

V1

=

3 ft

V2

=

8 ft

VT

= V1 + V2 = 3 + 8 = 11 ft

H1

=

2.5 ft

H2

=

2 ft

HR

= H1 + H2 = 2.5 + 2 = 4.5 ft

HO

= .03(three 90° elbows - 90°) = .03(270° - 90°) = 5.4 ft

HT

= HR + HO = 4.5 + 5.4 = 9.9 ft

HT + VT = 9.9 + 11 = 20.9 ft

Formula 1: HT < VT 9.9 < 11

Formula 2: HT + VT < 40 feet

20.9 < 40

Since both formulas are met, this vent configuration is ac- ceptable.

W415-0244 / A / 05.15.03

Image 9
Contents Direct Vent Millivolt System Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty General Instructions General InformationCare of GLASS, and Plated Parts Venting Lengths VentingAIR Terminal Installations Special Vent Installations Typical Vent InstallationsHorizontal Termination Vertical Venting Application Flow ChartTOP Exit / Horizontal Termination DefinitionsElbow Vent Length Values Formula 1 HT 4.2 VT 90 V1 H3 H1 2 TOP Exit Vertical Termination90 H Installation Wall and Ceiling Protection Horizontal InstallationVertical Installation Horizontal AIR Terminal Installation Using Flexible Vent ComponentsFireplace Vent Connection Using Rigid Vent ComponentsGAS Installation Vertical Venting InstallationMantle Installation Mobile Home InstallationFraming Nailing TabsDoor Removal & Installation L38 Louvre Installation Gvfl Louvre InstallationFinishing Logo Placement LOG PlacementCharcoal Embers Glowing EmbersWhite Optional Blower InstallationGD36 Thermostatic Sensor Control Optional FAN InstallationOperation / Maintenance MaintenanceOperating Instructions Adjustments Pilot Burner AdjustmentVenturi Adjustment Replacements Replacement PartsAccessories W415-0244 / a Symptom Problem Test Solution Trouble Shooting GuideDo not Clean Glass When HOT Fireplace Service History