Napoleon Grills BGD38NT, BGD38PT manual Venting Lengths

Page 5

5

FIGURE 1

VENTING

VENTING LENGTHS

Use only Wolf Steel or Simpson Dura-Vent Model DV-GS venting components. Minimum and maximum vent lengths, for both horizontal and vertical installations, and air termi- nal locations for either system are set out in this manual and must be adhered to. For Simpson Dura-Vent, follow the installation procedure provided with the venting com- ponents.

When using Wolf Steel venting components, use only ap- proved Wolf Steel rigid / flexible components with the fol- lowing termination kits: WALL TERMINAL KIT GD422, or 1/12 TO 7/12 PITCH ROOF TERMINAL KIT GD410, 8/12 TO 12/12 ROOF TERMINAL KIT GD411, FLAT ROOF TERMI- NAL KIT GD412 or PERISCOPE KIT GD401 (for wall pen- etration below grade). With flexible venting, in conjunction with the various terminations, use either the 5 foot vent kit GD420 or the 10 foot vent kit GD430.

Wolf Steel rigid and flexible venting systems must not be combined.

Wolf Steel and Simpson Dura-Vent venting systems must not be combined.

These vent kits allow for either horizontal or vertical venting of the fireplace. FIGURES 3a, & 5a. The maximum allow- able horizontal run is 20 feet. The maximum allowable ver- tical vent length is 40 feet. The maximum number of 5" vent connections is two horizontally or three vertically (exclud- ing the fireplace and the air terminal connections) when using aluminum flexible venting.

For optimum flame appearance and fireplace perform- ance, keep the vent length and number of elbows to a minimum.

The air terminal must remain unobstructed at all times. Examine the air terminal at least once a year to verify that it is unobstructed and undamaged.

Purge all gas lines with the glass door of the fireplace open. Assure that a continuous gas flow is at the burner before closing the door.

Under extreme vent configurations, allow several minutes (5-15) for the flame to stabilize after ignition.

Eight (8") inches is the minimum bend radius allowed for the 8" diameter flexible liner.

For optimum performance it is recommended that all horizontal runs have a 1 inch rise per foot when using Napoleon flexible vent components.

A terminal shall not terminate directly above a sidewalk or paved driveway which is located between two sin- gle family dwellings and serves both dwellings. Local codes or regulations may require different clearances. Do not allow the inside liner to bunch up on horizontal or vertical runs and elbows. Keep it pulled tight. A 1¼" air gap all around between the inner liner and outer liner is required for safe operation. Use a firestop when pen- etrating interior walls, floor or ceiling.

Minimum clearance to combustible con- struction from fireplace and vent sur- faces:

sides, back, bottom and top of the unit

0 inch

recessed depth

18 inches

top, sides and bottom of the vent pipe

1 inch

Horizontal runs may have a 0 inch rise per foot in all cases using SIMPSON DURA-VENT or NAPOLEON RIGID OR FLEXIBLE venting components when vent- ing as illustrated in Figures 3, and 4.

Only a clearance to combustibles of 1" all around the vent pipe is required.

W415-0244 / A / 05.15.03

Image 5
Contents Direct Vent Millivolt System Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty Care of GLASS, and Plated Parts General InstructionsGeneral Information Venting Lengths VentingAIR Terminal Installations Special Vent Installations Typical Vent InstallationsHorizontal Termination Vertical Venting Application Flow ChartElbow Vent Length Values TOP Exit / Horizontal TerminationDefinitions Formula 1 HT 4.2 VT 90 V1 H3 H1 2 TOP Exit Vertical Termination90 H Vertical Installation Installation Wall and Ceiling ProtectionHorizontal Installation Horizontal AIR Terminal Installation Using Flexible Vent ComponentsFireplace Vent Connection Using Rigid Vent ComponentsGAS Installation Vertical Venting InstallationMantle Installation Mobile Home InstallationFraming Nailing TabsFinishing Door Removal & Installation L38 Louvre InstallationGvfl Louvre Installation Logo Placement LOG PlacementCharcoal Embers Glowing EmbersWhite Optional Blower InstallationGD36 Thermostatic Sensor Control Optional FAN InstallationOperating Instructions Operation / MaintenanceMaintenance Venturi Adjustment AdjustmentsPilot Burner Adjustment Accessories ReplacementsReplacement Parts W415-0244 / a Symptom Problem Test Solution Trouble Shooting GuideDo not Clean Glass When HOT Fireplace Service History