Napoleon Grills BGD38PT, BGD38NT manual 90 H

Page 12

12

TOP EXIT VERTICAL TERMINATION

when (Ht) > (Vt)

Simple venting configurations

See graph to determine the required vertical rise VT for the required horizontal run HT.

FIGURE 12

For vent configurations requiring elbows, the following for- mulas apply:

VT

= V1 + V2 + V3 = 2 + 1 + 1.5 = 4.5 ft

H1

=6 ft

H2

=2 ft

HR

= H1 + H2 = 6 + 2 = 8 ft

HO

= .03(four 90° elbows - 90°)

 

= .03(90 + 90 + 90 + 90 - 90) = 8.1 ft

HT

= HR + HO = 8 + 8.1 = 16.1 ft

HT + VT = 16.1 + 4.5 = 20.6 ft

Formula 1: HT < 3VT

3VT = 3 x 4.5 = 13.5 ft

16.1 > 13.5

Since this formula is not met, this vent configuration is unacceptable.

Formula 2: HT + VT < 40 feet

20.6 < 40

Since only formula 2 is met, this vent configuration is unac- ceptable and a new fireplace location or vent configuration will need to be established to satisfy both formulas.

MAXIMUM

VERTICAL

RISE IN

FEET

VT

HORIZONTAL VENT RUN PLUS OFFSET IN FEET HT

The shaded area within the lines represents acceptable values for HT and VT .

Formula 1: HT < 3VT

Formula 2: HT + VT < 40 feet

Example 5:

V1

=2 ft

V2

=1 ft

V3

=1.5 ft

90°

 

90°

 

 

 

 

V3

V

 

H2

1

H1

V2

 

90°

 

 

 

 

90°

FIGURE 13

Example 6:

V1

=1.5 ft

 

V2

=5 ft

 

VT

= V1 + V2

= 1.5 + 5 = 6.5 ft

 

90°

V2

 

H3 45°

90° H

 

 

2

90°

 

V1

H

H

1

 

4

FIGURE 14

H1

=1 ft

H2

=1 ft

H3

=1 ft

H4

=10.75 ft

HR

= H1 + H2 + H3 + H4 = 1 + 1 + 1 + 10.75 = 13.75 ft

HO

= .03(four 90° elbows + one 45° elbow - 90°)

 

= .03(90 + 90 + 90 + 90 + 45 - 90) = 9.45 ft

HT

= HR + HO = 13.75 + 9.45 = 23.2 ft

HT + VT = 23.2 + 6.5 = 29.7 ft

Formula 1: HT < 3VT

3VT = 3 x 6.5 = 19.5 ft

19.5 = 19.5

Formula 2: HT + VT < 40 feet

29.7 < 40

Since both formulas are met, this vent configuration is ac- ceptable.

W415-0244 / A / 05.15.03

Image 12
Contents Direct Vent Millivolt System Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty General Instructions General InformationCare of GLASS, and Plated Parts Venting Venting LengthsAIR Terminal Installations Typical Vent Installations Special Vent InstallationsVenting Application Flow Chart Horizontal Termination VerticalTOP Exit / Horizontal Termination DefinitionsElbow Vent Length Values Formula 1 HT 4.2 VT TOP Exit Vertical Termination 90 V1 H3 H1 290 H Installation Wall and Ceiling Protection Horizontal InstallationVertical Installation Using Flexible Vent Components Horizontal AIR Terminal InstallationUsing Rigid Vent Components Fireplace Vent ConnectionVertical Venting Installation GAS InstallationMobile Home Installation Mantle InstallationFraming Nailing TabsDoor Removal & Installation L38 Louvre Installation Gvfl Louvre InstallationFinishing LOG Placement Logo PlacementCharcoal Embers Glowing EmbersOptional Blower Installation WhiteOptional FAN Installation GD36 Thermostatic Sensor ControlOperation / Maintenance MaintenanceOperating Instructions Adjustments Pilot Burner AdjustmentVenturi Adjustment Replacements Replacement PartsAccessories W415-0244 / a Trouble Shooting Guide Symptom Problem Test SolutionDo not Clean Glass When HOT Fireplace Service History