Vanguard Heating VMH26PRA Inspecting Burners, GWMT1 Wall Mounted Thermostat Optional

Page 20

® VMH26PRA

COMPACT CLASSIC HEARTH FIREPLACE

OPERATING

FIREPLACE

Continued

IMPORTANT: This remote control has been specially engineered to take an air temperature sample every 5.5 minutes in the auto mode. It will not respond immediately to the tempera- ture setting being turned up or down.

IMPORTANT: The hand-held remote control unit must be near the heater. Do not keep the hand-held remote control unit too close to the heater. The thermostat on the hand-held re- mote control unit will heat up too quickly and turn the heater off.

3.To turn the burner off, press the AUTO/ON/OFF button until OFF lights. The pilot will remain lit.

IMPORTANT: To turn the pilot off, manually turn the control knob on the heater to the OFF position.

Shows

Increases Room

Temperature in

Temperature

AUTO Mode

Setting

 

Decreases

Room

Temperature

in AUTO

Mode

The Log Heater

Turns Burners

will Automatically

On or Off and

Cycle between

Allows You to

Pilot and the Heat

Choose the

Setting that has

Auto Setting

been Selected

 

Figure 39 - Thermostat Hand-Held

Remote Control Unit Selections

(GHRCTA Series Only)

GWMT1 WALL

MOUNTED

THERMOSTAT

(OPTIONAL)

Make sure the heater switch is on AUTO and set the temperature adjustment on wall thermostat to the desired setting. The thermostat has been electronically calibrated at the factory and requires no adjustment or leveling.

Upon installation, the thermostat must be allowed to stabilize at room tempera- ture for a minimum of 30 minutes for proper operation. See installation instruc- tions on pages 16 and 17 of this manual.

GWMS2 WALL

MOUNTED SWITCH

(OPTIONAL)

Make sure the heater switch is on AUTO. This wall switch works just like the con- ventional light switch. Flip the switch up for on and down for off.

Note: Make sure that this switch is not in a position to be mistaken for a light switch. This may result in the heater being inad- vertently turned on without the proper precautions being taken. See installation instructions on page 17 of this manual.

OPERATING BLOWER

This blower has three settings: ON, OFF, and AUTO. In the ON position, the blower will operate constantly. In the OFF posi- tion, the blower will not operate. In the AUTO position, the blower will start when the thermostat senses a sufficient increase in firebox temperature.

Note: Your fireplace and thermostat blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases.

Note: It is safe to operate fireplace with blower turned off. However, the blower helps distribute heated air from the fireplace.

Auto/Off/On Switch

Figure 40 - Auto/Off/On Switch

INSPECTING

BURNERS

Check pilot flame pattern and burner flame patterns often.

PILOT FLAME PATTERN

Figure 41 shows a correct pilot flame pat- tern. Figure 42 shows an incorrect pilot flame pattern. The incorrect pilot flame is not properly heating the thermocouple. When the thermocouple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown in Figure 42.

turn heater off (see To Turn Off Gas to Appliance, page 19)

see Troubleshooting, pages 22 through 24

Pilot Burner

Thermocouple

Figure 41 - Correct Pilot Flame Pattern

Pilot Burner

Thermocouple

Figure 42 - Incorrect Pilot Flame Pattern

For more information, visit www.desatech.com

20

107034

Image 20
Contents VENT-FREE PROPANE/LP GAS What to do if YOU Smell GASSafety Information Compact Classic Hearth FireplaceProduct Features Remote Control AccessoriesLocal Codes UnpackingAssembly Installing LogAssembling Fireplace Assembling HoodAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installation Installation ItemsCheck GAS Type Locating FireplaceBUILT-IN Fireplace Installation Rough Opening for Installing in WallAssembling Brass Trim Brass trim shipped with mantel Optional Mantel InstallationMantel Clearances for Built-In Installation Removing Upper Louver Assembly Installing Blower Accessory GA3400TInstalling Blower Assembly For Built-In Installation Extension CordFor attaching base to solid floors concrete or masonry Connecting to GAS SupplyAttaching Wood Base to Solid Floor Connecting Fireplace to GAS Supply Installation Items NeededChecking GAS Connections Pressure Testing Fireplace Gas ConnectionsPressure Testing Gas Supply Piping System Optional Wireless HAND- Held Remote Control Accessories Installing ReceiverInstalling 9-Volt Battery in Hand- Held Remote Control Unit Wire harness provided in the fireplace hardware packOptional Wall Switch GWMS2 Lighting Instructions For Your Safety Read Before LightingOperating Fireplace Optional Remote Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance GWMS2 Wall Mounted Switch Optional Inspecting BurnersGWMT1 Wall Mounted Thermostat Optional Operating BlowerCleaning and Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleInspecting Burner Burner Flame PatternTroubleshooting Observed Problem Possible CauseLation requirements Pane/LP gas companyGas odor even when control knob is in OFF Vice personCarpet, etc. See Important state Is running Ment above PositionSpecifications Replacement PartsService Hints Technical ServiceIllustrated Parts Breakdown VMH26PRA4Parts List VMH26PRAAccessories Wall Mounted Thermostat KIT GWMT1 Wall Mounted Switch KIT GWMS2Cleaning KIT CCK Warranty Information International