Vanguard Heating VMH26PRA Local Codes, Product Features, Remote Control Accessories, Unpacking

Page 3

OWNER’S MANUAL

SAFETY

INFORMATION

Continued

16.Operating fireplace above elevations of 4,500 feet could cause pilot outage.

17.Do not operate fireplace if any log is broken. Do not operate fireplace if a log is chipped (dime-sized or larger).

18.To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. capacity.

LOCAL CODES

Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANS Z223.1, also known as NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

PRODUCT

FEATURES

SAFETY PILOT

This fireplace has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free room fireplaces. The ODS/ pilot shuts off the fireplace if there is not enough fresh air.

PIEZO IGNITION SYSTEM

This fireplace has a piezo ignitor. This sys- tem requires no matches, batteries, or other sources to light fireplace..

REMOTE CONTROL ACCESSORIES

There are four optional remote controls that can be purchased separately for this log heater:

hand-held ON/OFF remote

hand-held thermostat remote

wall mounted thermostat

wall mounted ON/OFF switch

See Accessories, pages 28 and 29.

UNPACKING

1.Remove log box and fireplace from carton. IMPORTANT: The fireplace hood is inside the cardboard protective end wrap on the left side of fireplace (as viewed from front). A decal is on the outside of the cardboard end wrap stating hood is enclosed (see Figure 2).

2.Remove hood from cardboard protec- tive end wrap as shown in Figure 2.

3.Remove all protective packaging ap- plied to fireplace for shipment.

4.Make sure your fireplace includes one hardware packet.

5.Check fireplace for any shipping damage. If fireplace is damaged, promptly inform dealer where you bought fireplace.

Hood Enclosed

IMPORTANT:

THIS PACKAGE CONTAINS A

Decal

 

 

 

FIREPLACE HOOD. UNWRAP

 

 

 

 

CARTON AND REMOVE HOOD

 

 

 

BEFORE DISCARDING

 

 

 

PROTECTIVE PACKAGING.

 

 

 

Cardboard

 

 

 

Protective

 

 

 

Fireplace

 

 

 

 

 

 

End Wrap

PRODUCT IDENTIFICATION

Fireplace

Cabinet

Screen

Log Set

 

Control

Remote Control

 

Knob

(Optional)

Selector Switch

Ignitor Button

 

(Optional)

 

 

 

Figure 1 - Vent-Free Natural Gas Compact Fireplace

2

1

Hood

Figure 2 - Removing Fireplace Hood

107034

3

For more information, visit www.desatech.com

Image 3
Contents What to do if YOU Smell GAS VENT-FREE PROPANE/LP GASCompact Classic Hearth Fireplace Safety InformationUnpacking Product FeaturesRemote Control Accessories Local CodesAssembling Hood AssemblyInstalling Log Assembling FireplaceConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionAIR for Combustion Ventilation Determining FRESH-AIR Flow for Fireplace LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Locating Fireplace InstallationInstallation Items Check GAS TypeRough Opening for Installing in Wall BUILT-IN Fireplace InstallationOptional Mantel Installation Mantel Clearances for Built-In InstallationAssembling Brass Trim Brass trim shipped with mantel Installing Blower Accessory GA3400T Installing Blower AssemblyRemoving Upper Louver Assembly Extension Cord For Built-In InstallationConnecting to GAS Supply Attaching Wood Base to Solid FloorFor attaching base to solid floors concrete or masonry Installation Items Needed Connecting Fireplace to GAS SupplyPressure Testing Fireplace Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Wire harness provided in the fireplace hardware pack Optional Wireless HAND- Held Remote Control AccessoriesInstalling Receiver Installing 9-Volt Battery in Hand- Held Remote Control UnitOptional Wall Switch GWMS2 For Your Safety Read Before Lighting Operating FireplaceLighting Instructions Manual Lighting Procedure To Turn OFF GAS To ApplianceOptional Remote Operation Operating Blower GWMS2 Wall Mounted Switch OptionalInspecting Burners GWMT1 Wall Mounted Thermostat OptionalBurner Flame Pattern Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Inspecting BurnerObserved Problem Possible Cause TroubleshootingPane/LP gas company Lation requirementsPosition Gas odor even when control knob is in OFFVice person Carpet, etc. See Important state Is running Ment aboveTechnical Service SpecificationsReplacement Parts Service HintsVMH26PRA4 Illustrated Parts BreakdownVMH26PRA Parts ListAccessories Wall Mounted Switch KIT GWMS2 Cleaning KIT CCKWall Mounted Thermostat KIT GWMT1 International Warranty Information