Desa (V)JM36, (V)JM50, (V)JM42 Installing Brick AO or AR, Brick Installation for Model VJM36

Page 14

BRICK INSTALLATION

Continued

Install the bricks one at a time starting with the hearth panel followed by the rear panel and then the left or right panel. It is important to install the bricks in sequence. Note: The left and right panels have identical bricks. Please note, full size bricks are NOT stamped.

Use brick “AO” (JM42 and JM50 only) or “AR” (JM36 only) if an optional gas line is installed. Mount brick “AO” or “AR” as shown in Figure

20.It is important that the knockout hole is in its proper locations. The knockout hole on brick “AO” or “AR” should align with the hole on the brick housing.

Brick

Stamped

Letter

 

 

Location

Flanges

 

Brick Housing

Figure 20 - Installing Brick

INSTALLING BRICK "AO" OR "AR"

Use brick “AO” (JM42 and JM50 only) or “AR” (JM36 only) if an optional gas line is installed. Mount brick “AO” or “AR” as shown in Figure

21.It is important that the knockout hole is in its proper location. The knockout hole on brick “AO” or “AR” should align with the hole on the brick housing.

 

LEFT PANEL

 

D

FULL

FULL

B

CAN

 

 

AO

 

 

 

 

OR

 

 

 

 

AR

 

 

 

RIGHT PANEL

 

 

B

FULL

FULL

 

D

 

AN

 

C

D1510

 

 

 

 

 

AO

 

 

 

 

OR

 

 

 

 

AR

 

 

 

Figure 21 - Installing Brick “AO” or “AR”

BRICK INSTALLATION FOR MODEL (V)JM36

 

LEFT PANEL

REAR PANEL

RIGHT PANEL

P

 

Q

AH

 

AF

FULL

AG

FULL

AC

AF

FULL

AG

FULL

AC

AF

FULL

AG

 

 

AN

 

 

AP

 

 

 

OR

 

AI

 

Q

Q

AI

 

AH

Q

P

AE

C

FULL

C

 

AE

FULL

AF

D FULL

FULL

D

 

AC

FULL AG

AE

C

FULL

C

 

AE

FULL

AF

D FULL

FULL

D

 

AC

FULL AG

AE

C

FULL

C

 

AE

FULL

AF

AS

 

AL

AL

 

 

AS

AT

 

AG

 

 

 

 

 

 

 

 

AP

 

 

 

 

 

 

 

 

 

OR

 

**AR

 

G

FULL

G

 

**AR

 

H

FULL

FULL

H

 

**See instruction above before

I

FULL

FULL

FULL

I

installing brick "AR"

 

 

M

FULL

FULL

M

 

 

AB

 

L

 

L

 

L

AB

 

HEARTH PANEL

 

 

14

www.desatech.com

117541-01A

Image 14
Contents Save this Book Wood Burning Masonry Fireplaces with InsulationTable of Contents Safety InformationSpecifications Models VJM36 and JM36Models VJM42 and JM42 Specifications Models VJM50 and JM50Framing Selecting LocationMinimum Clearance to Combustibles Hearth Extension MantelsOptional Outside AIR KIT Model AK4/AK4F Venting InstallationAssembly and Installation Double Wall Chimney SystemUsing Elbow Offsets 30E-12DM Elbow SET onlyFirestop Spacers FS-10, 1100EFS-10DM for JM36 Penetrating the RoofFlashing Installation V6F-10DM or V12F-10DM Apply waterproof caulk aroundFoot Rule Optional GAS Line InstallationChase Installations Finishing the FireplaceBrick Installation Gas Line KnockoutInstalling Brick AO or AR Brick Installation for Model VJM36See instruction on page 14 before installing brick AO Brick Installation for Model VJM42Brick Installation for Model VJM50 See instruction on page 14 before install- ing brick AOBrick Matrix VJM36 Brick Matrix for Model VJM36Brick Matrix VJM42 Brick Matrix for Model VJM42Brick Matrix VJM50 Brick Matrix for Model VJM50To handle Installing Z-SHAPED Grate Retainer BracketGrouting Instructions Installing Door Frame Glass Door InstallationDoor Frame Assembly Installing Glass DoorsOutside AIR and Damper Handle Operation Operation Maintenance GuidelinesGlass Doors Technical Service Operating Damper HandleReplacement and Accessory Parts BI-FOLD Glass DoorNot a UPC
Related manuals
Manual 40 pages 9.16 Kb

(V)JM36, (V)JM50, (V)JM42 specifications

The Desa WCM-50J, WCM-36J, and WCM-42J are part of the (V)JM50 series and (V)JM36 series, renowned for their versatility and efficiency in various applications. These models are designed to meet the dynamic needs of modern users, providing reliable performance in multiple operating conditions.

One of the standout features of these models is their energy efficiency. Equipped with advanced thermal management systems, the WCM series optimizes power consumption while maintaining high output levels. This energy-efficient design not only reduces operational costs but also aligns with environmental sustainability practices, making them suitable for eco-conscious consumers.

In terms of technology, the WCM series integrates cutting-edge automation capabilities. These machines feature user-friendly interfaces that allow for easy programming and monitoring of operations. The intuitive controls enable users to adapt settings quickly to match specific requirements, enhancing productivity and minimizing downtime.

Additionally, the WCM-50J, WCM-36J, and WCM-42J models incorporate robust safety features to protect operators and equipment. Safety interlocks and emergency-stop mechanisms are standard, ensuring that the machines are safe to operate in diverse working environments. The durability of the build materials used in these models contributes to their long lifespan, reducing the need for frequent maintenance or replacements.

The compact design of the WCM series enhances their adaptability. Whether in a crowded workshop or a spacious industrial setting, these machines can be integrated seamlessly. Their lightweight construction does not compromise stability, allowing for easy repositioning as needed without sacrificing safety or performance.

Customer feedback highlights the exceptional reliability of the WCM series under various workloads. Users appreciate the consistent quality of output, which is essential for maintaining high standards in production and service delivery.

Overall, the Desa WCM-50J, WCM-36J, and WCM-42J, along with the (V)JM50 and (V)JM36 series, are ideal choices for those seeking advanced, efficient, and safe solutions in today’s competitive market. Their combination of innovative technology, user-friendly operation, and durability makes them a valuable investment for businesses aiming to enhance productivity and sustainability.