Desa (V)JM50, (V)JM42, (V)JM36 Selecting Location, Minimum Clearance to Combustibles, Framing

Page 6

FIREPLACE INSTALLATION

SELECTING LOCATION

To determine the safest and most efficient location for the fireplace, you must take into consideration the following guidelines:

1.The location must allow for proper clearances (see Figures 1 and 2).

2.Consider a location where the fireplace will not be affected by drafts, air conditioning ducts, windows or doors.

3.A location that avoids the cutting of joists or roof rafters will make installation easier.

4.An outside air kit is available with this fireplace (see Optional Outside Air Kit on page 8).

MINIMUM CLEARANCE TO

COMBUSTIBLES

Back and sides of fireplace

1 1/2" minimum*

Front of fireplace

48" minimum

Floor**

0" minimum

Perpendicular wall to opening

18" minimum

 

12" min. JM36

Top spacers

0" minimum

Mantel clearances

see Mantels, page 7

Chimney outer pipe surface

2" minimum

 

1" min. JM36

*Not required at nailing flanges ** See step 2 of Framing

FRAMING

1.Frame the opening for the fireplace using the dimensions shown in Figures 1 and 2.

2.If the fireplace is to be installed directly on carpeting, tile (other than ceramic) or any combustible material other than wood floor- ing, the fireplace must be installed upon a metal or wood panel extending the full width and depth of the fireplace.

3.Set the fireplace directly in front of this open- ing and slide the unit back until the nailing flanges touch the side framing.

4.Check the level of the fireplace and shim with sheet metal if necessary.

5.Before securing fireplace to prepared framing, the ember protector (provided) must be placed between the hearth extension (not supplied) and under the bottom front edge of the fire- place to protect against glowing embers falling through. If the fireplace is to be installed on a raised platform, a Z-type ember protector (not supplied) must be fabricated to fit your required platform height. The ember protector should extend under the fireplace a minimum of 1 1/2". The ember protector should be made of galvanized sheet metal (28 gauge minimum to prevent corrosion.

6.Using screws or nails, secure the fireplace to the framing through flanges located on the sides of the fireplace.

WARNING: Do not pack re- quired air spaces with insulation or other materials.

Minimum/Maximum Chimney Height for Residential Installation

The minimum height of the chimney, measured from the base of the fireplace to the flue gas outlet of the termination, is 16 feet for straight flue or a flue with one elbow set. The maximum distance between elbows is 6 feet. For systems with two

59.250 (50")

51.250 (42") 45.250 (36")

67.125

58.125

30.125 28.250 (36")

elbow sets, the minimum height is 22 feet. The maximum height of any system is 50 feet. This measurement includes the fireplace, chimney sec-

Figure 1 - Framing Dimensions

tions and the height of the termination assembly at the level of the flue gas outlet (see Figure 15, page 11).

Minimum/Maximum Chimney Height for Outdoor Installation

The minimum height of the chimney, measured from the base of the fireplace to the flue gas outlet of the termination, is 9.5 feet (minimum of 4 feet

61.000 (36")

65.000 (42")

71.000 (50")

MAINTAIN 1 1/2"

CLEARANCE AT

SIDES AND BACK OF FIREPLACE

1 1/2" CLEARANCE

NOT REQUIRED AT

NAILING FLANGES

86.500 (36")

92.000 (42")

100.000 (50")

of chimney pipe sections required for outdoor installation).

Figure 2 - Corner Installation

6

www.desatech.com

117541-01A

Image 6
Contents Save this Book Wood Burning Masonry Fireplaces with InsulationTable of Contents Safety InformationSpecifications Models VJM36 and JM36Models VJM42 and JM42 Specifications Models VJM50 and JM50Selecting Location Minimum Clearance to CombustiblesFraming Hearth Extension MantelsOptional Outside AIR KIT Model AK4/AK4F Venting InstallationAssembly and Installation Double Wall Chimney SystemUsing Elbow Offsets 30E-12DM Elbow SET onlyFirestop Spacers FS-10, 1100EFS-10DM for JM36 Penetrating the RoofFlashing Installation V6F-10DM or V12F-10DM Apply waterproof caulk aroundFoot Rule Optional GAS Line InstallationChase Installations Finishing the FireplaceBrick Installation Gas Line KnockoutInstalling Brick AO or AR Brick Installation for Model VJM36See instruction on page 14 before installing brick AO Brick Installation for Model VJM42Brick Installation for Model VJM50 See instruction on page 14 before install- ing brick AOBrick Matrix VJM36 Brick Matrix for Model VJM36Brick Matrix VJM42 Brick Matrix for Model VJM42Brick Matrix VJM50 Brick Matrix for Model VJM50Installing Z-SHAPED Grate Retainer Bracket Grouting InstructionsTo handle Installing Door Frame Glass Door InstallationDoor Frame Assembly Installing Glass DoorsOperation Maintenance Guidelines Glass DoorsOutside AIR and Damper Handle Operation Technical Service Operating Damper HandleReplacement and Accessory Parts BI-FOLD Glass DoorNot a UPC
Related manuals
Manual 40 pages 9.16 Kb

(V)JM36, (V)JM50, (V)JM42 specifications

The Desa WCM-50J, WCM-36J, and WCM-42J are part of the (V)JM50 series and (V)JM36 series, renowned for their versatility and efficiency in various applications. These models are designed to meet the dynamic needs of modern users, providing reliable performance in multiple operating conditions.

One of the standout features of these models is their energy efficiency. Equipped with advanced thermal management systems, the WCM series optimizes power consumption while maintaining high output levels. This energy-efficient design not only reduces operational costs but also aligns with environmental sustainability practices, making them suitable for eco-conscious consumers.

In terms of technology, the WCM series integrates cutting-edge automation capabilities. These machines feature user-friendly interfaces that allow for easy programming and monitoring of operations. The intuitive controls enable users to adapt settings quickly to match specific requirements, enhancing productivity and minimizing downtime.

Additionally, the WCM-50J, WCM-36J, and WCM-42J models incorporate robust safety features to protect operators and equipment. Safety interlocks and emergency-stop mechanisms are standard, ensuring that the machines are safe to operate in diverse working environments. The durability of the build materials used in these models contributes to their long lifespan, reducing the need for frequent maintenance or replacements.

The compact design of the WCM series enhances their adaptability. Whether in a crowded workshop or a spacious industrial setting, these machines can be integrated seamlessly. Their lightweight construction does not compromise stability, allowing for easy repositioning as needed without sacrificing safety or performance.

Customer feedback highlights the exceptional reliability of the WCM series under various workloads. Users appreciate the consistent quality of output, which is essential for maintaining high standards in production and service delivery.

Overall, the Desa WCM-50J, WCM-36J, and WCM-42J, along with the (V)JM50 and (V)JM36 series, are ideal choices for those seeking advanced, efficient, and safe solutions in today’s competitive market. Their combination of innovative technology, user-friendly operation, and durability makes them a valuable investment for businesses aiming to enhance productivity and sustainability.