OPTIONAL OUTSIDE AIR KIT (MODEL AK4/AK4F)

The installation of an outside air kit should be per- formed during the rough framing of the fireplace due to the nature of it's location. Outside combus- tion air is accessed through a vented crawl space (AK4F) or through a sidewall (AK4).

CAUTION: Combustion air inlet ducts shall not terminate in attic space.

Secure to Collars with Metal Tape, Screws or Straps (Min. of 1/4" x 20" in size)

Air Inlet

Location

Must Allow

For Bushes

or Snow

LINEAL GAIN

PART NO.

DESCRIPTION

GAIN (IN)

Georgian

Fireplace

66 1/2"

12-12DM

Pipe Section

10 5/8"

12-12HT

 

 

18-12DM

Pipe Section

16 5/8"

18-12HT

 

 

24-12DM

Pipe Section

23 5/8"

24-12HT

 

 

36-12DM

Pipe Section

34 5/8"

36-12HT

 

 

48-12DM

Pipe Section

46 5/8"

48-12HT

 

 

RLT-12D

Round Termination

7 3/4"*

RLT-12HT

 

 

STL-12D

Square Chase-Top

7" to 15"*

with Slip Section

 

 

 

*The lineal gain for the terminations is mea- sured to the flue gas outlet height.

12" Galvanized

 

Outer Pipe

 

12

3

/8"

Hemmed

 

End

Stainless

 

Inner Pipe

 

Vented Crawl Space

(Check Local Codes

Before Installing in a

Vented Crawl Space)

Air Inlet Eyebrow

Vent Hood Required for Wall Installation

Figure 6 - Lineal Gain

ASSEMBLY AND INSTALLATION OF

DOUBLE WALL CHIMNEY SYSTEM

Figure 5 - Outside Air Kit

CHIMNEY PIPE

The DESA chimney system consists of 12, 18, 24, 36 and 48" snap-lock, double-wall pipe segments, planned for maximum adaptability to individual site requirements. Actual lengths gained after fitting overlaps must be taken into consideration (lineal gain) and are given in the lineal gain chart (see Figure 6). Lineal Gain is the actual mea- surable length of a part after two or more parts are connected. For Canada, use chimney parts designated "HT".

WARNING: The opening in the collar around the chimney at the top of the fireplace must not be obstructed.Neveruseblowninsula- tion to fill the chimney enclosure.

Each double wall chimney section consists of a

galvanized outer pipe, a stainless steel inner flue

pipe and a wire spacer. The pipe sections must be as-

sembled independently as the chimney is installed.

When connecting chimney directly to the fireplace,

the inner flue pipe section must be installed first with

the lanced side up. The outer pipe section can then

be installed over 5 the flue pipe section with the

hemmed end up. Press down on each pipe section

until the lances securely engage the hem on the fire-

place starter. The wire will assure the proper spacing

between the inner and outer pipe sections.

Continue to assemble chimney sections as outlined

above, making sure that both the inner and outer

pipe sections are locked together. When install-

ing double wall snap-lock chimney together, it is

important to assure the joint between the chimney

sections is locked. Check by pulling chimney

upward after locking. The chimney will not come

apart if properly locked. It is not necessary to add

screws to keep the chimney together (exception

- see Figure 9, page 10).

8

www.desatech.com

117541-01A

Image 8
Contents Save this Book Wood Burning Masonry Fireplaces with InsulationTable of Contents Safety InformationSpecifications Models VJM36 and JM36Models VJM42 and JM42 Specifications Models VJM50 and JM50Framing Selecting LocationMinimum Clearance to Combustibles Hearth Extension MantelsVenting Installation Assembly and InstallationOptional Outside AIR KIT Model AK4/AK4F Double Wall Chimney SystemUsing Elbow Offsets 30E-12DM Elbow SET onlyFirestop Spacers FS-10, 1100EFS-10DM for JM36 Penetrating the RoofFlashing Installation V6F-10DM or V12F-10DM Apply waterproof caulk aroundOptional GAS Line Installation Chase InstallationsFoot Rule Finishing the FireplaceBrick Installation Gas Line KnockoutInstalling Brick AO or AR Brick Installation for Model VJM36Brick Installation for Model VJM42 Brick Installation for Model VJM50See instruction on page 14 before installing brick AO See instruction on page 14 before install- ing brick AOBrick Matrix VJM36 Brick Matrix for Model VJM36Brick Matrix VJM42 Brick Matrix for Model VJM42Brick Matrix VJM50 Brick Matrix for Model VJM50To handle Installing Z-SHAPED Grate Retainer BracketGrouting Instructions Glass Door Installation Door Frame AssemblyInstalling Door Frame Installing Glass DoorsOutside AIR and Damper Handle Operation Operation Maintenance GuidelinesGlass Doors Technical Service Operating Damper HandleReplacement and Accessory Parts BI-FOLD Glass DoorNot a UPC
Related manuals
Manual 40 pages 9.16 Kb

(V)JM36, (V)JM50, (V)JM42 specifications

The Desa WCM-50J, WCM-36J, and WCM-42J are part of the (V)JM50 series and (V)JM36 series, renowned for their versatility and efficiency in various applications. These models are designed to meet the dynamic needs of modern users, providing reliable performance in multiple operating conditions.

One of the standout features of these models is their energy efficiency. Equipped with advanced thermal management systems, the WCM series optimizes power consumption while maintaining high output levels. This energy-efficient design not only reduces operational costs but also aligns with environmental sustainability practices, making them suitable for eco-conscious consumers.

In terms of technology, the WCM series integrates cutting-edge automation capabilities. These machines feature user-friendly interfaces that allow for easy programming and monitoring of operations. The intuitive controls enable users to adapt settings quickly to match specific requirements, enhancing productivity and minimizing downtime.

Additionally, the WCM-50J, WCM-36J, and WCM-42J models incorporate robust safety features to protect operators and equipment. Safety interlocks and emergency-stop mechanisms are standard, ensuring that the machines are safe to operate in diverse working environments. The durability of the build materials used in these models contributes to their long lifespan, reducing the need for frequent maintenance or replacements.

The compact design of the WCM series enhances their adaptability. Whether in a crowded workshop or a spacious industrial setting, these machines can be integrated seamlessly. Their lightweight construction does not compromise stability, allowing for easy repositioning as needed without sacrificing safety or performance.

Customer feedback highlights the exceptional reliability of the WCM series under various workloads. Users appreciate the consistent quality of output, which is essential for maintaining high standards in production and service delivery.

Overall, the Desa WCM-50J, WCM-36J, and WCM-42J, along with the (V)JM50 and (V)JM36 series, are ideal choices for those seeking advanced, efficient, and safe solutions in today’s competitive market. Their combination of innovative technology, user-friendly operation, and durability makes them a valuable investment for businesses aiming to enhance productivity and sustainability.