Desa (V)JM36, (V)JM50, (V)JM42 installation manual Table of Contents, Safety Information

Page 2

WARNING: Improper installation, adjustment, altera- tion, service or maintenance can cause injury, property damage or loss of life. Refer to this manual for assis- tance or additional information. Consult a qualified installer or local distributor.

TABLE OF CONTENTS

Safety Information

2

Brick Installation

13

Specifications

5

Glass Door Installation

20

Fireplace Installation

6

Operation and Maintenance Guidelines

21

Venting Installation

8

Technical Service

22

Optional Gas Line Installation

12

Replacement and Accessory Parts

23

SAFETY INFORMATION

IMPORTANT: Check local codes before installing this fireplace.

Before beginning the installation of the fireplace, read these instructions through completely.

This DESA fireplace and its components are safe when installed according to this installation manual. Unless you use DESA components, which have been designed and tested for the fireplace system, you may cause a fire hazard.

The DESA warranty will be voided by and DESA disclaims any responsibility for the following actions.

a.Modification of the fireplace, components, doors, air inlet system and damper control.

b.Use of any component part not manufac- tured or approved by DESA in combination with a DESA fireplace system.

Proper installation is the most important step in ensuring safe and continuous operation of the fireplace. Consult the local building codes as to the particular requirements concerned with the installation of all factory built fireplaces.

WARNING: Do not install a fireplace insert in this box unless the manufacturer's instructions with the insert specifically state this fireplace has been tested for use with this insert.

FOR YOUR SAFETY

Do not store or use gasoline or any other flammable vapors or liquids in the vicinity of this or any other appliance.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

Do not place clothing or other flammable materials on or near the appliance.

Never leave children unat- tended when a fire is burning in the fireplace.

WARNING: Use solid wood or processed solid fuel firelogs only. When processed wood fuel fire logs are used, do not poke or stir the logs while they are burn- ing. Use only fire logs that have beenevaluatedfortheapplication in fireplace and refer to fire log warnings and caution markings on packaging prior to use.

Thisfireplaceisnotintendedtobe used as a substitute for a furnace to heat an entire home. Use for supplemental heat only.

2

www.desatech.com

117541-01A

Image 2
Contents Save this Book Wood Burning Masonry Fireplaces with InsulationTable of Contents Safety InformationSpecifications Models VJM36 and JM36Models VJM42 and JM42 Specifications Models VJM50 and JM50Framing Selecting LocationMinimum Clearance to Combustibles Hearth Extension MantelsOptional Outside AIR KIT Model AK4/AK4F Venting InstallationAssembly and Installation Double Wall Chimney SystemUsing Elbow Offsets 30E-12DM Elbow SET onlyFirestop Spacers FS-10, 1100EFS-10DM for JM36 Penetrating the RoofFlashing Installation V6F-10DM or V12F-10DM Apply waterproof caulk aroundFoot Rule Optional GAS Line InstallationChase Installations Finishing the FireplaceBrick Installation Gas Line KnockoutInstalling Brick AO or AR Brick Installation for Model VJM36See instruction on page 14 before installing brick AO Brick Installation for Model VJM42Brick Installation for Model VJM50 See instruction on page 14 before install- ing brick AOBrick Matrix VJM36 Brick Matrix for Model VJM36Brick Matrix VJM42 Brick Matrix for Model VJM42Brick Matrix VJM50 Brick Matrix for Model VJM50To handle Installing Z-SHAPED Grate Retainer BracketGrouting Instructions Installing Door Frame Glass Door InstallationDoor Frame Assembly Installing Glass DoorsOutside AIR and Damper Handle Operation Operation Maintenance GuidelinesGlass Doors Technical Service Operating Damper HandleReplacement and Accessory Parts BI-FOLD Glass DoorNot a UPC
Related manuals
Manual 40 pages 9.16 Kb

(V)JM36, (V)JM50, (V)JM42 specifications

The Desa WCM-50J, WCM-36J, and WCM-42J are part of the (V)JM50 series and (V)JM36 series, renowned for their versatility and efficiency in various applications. These models are designed to meet the dynamic needs of modern users, providing reliable performance in multiple operating conditions.

One of the standout features of these models is their energy efficiency. Equipped with advanced thermal management systems, the WCM series optimizes power consumption while maintaining high output levels. This energy-efficient design not only reduces operational costs but also aligns with environmental sustainability practices, making them suitable for eco-conscious consumers.

In terms of technology, the WCM series integrates cutting-edge automation capabilities. These machines feature user-friendly interfaces that allow for easy programming and monitoring of operations. The intuitive controls enable users to adapt settings quickly to match specific requirements, enhancing productivity and minimizing downtime.

Additionally, the WCM-50J, WCM-36J, and WCM-42J models incorporate robust safety features to protect operators and equipment. Safety interlocks and emergency-stop mechanisms are standard, ensuring that the machines are safe to operate in diverse working environments. The durability of the build materials used in these models contributes to their long lifespan, reducing the need for frequent maintenance or replacements.

The compact design of the WCM series enhances their adaptability. Whether in a crowded workshop or a spacious industrial setting, these machines can be integrated seamlessly. Their lightweight construction does not compromise stability, allowing for easy repositioning as needed without sacrificing safety or performance.

Customer feedback highlights the exceptional reliability of the WCM series under various workloads. Users appreciate the consistent quality of output, which is essential for maintaining high standards in production and service delivery.

Overall, the Desa WCM-50J, WCM-36J, and WCM-42J, along with the (V)JM50 and (V)JM36 series, are ideal choices for those seeking advanced, efficient, and safe solutions in today’s competitive market. Their combination of innovative technology, user-friendly operation, and durability makes them a valuable investment for businesses aiming to enhance productivity and sustainability.