Desa (V)JM50, (V)JM42, (V)JM36 installation manual Operation Maintenance Guidelines, Glass Doors

Page 21

OPERATION AND

MAINTENANCE

GUIDELINES

GLASS DOORS

Glass doors are optional with the fireplace. When the fireplace is in operation, doors must be fully opened or fully closed position only or a fire hazard may be created (see Figure 28).

A fireplace equipped with glass doors operates mush differently than a fireplace with an open front. A fireplace with glass doors has a limited amount of air for combustion.

Excessive heat within the fireplace can result if too large a fire is built or if the combustion air gate is not completely open. The following tips should be followed to assure that both the fireplace and the glass door retain their beauty and function properly. Both the flue damper and the glass doors must be fully opened before starting the fire. This will provide sufficient combustion air and maintain safe temperatures in the firebox.

IMPORTANT: The glass must be allowed to warm slowly and evenly. The tempered glass will withstand a gradual temperature rise to 550° F, which is more than a normal fire will generate. Such materials as pitch/wax laden logs, very dry mill end lumber and large amounts of paper or cardboard boxes can create an excessively hot fire and should not be burned in this fireplace. Always keep the fire well back from the doors and never allow flames to contact the glass.

Doors Fully Closed

Fireplace Front

Doors

Fully Opened

Fireplace Front

Figure 28 - Bi-Fold Glass Doors

WARNING: Fireplaces equipped with glass doors should be operated only with doors fully opened or doors fully closed. Doors, if left partly open, may draw gas and flame out of the fireplace opening creating risks of both fire and smoke.

Cleaning the Glass

Clean the glass with any commercial glass cleaner or soap and water. Do not use any abrasive mate- rial to clean the glass. Do not clean the glass with any cool water is the glass is still hot from the fire and smoke.

A gas line or gas log lighter may be installed for the purpose of installing a vented or vent-free deco- rative gas appliance incorporating an automatic shutoff device and complying with the Standard for Decorative Gas Appliances for Installation in Vented Fireplaces, ANSI Z21.60 or American Gas Association draft requirements for Gas Fired Log Lighters for Wood Burning Fireplaces, Draft NO. 4 dated August, 1993.

If you wish to install an unvented (vent-free) gas log set, only unvented gas log sets which have been found to comply with the standard for unvented room heaters, ANSI Z21.11.2 are to be installed in this fireplace.

OUTSIDE AIR AND DAMPER HANDLE OPERATION

The damper handle, which opens and closes the damper blade, is located in the upper front face of the fireplace. Pushing the handle forward and up of the keyway slot will free the damper blade to automatically open. Pushing the handle forward and down will lock the damper blade closed (see Figure 29, page 22).

The outside air kit lever is located at the left and right hand sides of the fireplace (see Figure 30, page 22) Lifting the lever up will free the outside air door to open. Pulling the lever down will lock the door.

117541-01A

www.desatech.com

21

Image 21
Contents Wood Burning Masonry Fireplaces with Insulation Save this BookSafety Information Table of ContentsModels VJM36 and JM36 SpecificationsModels VJM42 and JM42 Models VJM50 and JM50 SpecificationsSelecting Location Minimum Clearance to CombustiblesFraming Mantels Hearth ExtensionAssembly and Installation Venting InstallationOptional Outside AIR KIT Model AK4/AK4F Double Wall Chimney SystemElbow SET only Using Elbow Offsets 30E-12DMPenetrating the Roof Firestop Spacers FS-10, 1100EFS-10DM for JM36Apply waterproof caulk around Flashing Installation V6F-10DM or V12F-10DMChase Installations Optional GAS Line InstallationFoot Rule Finishing the FireplaceGas Line Knockout Brick InstallationBrick Installation for Model VJM36 Installing Brick AO or ARBrick Installation for Model VJM50 Brick Installation for Model VJM42See instruction on page 14 before installing brick AO See instruction on page 14 before install- ing brick AOBrick Matrix for Model VJM36 Brick Matrix VJM36Brick Matrix for Model VJM42 Brick Matrix VJM42Brick Matrix for Model VJM50 Brick Matrix VJM50Installing Z-SHAPED Grate Retainer Bracket Grouting InstructionsTo handle Door Frame Assembly Glass Door InstallationInstalling Door Frame Installing Glass DoorsOperation Maintenance Guidelines Glass DoorsOutside AIR and Damper Handle Operation Operating Damper Handle Technical ServiceBI-FOLD Glass Door Replacement and Accessory PartsNot a UPC
Related manuals
Manual 40 pages 9.16 Kb

(V)JM36, (V)JM50, (V)JM42 specifications

The Desa WCM-50J, WCM-36J, and WCM-42J are part of the (V)JM50 series and (V)JM36 series, renowned for their versatility and efficiency in various applications. These models are designed to meet the dynamic needs of modern users, providing reliable performance in multiple operating conditions.

One of the standout features of these models is their energy efficiency. Equipped with advanced thermal management systems, the WCM series optimizes power consumption while maintaining high output levels. This energy-efficient design not only reduces operational costs but also aligns with environmental sustainability practices, making them suitable for eco-conscious consumers.

In terms of technology, the WCM series integrates cutting-edge automation capabilities. These machines feature user-friendly interfaces that allow for easy programming and monitoring of operations. The intuitive controls enable users to adapt settings quickly to match specific requirements, enhancing productivity and minimizing downtime.

Additionally, the WCM-50J, WCM-36J, and WCM-42J models incorporate robust safety features to protect operators and equipment. Safety interlocks and emergency-stop mechanisms are standard, ensuring that the machines are safe to operate in diverse working environments. The durability of the build materials used in these models contributes to their long lifespan, reducing the need for frequent maintenance or replacements.

The compact design of the WCM series enhances their adaptability. Whether in a crowded workshop or a spacious industrial setting, these machines can be integrated seamlessly. Their lightweight construction does not compromise stability, allowing for easy repositioning as needed without sacrificing safety or performance.

Customer feedback highlights the exceptional reliability of the WCM series under various workloads. Users appreciate the consistent quality of output, which is essential for maintaining high standards in production and service delivery.

Overall, the Desa WCM-50J, WCM-36J, and WCM-42J, along with the (V)JM50 and (V)JM36 series, are ideal choices for those seeking advanced, efficient, and safe solutions in today’s competitive market. Their combination of innovative technology, user-friendly operation, and durability makes them a valuable investment for businesses aiming to enhance productivity and sustainability.