Desa (v)V42EP SERIES installation manual Model BKT Installation, Blower Model BK

Page 15

Fireplace Installation

Continued

3.Place the blower against the lower rear wall of the firebox outer wrapper with the exhaust port directed upward. The blower will fit inside the back opening and be held in position against the back wall by the magnets (see Figure 25).

4.Be certain that all wire terminals are securely attached to ter- minals on blower motor and that the screw retaining the green ground wire is tight.

5.Mount speed control box to switch bracket by placing the plastic control shaft forward through the opening in the switch bracket (see Figure 26).

6.While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise until it is tight against front panel. Place control knob provided on shaft.

7.Turn on power to duplex outlet if previously turned off per the warning in column 2, page 14.

8.Plug in blower power cord.

a.If your firebox is installed as a freestanding unit with an accessory mantel, determine whether the power cord will exit the left side or the right side of the firebox. Route power cord through exit hole and plug the power cord into a wall receptacle near the firebox.

b.If your firebox installation is recessed and/or pre-wired, plug the power cord into the duplex outlet provided. Refer to your firebox owner’s manual for instructions on wiring the duplex outlet.

CAUTION: Never touch the blower wheel while in operation.

9.Check to make sure that the power cord is completely clear of the blower wheel and that there are no other foreign objects in blower wheel. Turn blower on and check for operation. Turn blower off by turning knob fully counterclockwise before continuing.

10.Peel off the backing paper and stick the supplied wiring diagram decal on the firebox bottom approximately 12" in front of the blower (see Figure 27).

 

 

Blower

 

 

Location

 

Lower Firebox

 

 

Cavity

 

Side View

Spade

 

 

Magnetic

 

Terminals

 

 

Strips

Exhaust

Port

Green

Ground Wire

Screw

Figure 25 - Blower Model BK

Switch

Speed Control

Bracket

 

 

 

Blower

 

Plug-In

 

 

Duplex Outlet (Located

Locknut

 

underneath firebox

Control Shaft

floor against lower right

Control Knob

outside wall)

 

Figure 26 - Attaching Speed Control to Firebox

Wiring Diagram Decal

12" in Front of Blower

Figure 27 - Location of Wiring Diagram Decal (Model May

Vary From Illustration)

Model BKT Installation

Note: When installing the BKT thermostatically-controlled blower, you must first secure the thermal switch bracket to the blower if it has not already been factory installed.

1. Place the green ground wire with ring terminal between the bottom hole on the thermal switch bracket and the top ear hole on the blower assembly. Insert the Phillips screw into all three pieces and tighten securely (see Figure 28, page 16).

2. Connect wire harness and power cord terminals. Connect the blue jumper wire to the blower motor terminal and the right side terminal of the thermal switch. Connect the black wire to the left side of the thermal switch and the white wire to the other remaining blower motor terminal.

Note: The power cord outer insulation sleeve may have to be stripped slightly to allow enough wire length to reach and make all connections. DO NOT trim excessive length away. Just enable enough to make all connections securely.

108862-01E

www.desatech.com

15

Image 15
Contents What to do if YOU Smell GAS For Your SafetySafety Information Table of ContentsProduct Features Product IdentificationLocal Codes Pre-Installation Preparation Location and space requirementsClearances Framing and finishing Framing Clearances for Installation Against an Exterior WallTermination CAP AIR Supply Inlet GAS Meter Location of Termination CapHorizontal Termination Installation Venting Installation InstructionsInstallation Precautions Installation PlanningVent Pipe Connections Slide the wall firestop over the vent pipe before connecting Square Termination Vertical Horizontal Termination ConfigurationsVenting with Two 90 Elbows Snorkel Termination InstallationFlat Ceiling Installation Installation for vertical terminationVertical Venting Vertical Termination ConfigurationsInstalling optional blower accessories Fireplace InstallationHigh Altitude Installation Parts lists for venting kits and componentsBlower Model BK Model BKT InstallationInstalling Gas Piping to Fireplace Location Blower Wiring DiagramInstallation Items Needed Installation Items Needed Connecting Fireplace to GAS SupplyTest Pressures In Excess Of 1/2 Psig 3.5 kPa Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Gas Connections Checking GAS ConnectionsRemoving Louver Panels Cleaning Glass DoorUnplug fireplace. Let cool before installing brick liner Removing/Replacing Glass DoorInstalling Rear Brick Panel Installing logs, lava rock and glowing embersOptional Remote control Installation model WRC Wall Switch InstallationLine Wiring DiagramTo Turn OFF GAS To Appliance For your safety read Before lightingOperating Fireplace Lighting InstructionsBurner Flame Pattern Operating optional Blower accessoryPilot assembly Inspecting BurnersLogs Cleaning MaintenanceGlass Door Pilot and burnersTo clean pilot. This can damage pilot unit TroubleshootingTop above Gas leak. See Warning statement atSpecifications Replacement PartsService Hints Technical ServiceAccessories Models VV36EN, VV36ENS, VV36ENH, VV36EP, VV36EPS and VV36EPH Illustrated Parts BreakdownParts List Illustrated parts breakdown Parts List Models VV42EN, VV42ENS, VV42ENH, VV42EP, VV42EPS and VV42EPH 25487 27253 Lava Rock/Bag Assembly Vent Label 325 12 11 Parts List Keep this Warrant Warranty Information