Location of Termination Cap

D

E V

B L

 

C

 

 

Fixed

V

 

Closed

 

 

F

Openable

 

V

 

 

B

 

B

Openable

B

Fixed

Closed

H

V

B

I

V J XG

AM

NN

 

G

 

V

 

G

V K X

V

A

V TERMINATION CAP

X AIR SUPPLY INLET

G

GAS METER

RESTRICTED AREA (TERMINATION PROHIBITED)

A= clearance above grade, veranda, porch, deck, or balcony [*12" (30.5 cm) minimum]

B= clearance to window or door that may be opened

[12" (30.5 cm) minimum]

C = clearance to permanently closed window [minimum 12" (30.5 cm) recommended to prevent condensation on window]

D = vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 24" (61cm) from the center-line of the terminal [18" (45.7 cm) minimum]

E= clearance to unventilated soffit [12" (30.5 cm) minimum]

F= clearance to outside corner (see below)

G= clearance to inside corner (see below)

H= *not to be installed above a meter/regulator assembly within 36" (91.4 cm) horizontally from the center-line of the regulator

I= clearance to service regulator vent outlet [*72" (182.9 cm) minimum]

J= clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other fireplace [*12" (30.5 cm) minimum]

K= clearance to a mechanical air supply inlet [*72" (182.9 cm) minimum]

L= † clearance above paved side-walk or a paved driveway located on public property [*84" (213.3 cm) minimum]

M= clearance under veranda, porch, deck [*12" (30.5 cm) minimum ‡]

N= clearance above a roof shall extend a minimum of 24" (61 cm) above the highest point when it passes through the roof surface and any other obstruction within a horizontal distance of 18" (45.7 cm)

vent shall not terminate directly above a side-walk or paved driveway which is located between two single family dwellings and serves both dwellings*

only permitted if veranda, porch, deck or balconey is fully open on a minimum of 2 sides beneath the floor* * as specified in CAN/CSA B149 (.1 or .2) Installation Codes (1991) for Canada and U.S.A.

Note: Local codes or regulations may require different clearances

Termination Clearances for Buildings with Combustible and Noncombustible Exteriors

Inside Corner

Outside Corner

Recessed Location

A

A = 6" (15.2 cm)

V

V

B

 

B = 6" (15.2 cm)

 

 

D

C

C

E

V

Balcony with No Side Wall

G

V

G = 12" (30.5 cm) minimum clearance

Balcony with Perpendicular Side Wall

H

V

J

Combustible &

Noncombustible

H = 24" (61 cm)

J = 20" (50.8 cm)

C = Maximum depth of 48" (121.9 cm) for recessed location

D = Minimum width for back wall of recessed location - Combustible - 38" (96.5 cm) Noncombustible - 24" (61cm)

E = Clearance from corner in recessed location- Combustible - 6" (15.2 cm) Noncombustible - 2" (5.1 cm)

Figure 7 - Minimum Clearances for Termination Cap

www.desatech.com

108862-01E

Image 6
Contents For Your Safety What to do if YOU Smell GASTable of Contents Safety InformationProduct Features Product IdentificationLocal Codes Pre-Installation Preparation Location and space requirementsClearances Framing Clearances for Installation Against an Exterior Wall Framing and finishingLocation of Termination Cap Termination CAP AIR Supply Inlet GAS MeterInstallation Planning Venting Installation InstructionsInstallation Precautions Horizontal Termination InstallationVent Pipe Connections Slide the wall firestop over the vent pipe before connecting Horizontal Termination Configurations Square Termination VerticalSnorkel Termination Installation Venting with Two 90 ElbowsInstallation for vertical termination Flat Ceiling InstallationVertical Termination Configurations Vertical VentingParts lists for venting kits and components Fireplace InstallationHigh Altitude Installation Installing optional blower accessoriesModel BKT Installation Blower Model BKInstalling Gas Piping to Fireplace Location Blower Wiring DiagramInstallation Items Needed Connecting Fireplace to GAS Supply Installation Items NeededChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Gas Connections Test Pressures In Excess Of 1/2 Psig 3.5 kPaRemoving/Replacing Glass Door Cleaning Glass DoorUnplug fireplace. Let cool before installing brick liner Removing Louver PanelsInstalling logs, lava rock and glowing embers Installing Rear Brick PanelWall Switch Installation Optional Remote control Installation model WRCWiring Diagram LineLighting Instructions For your safety read Before lightingOperating Fireplace To Turn OFF GAS To ApplianceInspecting Burners Operating optional Blower accessoryPilot assembly Burner Flame PatternPilot and burners Cleaning MaintenanceGlass Door LogsTroubleshooting To clean pilot. This can damage pilot unitGas leak. See Warning statement at Top aboveTechnical Service Replacement PartsService Hints SpecificationsAccessories Illustrated Parts Breakdown Models VV36EN, VV36ENS, VV36ENH, VV36EP, VV36EPS and VV36EPHParts List Illustrated parts breakdown Parts List Models VV42EN, VV42ENS, VV42ENH, VV42EP, VV42EPS and VV42EPH 25487 27253 Lava Rock/Bag Assembly Vent Label 325 12 11 Parts List Warranty Information Keep this Warrant