Desa (v)V42EP SERIES installation manual Parts List

Page 31

Parts List

MODELS (V)V36EN, (V)V36ENS, (V)V36ENH, (V)V36EP, (V)V36EPS and (V)V36EPH

This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 28 of this manual.

KEY

(V)V36EN

(V)V36ENS

(V)V36ENH

 

NO.

(V)V36EP

(V)V36EPS

(V)V36EPH

DESCRIPTION

1

**

**

**

Firebox Assembly

2

**

**

**

Face Weldment

3

108010-01

108010-01

108010-01

Door Assembly (V Models Only)

 

108010-02

108010-02

108010-02

Door Assembly (VV Models Only)

4 108011-01 108011-01 108011-01 Top Panel Louver Assembly

5 108011-02 108011-02 108011-02 Bottom Panel Louver Assembly

6

**

**

**

Fireplace Top

 

7

**

**

**

Fireplace Top Insulation

8

**

**

**

Fireplace Surround

9

109082-01 109082-01

109082-01

Heat Shield

 

10

___

See Below

See Below

Top Refractory

Brick Panel

___

11

See Below

See Below

Left Refractory

Brick Panel

___

12

See Below

See Below

Rear Refractory Brick Panel

___

13

See Below

See Below

Right Refractory Brick Panel

 

14 108076-01 108076-01 108076-01 Burner Base Gasket

15 108719-01 108719-01 108719-01 Screen Rod

16

12105

12105

 

12105

Screen

17

11418

11418

 

11418

Push-On Nut

18

14123

14123

 

14123

Strain Relief

19

21171

21171

 

21171

Gas Knock-Out Cover

20

24353

24353

 

24353

Handy Box Assembly

21

24460

24460

 

24460

Gas Conduit Assembly

22

108760-03

108760-03

108760-03

Burner Assembly (Natural Gas)

 

108760-04

108760-04

108760-04

Burner Assembly (Propane/LP Gas)

23

108032-01

108032-01

108032-01

Log Set

23-1 109128-01

109128-01

109128-01 Front Log (Log 1)

23-2 109129-01

109129-01

109129-01 Rear Log (Log 2)

23-3 109130-01

109130-01

109130-01 Crossover Log (Log 3)

23-4 109131-01

109131-01

109131-01 Top Log (Log 4)

23-5 109132-01

109132-01

109132-01 Left Log (Log 5)

23-6

109133-01

109133-01

109133-01 Base Log (Log 6)

 

 

 

PARTS AVAILABLE - NOT SHOWN

 

 

 

QTY.

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

2

2

1

2

1

1

1

1

1

1

1

1

1

1

1

25487

25487

25487

27253

27253

27253

55240

55240

55240

** Part not available for field replacement.

Lava Rock/Bag Assembly

Notice Label

Vent Label

1

1

1

 

 

REFRACTORY BRICK PANELS

 

 

V36ENS, V36EPS VV36ENS, VV36EPS

V36ENH, V36EPH

VV36ENH, VV36EPH

DESCRIPTION

QTY

108081-02

108081-01

108175-02

108175-01

Top Refractory Brick Panel

1

108083-02

108083-01

108177-02

108177-01

Left Refractory Brick Panel

1

108080-02

108080-01

108174-02

108174-01

Rear Refractory Brick Panel

1

108082-02

108082-01

108176-02

108176-01

Right Refractory Brick Panel

1

108862-01E

www.desatech.com

31

Image 31
Contents What to do if YOU Smell GAS For Your SafetySafety Information Table of ContentsProduct Identification Product FeaturesLocal Codes Location and space requirements Pre-Installation PreparationClearances Framing and finishing Framing Clearances for Installation Against an Exterior WallTermination CAP AIR Supply Inlet GAS Meter Location of Termination CapHorizontal Termination Installation Venting Installation InstructionsInstallation Precautions Installation PlanningVent Pipe Connections Slide the wall firestop over the vent pipe before connecting Square Termination Vertical Horizontal Termination ConfigurationsVenting with Two 90 Elbows Snorkel Termination InstallationFlat Ceiling Installation Installation for vertical terminationVertical Venting Vertical Termination ConfigurationsInstalling optional blower accessories Fireplace InstallationHigh Altitude Installation Parts lists for venting kits and componentsBlower Model BK Model BKT InstallationBlower Wiring Diagram Installing Gas Piping to Fireplace LocationInstallation Items Needed Installation Items Needed Connecting Fireplace to GAS SupplyTest Pressures In Excess Of 1/2 Psig 3.5 kPa Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Gas Connections Checking GAS ConnectionsRemoving Louver Panels Cleaning Glass DoorUnplug fireplace. Let cool before installing brick liner Removing/Replacing Glass DoorInstalling Rear Brick Panel Installing logs, lava rock and glowing embersOptional Remote control Installation model WRC Wall Switch InstallationLine Wiring DiagramTo Turn OFF GAS To Appliance For your safety read Before lightingOperating Fireplace Lighting InstructionsBurner Flame Pattern Operating optional Blower accessoryPilot assembly Inspecting BurnersLogs Cleaning MaintenanceGlass Door Pilot and burnersTo clean pilot. This can damage pilot unit TroubleshootingTop above Gas leak. See Warning statement atSpecifications Replacement PartsService Hints Technical ServiceAccessories Models VV36EN, VV36ENS, VV36ENH, VV36EP, VV36EPS and VV36EPH Illustrated Parts BreakdownParts List Illustrated parts breakdown Parts List Models VV42EN, VV42ENS, VV42ENH, VV42EP, VV42EPS and VV42EPH 25487 27253 Lava Rock/Bag Assembly Vent Label 325 12 11 Parts List Keep this Warrant Warranty Information