INSTALLATION
Continued
Minimum Clearances For Side Combustible Material, Side Wall, and Ceiling
A.Clearances from the side of the fireplace cabi- net to any combustible material and wall should follow diagram in Figure 6.
Example: The face of a mantel, bookshelf, etc. is made of combustible material and pro- trudes 3 1/2" from the wall. This combustible material must be 4" from the side of the fire- place opening (see Figure 6).
B.Clearances from the top of the fireplace opening to the ceiling should not be less than 36 inches.
C.For mantel clearances, see Figure 10 on page 12.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS
Top | Left and | Bottom |
| Right Sides | and Rear |
36" | 6" | 0" |
| Example |
|
|
| * |
*Minimum 16 inches from Side Wall
Figure 6 - Minimum Clearance for
Combustible to Wall
BUILT-IN FIREPLACE
INSTALLATION
11.Follow the instructions below to install the fire- place in this manner.
| Actual | Framing |
Height | 26" | 26 7/8" |
Front Width | 26 3/4" | 26 7/8" |
Depth | 9 1/2" | 10 1/2" |
Bottom | 3/4" | 3/4" |
1.Frame in rough opening. Use dimensions shown in Figure 7 for the rough opening. If installing in a corner, use dimensions shown in Figure 8 for the rough opening. The height is 26 7/8" which is the same as the wall opening above.
2.If installing GA3450T blower accessory, do so at this time. Follow instructions included with blower accessory.
Note: If not installing blower accessory, you may wish to run electrical wiring to your fire- place for future blower installation (see Ac- cessories, page 40). Use only approved three- wire electrical wiring.
WARNING: If
Install fireplace electrical outlet and connect wiring to outlet be- fore connecting to electrical source. The fireplace electrical outlet is included with the GA3450T blower accessory.
Only use the fireplace electrical outlet supplied with the GA3450T blower accessory.
Note: A qualified installer should make all elec- trical connections.
101/2"
267/8"
3/4" Off
The Floor
267/8" Minimum
Figure 7 - Rough Opening for Installing
in Wall
365/8"
257/8"
267/8" 513/4"
Figure 8 - Rough Opening for Installing
in Corner
www.desatech.com | 11 |