Desa EFS10RNA, CGCF10NR Installing Optional Blower Accessory GA3450T, Removing Upper Louver

Page 14

INSTALLATION

Continued

Assembling Trim (Trim shipped with mantel)

1.Remove packaging from three remaining pieces of trim.

2.Locate two adjusting plates with set screws, and two shims in the hardware packet.

3.Align shim under adjusting plate as shown in Figure 13.

4.Slide one end of adjusting plate/shim in slot on mitered edge of top trim (see Figure 13).

5.Slide other end of adjusting plate/shim in slot on mitered edge of side trim (see Figure 13).

6.While firmly holding edges of trim together, tighten both set screws on the adjusting plate with slotted screwdriver.

7.Repeat steps 1 through 6 for other corner.

8.Set assembly aside for later installation.

Top Trim

Set

Adjusting Plate

 

Screws

 

Slot

Mitered Edge

Shim

Side Trim

Figure 13 - Assembling Trim

INSTALLING OPTIONAL BLOWER ACCESSORY GA3450T

Removing Upper Louver

To install the blower accessory, you must first re- move the upper louver.

1.Lift screen off fireplace and remove log set if installed.

2.Remove 4 screws from upper louver (see Fig- ure 14). Save these screws.

3.Pull upper louver straight out from the cabi- net. Be careful not to scratch the paint. Set louver and screws aside.

4.Open lower louver door by swinging door down (see Figure 15, page 15).

Blower

Bracket

Mounting

Holes

Upper Louver

Figure 14 - Removing Upper Louver

Installing Blower Accessory

Note: If you are using a mantel with your fireplace, use the following instructions. If your fireplace is built-in, see For Built-In Installation, page 16.

CAUTION: Label all wires prior to disconnection when ser- vicing controls. Wiring errors can cause improper and dan- gerous operation.

CAUTION: Verify proper op- eration after servicing.

1.Locate fan switch cover. Remover bottom screw to remove back portion of the cover.

2.Install snap bushings found in hardware kit into both holes in rear of fan switch cover.

3.Make sure the wire harness is firmly con- nected to the terminals on the blower bracket assembly.

4.Note the wire locations on back of AUTO/ OFF/ON switch. The terminals on back of switch are numbered 1, 2, and 3. Carefully remove red wire from terminal 3 and blue wire from terminal 1. Black wire can remain on middle terminal 2 (see Figure 15, page 15).

5.Carefully disconnect green and white wires at their insulated connectors (see Figure 16, page 15).

14

www.desatech.com

112462-01C

Image 14
Contents What to do if YOU Smell GAS Table of Contents Safety Information Local Codes Product Identification Product FeaturesOptional Remote Control Accessories UnpackingShoulder Screw Screen AssemblyAssembling Fireplace Hood Tabs Louver Baffle Sheet Metal Screws Firebox TopConfined and Unconfined Space AIR for Combustion VentilationProviding Adequate Ventilation Determining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Fireplace LocationVentilation AIR Ventilation Air From Inside BuildingInstallation Ventilation Air from Inside BuildingFireplace Clearances Installation ItemsCheck GAS Type Example BUILT-IN Fireplace InstallationMinimum Clearance to Combustible Materials Flanges Mantel Clearances for Built-In InstallationIf you have not assembled firebox, follow in- structions on Optional Mantel Installation Assembling Trim Trim shipped with mantel Installing Optional Blower Accessory GA3450TInstalling Blower Accessory Removing Upper LouverPower Cord Snap Bushing Wire HarnessScrew Wiring Routing Hole Baffle For Built-In Installation Extension CordIncluded Connecting to GAS SupplyAttaching Wood Base to Solid Floor DoorPropane/LP Checking GAS Connections Connecting Fireplace to GAS SupplyInstallation Items Needed Test Pressures In Excess Of 1/2 Psig 3.5 kPaClosed Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaEquipment Shutoff Valve Equipment Gas Regulator orInstalling 9-Volt Battery in Hand-Held Remote Control Unit Optional Wireless HAND-HELD Remote Control AccessoriesInstalling Receiver Terminal W Terminal R R Control Valve Jumper Wire One terminal of 25 ft. wireFeed wires through rectangular slots Shoulder Screw Log Screen Installing LOG SET and ScreenOperating Fireplace Thermocouple Ignitor Electrode Pilot Burner Lighting InstructionsElectronic Ignitor Button Control Knob Ignitor ThermocoupleTo Turn OFF GAS To Appliance Manual Lighting ProcedureREMOTE-READY Models For Your Safety Read Before Lighting Thermostat Control OperationPilot Burner Ignitor Electrode Control Knob Electronic IgnitorPilot Ignitor Burner Electrode Optional HAND-HELD Remote Operation ON/OFF Series Model GhrcbGWMT1 Wall Mounted Thermostat Optional GWMS2 Wall Mounted Switch OptionalThermostat Series Model Ghrctb Burner Flame Pattern Inspecting BurnersPilot Flame Pattern Pilot Burner ThermocoupleLOG SET Cleaning MaintenanceBurner Injector Holder and Pilot AIR Inlet Hole CabinetObserved Problem Possible Cause Remedy TroubleshootiingTroubleshooting Tial operation Bris. If found, clean burnerResidues from manufactur Hours of operationGas leak. See Warning Replacement Parts SpecificationsWiring Diagram Service HintsInstall Battery According To This Illustration Illustrated Parts BreakdownParts List THERMOSTAT-CONTROLLED Models935 Parts Available not Shown Accessories Receiver and HAND-HELD Remote Control KIT Ghrcb WALL-MOUNT ON/OFF Switch GWMS2Receiver and HAND-HELD Thermostat Remote Control KIT Ghrctb Corner Mantel with Full Hearth Base112462-01C 112462-01C Limited Warranty VENT-FREE Compact Classic Hearth Fireplace Warranty InformationKeep this Warranty