PARTS LIST

THERMOSTAT-CONTROLLED MODELS

This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 35 of this manual.

 

PART NUMBERS

 

 

KEY

VMH10TPC

VMH10TNC

 

 

NO.

EFS10TPA

EFS10TNA

DESCRIPTION

QTY.

 

 

 

 

 

1

102633-02

102633-02

Outer Casing Top

1

2

102624-02

102624-02

Outer Casing

1

3

099230-02

099230-02

Shoulder Screw

14

4

098304-01

098304-01

Screw, #10-16 x 3/8"

4

5

112066-01

112066-01

Burner

1

6

103209-05

103209-05

Extruded Louver

2

7

102635-02

102635-02

Left and Right Side Front

2

8

M11084-26

M11084-26

Hex Head Screw, #10-16 x 3/8"

39

9

111725-03

111725-03

Pilot Bracket

1

10

104281-01CK

104281-01CK

Firebox Hood

1

11

102638-01

102638-01

Firebox Top

1

12

104286-01

104285-01

ODS/Pilot Assembly

1

13

**

**

Firebox Wrapper

1

14

099211-01

099211-01

Control Bracket Screw

2

15

112070-01

112070-01

Inlet Tube

1

16

112071-01

112071-01

Burner Tube

1

17

112067-01

112067-01

Electronic Ignitor Bracket

1

18

M11084-38

M11084-38

Screw #8-18 x 3/8

3

19

104335-01CK

104335-01CK

Outer Shell Base

1

20

**

**

Firebox Floor

1

21

099415-04

099415-10

Gas Regulator

1

22

099123-01

099123-01

Thermobulb Clip

2

23

111435-01

111435-01

Electronic Ignitor

1

24

099387-13

099387-13

Pilot Tube

1

25

098271-10

098271-10

Ignitor Cable

1

26

098249-01

098249-01

Nut, M5

2

27

101004-13

101004-12

Injector

1

28

098522-27

098522-27

Gas Valve

1

29

102639-01

102639-01

Baffle

1

30

101628-03

101628-03

Flexible Connector

1

31

102869-01

102869-01

Control Bracket

1

32

100587-01

100587-01

Screw, 6-20 x .38

4

33

103295-06CK

103295-06CK

Screen Assembly

1

34

112750-01

112750-01

Log Set

1

35

104313-01

104313-01

Hinge Pin (Right)

1

36

104313-02

104313-02

Hinge Pin (Left)

1

37

M10908-2

M10908-2

Hinge Screws

4

38

112068-01

112068-01

Fan Switch Box

1

39

112069-01

112069-01

Fan Switch Cover

1

40

097809-03

097809-03

3/8" NPT x 3/8" Flare Brass Fitting

1

41

101629-02

101629-02

Bushing

1

 

 

 

 

 

 

 

PARTS AVAILABLE — NOT SHOWN

 

 

101054-01

101054-01

Lighting Instructions Plate

1

 

100563-01

100563-01

Warning Plate

1

 

103470-01

103470-01

Hardware Package

1

** Part not available for field replacement.

112462-01C

www.desatech.com

37

Image 37
Contents What to do if YOU Smell GAS Table of Contents Safety Information Local Codes Optional Remote Control Accessories Product FeaturesProduct Identification UnpackingAssembling Fireplace AssemblyShoulder Screw Screen Hood Tabs Louver Baffle Sheet Metal Screws Firebox TopProviding Adequate Ventilation AIR for Combustion VentilationConfined and Unconfined Space Ventilation AIR Determining FRESH-AIR Flow for Fireplace LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside BuildingVentilation Air from Inside Building InstallationCheck GAS Type Installation ItemsFireplace Clearances Minimum Clearance to Combustible Materials BUILT-IN Fireplace InstallationExample If you have not assembled firebox, follow in- structions on Mantel Clearances for Built-In InstallationFlanges Optional Mantel Installation Installing Blower Accessory Installing Optional Blower Accessory GA3450TAssembling Trim Trim shipped with mantel Removing Upper LouverScrew Wiring Routing Hole Baffle Wire HarnessPower Cord Snap Bushing Extension Cord For Built-In InstallationAttaching Wood Base to Solid Floor Connecting to GAS SupplyIncluded DoorPropane/LP Installation Items Needed Connecting Fireplace to GAS SupplyChecking GAS Connections Test Pressures In Excess Of 1/2 Psig 3.5 kPaEquipment Shutoff Valve Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaClosed Equipment Gas Regulator orInstalling Receiver Optional Wireless HAND-HELD Remote Control AccessoriesInstalling 9-Volt Battery in Hand-Held Remote Control Unit Feed wires through rectangular slots Control Valve Jumper Wire One terminal of 25 ft. wireTerminal W Terminal R R Operating Fireplace Installing LOG SET and ScreenShoulder Screw Log Screen Electronic Ignitor Button Control Knob Lighting InstructionsThermocouple Ignitor Electrode Pilot Burner Ignitor ThermocoupleREMOTE-READY Models For Your Safety Read Before Lighting Manual Lighting ProcedureTo Turn OFF GAS To Appliance Thermostat Control OperationPilot Ignitor Burner Electrode Control Knob Electronic IgnitorPilot Burner Ignitor Electrode ON/OFF Series Model Ghrcb Optional HAND-HELD Remote OperationThermostat Series Model Ghrctb GWMS2 Wall Mounted Switch OptionalGWMT1 Wall Mounted Thermostat Optional Pilot Flame Pattern Inspecting BurnersBurner Flame Pattern Pilot Burner ThermocoupleBurner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceLOG SET CabinetTroubleshootiing Observed Problem Possible Cause RemedyTroubleshooting Residues from manufactur Bris. If found, clean burnerTial operation Hours of operationGas leak. See Warning Wiring Diagram SpecificationsReplacement Parts Service HintsIllustrated Parts Breakdown Install Battery According To This IllustrationTHERMOSTAT-CONTROLLED Models Parts List935 Parts Available not Shown Accessories Receiver and HAND-HELD Thermostat Remote Control KIT Ghrctb WALL-MOUNT ON/OFF Switch GWMS2Receiver and HAND-HELD Remote Control KIT Ghrcb Corner Mantel with Full Hearth Base112462-01C 112462-01C Keep this Warranty Warranty InformationLimited Warranty VENT-FREE Compact Classic Hearth Fireplace