OBSERVED

POSSIBLE

 

PROBLEM

CAUSE

REMEDY

 

 

 

When control knob is pressed in and turned to the PILOT/IGN po- sition, there is spark at ODS/pilot but no igni- tion

1.Gas supply turned off or manual shutoff valve closed

2.Control knob not pressed in while being turned to PILOT/IGN position

3.Air in gas lines when installed

4.ODS/pilot is clogged

5.Gas regulator setting is not correct

1.Turn on gas supply or open manual shutoff valve

2.Press in control knob while turning to PILOT/ IGN position

3.Continue holding down control knob. Repeat ig- niting operation until air is removed

4.Clean ODS/pilot (see

C L E A N I N G A N D M A I N T E N A N C E , page 17) or replace ODS/pilot assembly

5.Replace gas regulator

18

ODS/pilot lights but

1.

Control knob not fully

1.

Press

in control

knob

flame goes out when

 

pressed in

 

 

 

fully

 

 

control knob is

2.

Control

knob

not

2.

After ODS/pilot lights,

released

 

pressed in long enough

 

keep

control

knob

 

 

 

 

 

 

 

pressed in 10 seconds

 

3.

Manual shutoff

valve

3.

Fully open manual shut-

 

 

not fully open

 

 

off valve

 

 

4.

Thermocouple connec-

4.

Hand tighten until snug,

 

 

tion

loose at control

 

then

tighten 1/4

turn

 

 

valve

 

 

 

 

more

 

 

 

5.

Pilot flame not touching

5.

A) Contact local natural

 

 

thermocouple,

which

 

gas company

 

 

 

allows thermocouple to

 

 

 

 

 

 

cool,

causing

pilot

 

B) Clean ODS/pilot (see

 

 

flame to go out. This

 

C L E A N I N G A N D

 

 

problem

could be

 

M A I N T E N A N C E ,

 

 

caused by one or both of

 

page

17) or replace

 

 

the following:

 

 

ODS/pilot assembly

 

 

A) Low gas pressure

 

 

 

 

 

 

B) Dirty

or partially

 

 

 

 

 

 

clogged ODS/pilot

 

 

 

 

 

6.

Thermocouple

dam-

6.

Replace thermocouple

 

 

aged

 

 

 

 

 

 

 

 

7.

Control valve damaged

7.

Replace control valve

Continued

Image 18
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information Safety Information Product Identification Local Codes Unpacking Product FeaturesSafety Device Piezo Ignition SystemInstallation Items Check GAS TypeLocating Heater Installing Heater to Wall Marking Screw LocationsInstalling Two Mounting Screws Folding AnchorPlacing Heater On Mounting Screws Connecting to GAS Supply Pressure Testing GAS Supply Piping System Checking GAS ConnectionsPressure Testing Heater GAS Connections Manual Shutoff ValveFor Your Safety Read Before Lighting Operating HeaterLighting Instructions Pilot To Select Heating Level Burner PatternsTo Turn OFF GAS to Appliance Manual Lighting ProcedureInspecting Burner Pilot Flame PatternBurner Flame Pattern Correct Burner Flame PatternCabinet Cleaning and Maintenance Trouble ShootingODS/PILOT and Burner Orifice Air PassagewaysFlame to go out. This Control knob set be Technical Service Ing statement atTop Service Hints Replacement Parts Parts Under WarrantyParts Not Under Warranty Parts Centrals Service Publications Accessory Valve GA5010Parts List Illustrated Parts BreakdownWarranty Information International