Desa CGN12 installation manual Checking GAS Connections, Pressure Testing GAS Supply Piping System

Page 10

IMPORTANT: Hold pressure regulator with wrench when connecting it to gas piping and/or fittings.

3/8" NPT Pipe Nipple

Ground Joint Union

Manual

Shutoff Valve *

From Gas Meter (4" W.C. to

10.5" W.C. Pressure)

3" Minimum

Pressure

Regulator

Heater

Cabinet

Tee Joint

 

 

 

 

 

 

 

 

Reducer

 

Test

Bushing to

 

Gauge

 

1/8" NPT

Connection *

 

 

 

1/8" NPT

 

 

Plug Tap

 

 

 

Tee

 

 

 

Joint

 

Sediment

Pipe

 

 

Trap

Nipple

 

 

 

Cap

 

 

 

CHECKING GAS CONNECTIONS

10

Figure 10 - Gas Connection

*An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See ACCESSORY, page 22.

!WARNING

Test all gas piping and connections for leaks after installing or servicing. Correct all leaks at once.

!WARNING

Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM

Test Pressures In Excess Of 1/2 PSIG

1. Disconnect heater and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator.

2. Cap off open end of gas pipe where manual shutoff valve was connected.

3. Pressurize supply piping system by either using compressed air or

opening main gas valve located on or near gas meter.

Continued

Image 10
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information Safety Information Product Identification Local Codes Unpacking Product FeaturesSafety Device Piezo Ignition SystemCheck GAS Type Installation ItemsLocating Heater Installing Heater to Wall Marking Screw LocationsInstalling Two Mounting Screws Folding AnchorPlacing Heater On Mounting Screws Connecting to GAS Supply Pressure Testing GAS Supply Piping System Checking GAS ConnectionsPressure Testing Heater GAS Connections Manual Shutoff ValveOperating Heater For Your Safety Read Before LightingLighting Instructions Pilot To Select Heating Level Burner PatternsTo Turn OFF GAS to Appliance Manual Lighting ProcedureInspecting Burner Pilot Flame PatternBurner Flame Pattern Correct Burner Flame PatternCabinet Cleaning and Maintenance Trouble ShootingODS/PILOT and Burner Orifice Air PassagewaysFlame to go out. This Control knob set be Ing statement at Technical ServiceTop Parts Under Warranty Service Hints Replacement PartsParts Not Under Warranty Parts Centrals Service Publications Accessory Valve GA5010Parts List Illustrated Parts BreakdownWarranty Information International