Desa BHDV41PC, BHDV41NC Installing GAS Piping to Fireplace Location, Installation Items Needed

Page 18

®

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)

FIREPLACE INSTALLATION

Continued

INSTALLING GAS PIPING TO FIREPLACE LOCATION

WARNING: A qualified ser- vice person must connect fire- place to gas supply. Follow all local codes.

CAUTION: For propane/LP units, never connect heater di- rectly to the propane/LP supply. This heater requires an external regulator (not supplied). Install the external regulator between the heater and propane/LP supply.

Installation Items Needed

Before installing fireplace, make sure you have the items listed below.

external regulator (supplied by installer)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

test gauge connection *

sediment trap

tee joint

pipe wrench

CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to fireplace. If pipe is too small, undue loss of pressure will occur.

Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 35).

Propane/LP

Supply Tank

External

Regulator

Vent

Pointing

Down

Figure 34 - External Regulator with Vent Pointing Down (Propane/LP Only)

CSA/AGA Design-Certified Equipment Shutoff Valve with 1/8" NPT Tap*

IMPORTANT: Install equipment shutoff valve in an accessible location. The equip- ment shutoff valve is for turning on and shutting off the gas to the appliance.

Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces.

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves.

CAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.

We recommend that you install a sediment trap/drip leg in supply line as shown in Figure 35. Locate sediment trap/drip leg where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap/drip leg where trapped matter is not likely to freeze. A sediment trap traps moisture and contami- nants. This keeps them from going into fireplace gas controls. If sediment trap/drip leg is not installed or is installed wrong, fireplace may not run properly.

approved flexible gas line with gas con- nector (if allowed by local codes) (not provided)

*An CSA/AGA design-certified equip- ment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connec- tion. Purchase the CSA/AGA design-certi- fied equipment shutoff valve from your dealer.

For propane/LP connections only, the in- staller must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of

Approved Flexible

Gas Line

3" Minimum

Natural - From Gas Meter (5" W.C. to 10.5" W.C. Pressure )

Propane/LP - From External Regulator (11" W.C. to 14" W.C. Pressure)

water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 34. Pointing the vent down protects it from freezing rain or sleet.

Cap Pipe Nipple Tee Joint

Sediment Trap/Drip Leg

Figure 35 - Gas Connection

*The CSA/AGA design-certified equipment shutoff valve may be supplied with the appliance or you can purchase it from your dealer.

18

106517

Image 18
Contents For Your Safety For Your Safety What to do if YOU Smell GASBHDV37NC, BHDV37PC BHDV41NC, and BHDV41PC Safety Information DIRECT-VENT Fireplace NATURAL/PROPANE/LPGlossary Terms Product FeaturesProduct Identification Local CodesLocation and Space Requirements PRE-INSTALLATION PreparationClearances Framing and FinishingPRE-INSTALLATION Preparation General Venting Location of Vent TerminationGeneral Venting Installation Planning Venting InstallationInstallation Precautions Installing Vent System in a ChaseInstallation for Horizontal Termination Snorkel TerminationVent Pipe Connections Horizontal Termination Configurations Horizontal VentingVenting with Two 90 Elbows Installation for Vertical Termination Flat Ceiling InstallationCathedral Ceiling Installation Vertical Termination Configurations Venting with One 90 ElbowVertical Venting Venting InstallationParts Lists for Venting High AltitudeInstalling GA3700/DA3610TA Blowers Fireplace InstallationInstalling Optional Blower Accessory Check GAS TypeSide View Installing GAS Piping to Fireplace Location Installation Items NeededConnecting Fireplace to GAS Supply Pressure Testing Gas Supply Piping SystemChecking GAS Connections Pressure Testing Fireplace Gas Connections Close equipment shutoff valve see Fig- ureInstalling Optional Wall Mounted Thermostat GWMT1 Installing Optional Wall Mount Switch GWMS2REMOVING/REPLACING Glass Door Removing/Replacing Glass DoorInstalling Optional Brick Liner D8037A/D8041 Installing Left Side Brick PanelInstalling LOGS, Lava Rock and Glowing Embers Installing Log NoOperating Fireplace Operating Optional Blower Accessory Ghrc Series OperationGhrcta Series Operation Inspecting Burners Operating Optional GWMS2 Wall Mounted SwitchPilot Assembly Operating Optional GWMT1 Wall Mounted ThermostatPilot and Burners Cleaning and MaintenanceGlass Door LogsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement Wiring Diagram Replacement PartsTechnical Service Service HintsSpecifications BHDV37NC BHDV37PC BHDV41NC BHDV41PCIllustrated Parts Breakdown BHDV37NC BHDV41NC36Parts List DIRECT-VENT Fireplace BHDV37NC BHDV41NCBHDV37PC BHDV41PC36 DIRECT-VENT Fireplace BHDV37PC BHDV41PC Accessories Cabinet Mantel with Square LEG Styling Unfinished GM501U37 GM103U41Warranty Information