INSTALLATION
Connecting To Gas Supply (Cont.) Connecting Fireplace To Gas Supply
13
INSTALLATION
Continued
Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves.
We recommend that you install a sediment trap in supply line as shown in Figure 19, page 13 . Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace controls. If sediment trap is not installed or is installed wrong, fireplace may not run properly.
WARNING: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.
2.Apply pipe joint sealant lightly to male threads of gas connec- tor attached to flexible gas line (see Figure 21). Connect flex- ible gas line to flexible gas line attached to gas valve of fire- place (see Figure 21).
3.Check all gas connections for leaks. See Checking Gas Con- nections, page 14.
4.Feed flexible gas line into fireplace base area. Make sure the entire flexible gas line is in fireplace mantel base area.
CAUTION: Avoid damage to regulator. Hold gas regulator with wrench when connecting it to gas piping and/or fittings.
Gas | CSA | |
Control | ||
Equipment Shutoff Valve | ||
| ||
| With 1/8" NPT Tap* |
Outer
Casing
I
H
LO
| O |
NO | F |
F | |
TO | P |
Approved Flexible
Gas Hose
3" Minimum
Figure 19 - Gas Connection
From Gas Meter
(5" W.C.** to 10.5" W.C. Pressure)
Cap Pipe Tee Nipple Joint
Sediment Trap
Equipment
Shut Off
Valve
*Purchase the optional CSA
**Minimum inlet pressure for purpose of input adjustment.
CONNECTING FIREPLACE TO GAS SUPPLY
Figure 20 - Routing Flexible Gas Line
|
| To Fireplace | |
|
| Gas Valve | |
Equipment Shutoff | Gas Connector | ➞ | |
Valve | |||
| |||
|
|
Installation Items Needed
•Phillips screwdriver
•sealant (resistant to propane/LP gas, not provided)
1.Route flexible gas line (provided by installer) from equipment shutoff valve into fireplace through side or rear access holes in outer casing (see Figure 20).
➞
To Gas
Supply
Flexible Gas Line | Flexible Gas Line | |
from Fireplace | ||
from Equipment | ||
Gas Valve | ||
Shutoff Valve | ||
Provided with | ||
Provided by | ||
Fireplace | ||
Installer | ||
|
NOTICE: Most building codes do not permit con- cealed gas connections. A flexible gas line is pro- vided to allow accessibility from the fireplace (see Figure 21). The flexible gas supply line connection to the equipment shutoff valve should be accessible.
Figure 21 - Attaching Flexible Gas Lines Together