Desa CF26NR Lighting Instructions, To Turn OFF GAS To Appliance, Manual Lighting Procedure

Page 17

OPERATING FIREPLACE

Lighting Instructions

To Turn Off Gas To Appliance

Manual Lighting Procedure

17

OPERATING FIREPLACE

Continued

LIGHTING

INSTRUCTIONS

NOTICE: During initial operation of new heater, burn- ing logs will give off a paper-burning smell. Open a window to vent smell. This will only last a few hours.

1.STOP! Read the safety information on page 16, column 2.

2.Make sure equipment shutoff valve is fully open.

3.Set switch in OFF position.

WARNING: Burner will come on automatically within one minute when the selector switch is in the ON position after the pilot is lit.

4.Press in and turn control knob clockwise to the OFF position.

5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information on page 16, column 2. If you don’t smell gas, go to the next step.

6.Press in and turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 32).

Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will al- low air to bleed from the gas system.

7.With control knob pressed in, press and release ignitor but- ton. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

8.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs. Note: If pilot goes out, repeat steps 4 through 8.

Selector Switch

Flame Adjustment Knob

AUTO

IH

 

 

O

OFF

 

 

F

ON

N

F

O

P

 

LO

LI

 

TO

Ignitor Button

Control Knob

Figure 32 - Control Knob and Ignitor Button Location (Shown as Supplied, No Control Options)

9.Slightly push in and turn control knob counterclockwise to the ON position.

10.Wait one minute and switch selector switch to the ON posi- tion to light burner.

11.Set flame adjustment knob to any level between HI and LO.

CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.

WARNING: Make sure the selector switch is in the OFF position when you are away from home for long periods of time. Heater will come on automatically with selector switch in the ON position.

Pilot Burner

Ignitor

 

Electrode

Figure 33 - Pilot

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise to the OFF position.

2a. Set selector switch in the OFF position

2b. If Using Optional Hand-Held Remote: Set selector switch in the OFF position to keep from draining battery.

Shutting Off Burner Only (pilot stays lit)

You may shut off the burner and keep the pilot lit by doing one of the following:

1.Turn control knob clockwise to the PILOT position.

2.Use remote control manual OFF button.

3.Set selector switch in the OFF position.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 6 under Lighting Instructions.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow steps 9 through 11 under Lighting Instructions.

For morevisit www..com

105443-01E

Image 17 Contents
What to do if YOU Smell GAS OWNER’S Operation and Installation ManualUnvented VENT-FREE Natural GAS BAY Front Fireplace Safety Information Table of ContentsLocal Codes Product IdentificationRemote Control Accessories Product FeaturesUnpacking AIR for Combustion and VentilationDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Fireplace LocationConfined and Unconfined Space Ventilation AIR InstallationCheck GAS Type Ventilation Air From Inside BuildingLocating Fireplace BUILT-IN Fireplace InstallationRough Opening for Installing in Wall Optional Mantel Installation Mantel Clearances for BUILT-IN InstallationAssembling Brass Trim Removing Brick Liner RetainerRemoving Hood Screws Installing Blower Assembly GA3450TPlace log set back on the unit For Built-In InstallationInstallation Items Connecting to GAS SupplyInstallation Items Needed Connecting Fireplace to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Gas Connections Cghrc & Cghrct Series Installing Receiver Installing LogsOptional Wireless HAND-HELD Remote Control Accessories For Your Safety Read Before Lighting Installing Wireless Remote Control AccessoryInstalling 9-Volt Battery in Receiver Operating FireplaceLighting Instructions Manual Lighting ProcedureTo Turn OFF GAS To Appliance Shutting Off HeaterThermostat Control Operation Optional Remote OperationCghrc Series Operation Cghrcta Series OperationInspecting Burners Cleaning MaintenanceWiring Diagram SpecificationsCabinet Air PassagewaysObserved Problem Possible Cause Remedy TroubleshootingRefer to Air for Combustion and Venti Top CF26NR Illustrated Parts BreakdownKEY Part Number Description QTY Parts List20-1 11-1 11-2 20-2 20-3 KEY CF26NR Description QTY Technical Service Replacement PartsService Hints Parts CentralsOwners Registration Form Tape Information Video Receiver and HAND-HELD Remote Control KIT Cghrc SeriesBrass Accent Trim GA6095 Warranty Information
Related manuals
Manual 32 pages 21.74 Kb