Desa CF26NR installation manual Locating Fireplace, BUILT-IN Fireplace Installation

Page 7

INSTALLATION

Locating Fireplace Built-In Fireplace Installation

7

INSTALLATION

Continued

LOCATING FIREPLACE

WARNING: Maintain the minimum clearances shown in Figure 4. If you can, provide greater clear- ances from floor, ceiling, and joining wall.

You can recess firebox into the wall. You can also position fireplace in the optional cabinet mantels. IMPORTANT: Only use optional cabinet mantels specified in this manual. Purchase the optional mantel from your dealer (see Accessories, page 31).

WARNING: Never install the fireplace

in a bedroom or a bathroom

in a recreational vehicle

where curtains, furniture, clothing, or other flam- mable objects are less than 42 inches from the front, top, or sides of the fireplace

as a fireplace insert

in high traffic areas

in windy or drafty areas

CAUTION: This fireplace creates warm air cur- rents. These currents move heat to wall surfaces next to fireplace. Installing fireplace next to vinyl or cloth wall coverings or operating fireplace where impuri- ties (such as, but not limited to, tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.

IMPORTANT: Vent-free fireplaces add moisture to the air. Although this is beneficial, installing fireplace in rooms without enough venti- lation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, pages 4 through 6.

CAUTION: If you install the fireplace in a home garage

fireplace pilot and burner must be at least 18 inches above floor.

locate fireplace where moving vehicle will not hit it.

For convenience and efficiency, install fireplace

where there is easy access for operation, inspection, and service.

in coldest part of room.

An optional blower kit is available from your dealer. See Accesso- ries, page 31. If planning to use blower, locate fireplace near an electrical outlet.

Minimum Clearances For Side Combustible Material, Side Wall, and Ceiling

A.Clearances from the side of the fireplace cabinet to any com- bustible material and wall should follow diagram in Figure 4.

Example: The face of a mantel, bookshelf, etc. is made of combustible material and protrudes 3 1/2" from the wall. This combustible material must be 4" from the side of the fireplace opening (see Figure 4).

B.Clearances from the top of the fireplace opening to the ceiling should not be less than 42 inches.

Example

*

*Minimum 16 inches from Side Wall

Figure 4 - Minimum Clearance for Combustible to Wall

BUILT-IN FIREPLACE INSTALLATION

Built-in installation of this fireplace involves installing fireplace into a framed-in enclosure. This makes the front of fireplace flush with wall. Follow the instructions below to install the fireplace in this manner. If installing a built-in mantel above the fireplace, you must follow the clearances shown in Figure 8, page 9.

Note: If desired, purchase a four-sided brass trim kit for built-in installations. See Accessories, page 31.

 

Actual

Framing

 

 

 

Height

26"

26 7/8"

Front Width

26 3/4"

26 7/8"

Depth

9 1/2"

10 1/2"

Bottom

3/4"

3/4"

 

 

 

1.Frame in rough opening. Use dimensions shown in Figure 5, page 8, for the rough opening.

If installing in a corner, use dimensions shown in Figure 6, page 8, for the rough opening. The height is 26 1/8" which is the same as the wall opening above.

For morevisit www..com

105443-01E

Image 7 Contents
Unvented VENT-FREE Natural GAS BAY Front Fireplace OWNER’S Operation and Installation ManualWhat to do if YOU Smell GAS Safety Information Table of ContentsLocal Codes Product IdentificationAIR for Combustion and Ventilation Product FeaturesRemote Control Accessories UnpackingConfined and Unconfined Space Determining FRESH-AIR Flow for Fireplace LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building InstallationVentilation AIR Check GAS TypeLocating Fireplace BUILT-IN Fireplace InstallationRough Opening for Installing in Wall Removing Brick Liner Retainer Mantel Clearances for BUILT-IN InstallationOptional Mantel Installation Assembling Brass TrimRemoving Hood Screws Installing Blower Assembly GA3450TPlace log set back on the unit For Built-In InstallationInstallation Items Connecting to GAS SupplyInstallation Items Needed Connecting Fireplace to GAS SupplyPressure Testing Fireplace Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Optional Wireless HAND-HELD Remote Control Accessories Installing LogsCghrc & Cghrct Series Installing Receiver Operating Fireplace Installing Wireless Remote Control AccessoryFor Your Safety Read Before Lighting Installing 9-Volt Battery in ReceiverShutting Off Heater Manual Lighting ProcedureLighting Instructions To Turn OFF GAS To ApplianceCghrcta Series Operation Optional Remote OperationThermostat Control Operation Cghrc Series OperationInspecting Burners Cleaning MaintenanceAir Passageways SpecificationsWiring Diagram CabinetObserved Problem Possible Cause Remedy TroubleshootingRefer to Air for Combustion and Venti Top CF26NR Illustrated Parts BreakdownKEY Part Number Description QTY Parts List20-1 11-1 11-2 20-2 20-3 KEY CF26NR Description QTY Parts Centrals Replacement PartsTechnical Service Service HintsOwners Registration Form Tape Brass Accent Trim GA6095 Receiver and HAND-HELD Remote Control KIT Cghrc SeriesInformation Video Warranty Information