Desa VI33PR Optional Wireless HAND- Held Remote Control Accessories, Installing 9-VOLT Batteries

Page 13

OWNER’S MANUAL

INSTALLATION

Continued

2.Install fireplace insert screen by slip- ping notches of fireplace insert screen over screws on front of fireplace insert (see Figure 25).

WARNING: You must operate this fireplace insert with the fire- place insert screen in place. Make sure fireplace insert screen is in place before running fireplace insert.

Notches

Screws for

Mounting Screen

Figure 25 - Installing Fireplace Insert Screen

OPTIONAL WIRELESS HAND- HELD REMOTE CONTROL ACCESSORIES

(GHRC and GHRCT)

Installing Remote Receiver Unit

1.

Disconnect switch wires from the con-

 

trol valve.

2.

Remove screws attaching switchplate.

3.

Remove switch plate (see Figure 26).

 

Discard after removing.

4.

Install remote receiver unit onto gas log

 

heater base using mounting clips.

Remote Switch

Ignitor

Bracket

 

Screw

Switch Plate

Wires

Figure 26 - Switch Plate and Wiring Harness

Mounting

Clips

Remote Receiver

Figure 27 - Installing Remote Receiver

White Wire

From Receiver

Valve

Red Wire From

Receiver

Figure 28 - Connecting Wires

INSTALLING 9-VOLT

BATTERIES

Two 9-volt batteries (not included) are re- quired to operate this heater with the wire- less hand-held remote control set. Install one battery in the receiver and one in the hand-held remote control unit. Note: Only

2.Locate the battery clip mounted on the back of the receiver.

3.Slide a 9-volt battery through the clip.

4.Attach the terminal wires to the battery.

Remote

Receiver

Terminal Wires

Battery Clip

9-Volt Battery

Figure 29 - Installing Battery in Remote Receiver

Installing 9-Volt Battery (Not

Included) in Hand-Held Remote

Control Unit

1.Remove battery cover on back of re- mote control unit.

2.Attach terminal wires to the battery. Place battery into the battery housing.

3.Replace battery cover onto remote con- trol unit.

 

Battery

Remote

Terminal

Control Unit

Cover

Wires

 

 

 

9-Volt

 

 

Battery

 

 

Battery

Housing

Figure 30 - Installing Battery in Hand- Held Remote Control Unit (GHRC Series)

9-Volt Terminal

Battery Wires

5.

Push clips firmly into place (see Fig-

 

ure 27).

6.

Connect wires as shown in Figure 28.

use alkaline batteries.

Installing 9-Volt Battery (Not Included) in Receiver

Battery Cover

Remote

Control

Unit

1.Locate back of receiver under front burner of heater.

Figure 31 - Installing Battery in Hand-Held Remote Control Unit (GHRCTA Series)

105648

13

For more information, visit www.desatech.com

Image 13
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualDesa International Unvented PROPANE/LP GAS Fireplace Insert Safety InformationLocal Codes Remote Control AccessoriesUnpacking Product Identification AIR for Combustion and Ventilation Product FeaturesDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Ventilation AIRBuilding Ventilation Air From OutdoorsInstalling Surround KIT InstallationCheck GAS Type Blower Electrical HookupInstallation Clearances Installing HoodFireplace Insert Installation Into FRAMED-IN Enclosure Fireplace Insert Installation Into Masonry FireplaceConnecting Fireplace Insert to GAS Supply Installing GAS Piping to Fireplace LocationMantel Clearances for Insert Installation Installation Items NeededChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Insert Gas Connections Installing LogsInstalling 9-VOLT Batteries Optional Wireless HAND- Held Remote Control AccessoriesInstalling Remote Receiver Unit Installing 9-Volt Battery Not Included in ReceiverOperating Fireplace Insert For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To Appliance Manual Lighting ProcedureOptional Remote Operation Inspecting Burners Observed Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Specifications Wiring DiagramService Hints Replacement PartsCleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceLogs Remote Ready Model VI33PR Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListFireplace Insert VI33PR Magnet Catch Accessories 105648 Warranty Information