Desa VI33PR installation manual Installing Hood, Installation Clearances

Page 8

DESA INTERNATIONAL

UNVENTED PROPANE/LP GAS FIREPLACE INSERT

INSTALLATION

Continued

4.Using Phillips screwdriver, remove four screws attaching brass louver. In- stall one Phillips head screw (included with kit) in each side (see Figure 7).

5.Align top panel screw holes. Install four Phillips screws, do not tighten.

6.For model GS43, align six screw holes in side panels with holes in top panel (see Figure 9). For model GS38, align two screw holes in side panels with holes in top panel (see Figure 9). Insert and tighten screws.

7.Carefully inspect fireplace surround assembly. Make sure each part fits properly. Firmly tighten all screws in- stalled during assembly.

CAUTION: Do not overtighten. Metal can bend, warp, or break under excessive strain.

Phillips Screws

Brass Louver

Figure 7 - Remove Brass Louver

Top

 

Surround

Louver Screw Holes

Panel

 

Phillips

Screws (4)

Figure 8 - Attaching Top Surround Panel

8.Remove three pieces of brass trim from packaging.

9.Locate four brass screws, two adjust- ing plates with set screws, and two shims in the brass hardware packet.

10.Align shim under adjusting plate as shown in Figure 10.

11.Slide one end of adjusting plate/shim in slot of top brass trim (see Figure 10).

12.Slide other end of adjusting plate/shim in slot on mitered edge of side brass trim (see Figure 10).

13.While firmly holding edges of brass trim together, tighten both set screws on the adjusting plate with slotted screwdriver.

14.Repeat for other side.

15.Line up holes in brass trim with holes on side panels of fireplace surround as- sembly. Attach with brass-plated screws.

16.Move fireplace insert and surround as- sembly to masonry fireplace opening. Make sure fireplace insert and surround assembly fit properly.

Top Panel

Side Panel

Figure 9 - Attaching Side Panels to Top Panel (GS43 Pictured)

Set Screws

Side Brass

Top Brass

Trim

Trim

 

Adjusting

 

Plate

 

Shim

 

Slot

Mitered

Slot

Edge

 

 

 

Figure 10 - Assembling Brass Trim

INSTALLING HOOD

Install hood to top of firebox as shown in Figure 11. Use 7 Phillips screws provided.

Screws

Figure 11 - Installing Hood to Firebox

INSTALLATION

CLEARANCES

WARNING: Maintain the mini- mum clearances. If you can, pro- vide greater clearances from floor, ceiling, and adjoining wall.

Carefully follow the instructions below. This will ensure safe installation.

Minimum Clearances For Side

Combustible Material, Side Wall,

and Ceiling

A.Clearances from the side of the fireplace cabinet to any combustible material and wall should follow diagram in Figure 12.

Example:The face of a mantel, bookshelf, etc. is made of combustible material and protrudes 3 1/2" from the wall. This com- bustible material must be 4" from the side of the fireplace opening (see Figure 12).

B.Clearances from the top of the fireplace opening to the ceiling should not be less than 42 inches.

 

 

 

 

 

 

 

 

 

 

121/4

 

 

 

 

 

 

 

 

 

 

 

101/2

 

 

Example

 

 

 

 

 

8 3/4

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

INCHES

 

 

 

 

 

 

 

 

 

 

51/4

 

 

 

 

 

 

 

 

 

 

31/2

 

 

 

 

 

 

 

 

 

 

13/4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7/8

 

 

 

 

 

 

 

 

 

 

 

7/16

 

FIREBOX

.5

1

2

4

6

8

10

12

14

16 *

 

 

 

 

 

INCHES

 

 

 

 

 

*Minimum 16 inches from Side Wall

Figure 12 - Minimum Clearance for Combustible to Wall

For more information, visit www.desatech.com

8

105648

Image 8
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASSafety Information Desa International Unvented PROPANE/LP GAS Fireplace InsertUnpacking Product Identification Remote Control AccessoriesLocal Codes Product Features AIR for Combustion and VentilationDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Ventilation AIR Ventilation Air From InsideBuilding Ventilation Air From OutdoorsInstallation Installing Surround KITCheck GAS Type Blower Electrical HookupInstalling Hood Installation ClearancesFireplace Insert Installation Into Masonry Fireplace Fireplace Insert Installation Into FRAMED-IN EnclosureInstalling GAS Piping to Fireplace Location Connecting Fireplace Insert to GAS SupplyMantel Clearances for Insert Installation Installation Items NeededPressure Testing Gas Supply Piping System Checking GAS ConnectionsInstalling Logs Pressure Testing Fireplace Insert Gas ConnectionsOptional Wireless HAND- Held Remote Control Accessories Installing 9-VOLT BatteriesInstalling Remote Receiver Unit Installing 9-Volt Battery Not Included in ReceiverLighting Instructions For Your Safety Read Before LightingOperating Fireplace Insert Optional Remote Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Inspecting Burners Troubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement Wiring Diagram SpecificationsService Hints Replacement PartsLogs Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Illustrated Parts Breakdown Remote Ready Model VI33PRParts List KEY Part Number Description QTYFireplace Insert VI33PR Magnet Catch Accessories 105648 Warranty Information