OWNER’S MANUAL

INSTALLATION

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your pri- mary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

WARNING: A qualified ser- vice person must install fireplace insert. Follow all local codes.

WARNING: Never install the fireplace insert

in a bedroom or bathroom

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 42 inches from the front, top, or sides of the fireplace insert

in high traffic areas

in windy or drafty areas

CAUTION: This fireplace insert creates warm air currents. These currents move heat to wall sur- faces next to fireplace insert. In- stalling fireplace insert next to vi- nyl or cloth wall coverings or oper- ating fireplace insert where impu- rities (such as tobacco smoke, aro- matic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls.

Note: Your Vanguard fireplace insert is de- signed to be used in zero clearance installa- tions. Wall or framing material can be placed directly against any exterior surface on the rear, sides, or top of your fireplace insert, except where standoff spacers are integrally attached. If standoff spacers are attached to your insert, these spacers can be placed di- rectly against wall or framing materials.

IMPORTANT: Vent-free heaters add mois- ture to the air. Although this is beneficial, installing fireplace in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Com- bustion and Ventilation, pages 4 through 6.

IMPORTANT: Make sure the fireplace in- sert is level. If fireplace insert is not level, log set will not work properly.

CHECK GAS TYPE

Use only propane/LP gas. If your gas supply is not propane/LP gas, do not install fireplace insert. Call dealer where you bought fire- place insert for proper type fireplace insert.

BLOWER ELECTRICAL HOOKUP

This fireplace insert includes a blower assem- bly with an electrical cord. The electrical cord is five feet in length. You must locate fireplace insert within reach of a 120 volt grounded electrical outlet. If not, install and properly ground GA3555, three-prong 120 volt electri- cal outlet, in fireplace insert. Follow instruc- tions included in kit (see Accessories, page 26).

INSTALLING SURROUND KIT

(GS38 or GS43)

CAUTION: Close masonry fireplace damper securely before installing fireplace insert. If chim- ney does not have a damper, block or cap top of chimney. Fail- ure to cap an open chimney could cause drafts that can affect the heater’s performance and in- crease surface temperatures.

CAUTION: A GS38 or GS43 surround kit accessory must be installed on this fireplace insert beforeinstallingintoyourmasonry fireplace or wall opening.

Note: Use the accessory which best covers the existing masonry fireplace opening or wall opening.

Model GS38 Surround Kit (for use with fireplaces with an opening smaller than 30" H and 38" W)

Model GS43 Surround Kit (for use with fireplaces with an opening 30" to 36 3/4" H and 38" to 43" W)

1.Using a 5/16" nut driver, remove two shoulder screws and screen (see Fig- ure 5). Remove 5/16" screen mount- ing shoulder screws (do not discard).

2.Remove log packaging from firebox cavity.

3.Align holes in left surround side panel with screen mounting screw holes. Replace 5/ 16" screen mounting shoulder screws re- moved in step 1 (see Figure 6). Do not tighten. Install Phillips screws in bottom (see Figure 6). Repeat for right side.

Screen Mounting

Shoulder Screw (4)

Shoulder

Screw

Figure 5 - Removing Screws and Screen

Surround Side

5/16" Screws

Phillips Screws

Figure 6 - Attaching Left Surround Side

Panel

Continued

105648

7

For more information, visit www.desatech.com

Image 7
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualDesa International Unvented PROPANE/LP GAS Fireplace Insert Safety InformationLocal Codes Remote Control AccessoriesUnpacking Product Identification AIR for Combustion and Ventilation Product FeaturesDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside BuildingBlower Electrical Hookup InstallationInstalling Surround KIT Check GAS TypeInstallation Clearances Installing HoodFireplace Insert Installation Into FRAMED-IN Enclosure Fireplace Insert Installation Into Masonry FireplaceInstallation Items Needed Installing GAS Piping to Fireplace LocationConnecting Fireplace Insert to GAS Supply Mantel Clearances for Insert InstallationChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Insert Gas Connections Installing LogsInstalling 9-Volt Battery Not Included in Receiver Optional Wireless HAND- Held Remote Control AccessoriesInstalling 9-VOLT Batteries Installing Remote Receiver UnitOperating Fireplace Insert For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To Appliance Manual Lighting ProcedureOptional Remote Operation Inspecting Burners Observed Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Replacement Parts Wiring DiagramSpecifications Service HintsCleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceLogs Remote Ready Model VI33PR Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListFireplace Insert VI33PR Magnet Catch Accessories 105648 Warranty Information