OWNER’S MANUAL
OPERATING FIREPLACE INSERT
Continued
WARNING: Make sure the selector switch is in the OFF po- sition when you are away from home for long periods of time. Heater will come on automati- cally with selector switch in the ON position.
Pilot Burner | Ignitor |
| Electrode |
Figure 33 - Pilot
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater
1.Turn control knob clockwise to the OFF position.
2a. Set selector switch in the OFF position.
OPTIONAL REMOTE
OPERATION
Note: All remote control accessories must be purchased separately (see Accessories, page 26). Follow instructions included with the remote control.
Thermostat Control Operation
(Optional GHRCTA Series Only) The thermostat control setting on the remote control unit can be set to any comfort level between WARMER and COOLER. The burners will turn on and off auto- matically to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.
For wall thermostat operation, follow in- struction supplied with thermostat acces- sory GWMT1. For wall switch operation follow instructions supplied with GWMS2.
NOTICE: You must light the pilot before using the
1.After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjust- ment knob anywhere between HI and LO. Slide the remote selector switch to the REMOTE position (see Figure 34). Note: The burners may light if
IMPORTANT: Do not leave the re- mote selector switch in the REMOTE position when the pilot is not lit. This will drain the battery.
IMPORTANT: Be sure to press the ON/OFF buttons on the
GHRC Series Operation:
2a. Press the ON/OFF button to turn the burners on and off. When turning burners off, the pilot will remain lit.
2b. If Using Optional
Shutting Off Burners Only (pilot stays lit)
You may shut off the burners and keep
Flame Adjustment Knob |
| |||
IH |
| P |
|
|
F | IL |
| ||
|
| O |
| |
| F |
| T |
|
| O |
|
| |
|
|
|
| |
|
|
| O |
|
|
|
| N | ON |
|
|
|
| |
LO |
|
|
| OFF |
REMOTE
Control Knob in
the pilot lit by doing one of the following:
• Turn control knob clockwise |
On Position
Remote Selector Switch in Remote Position (Optional Remote Control)
to the PILOT position. |
• Use remote control manual OFF button. |
Figure 34 - Setting the Remote Selector Switch, Control Knob, and Flame Adjustment Knob for Remote Operation
• Set remote selector switch in the OFF |
position. |
MANUAL LIGHTING
PROCEDURE
1. | Follow steps 1 through 6 under Light- |
| ing Instructions, page 14. |
2. | Depress control knob and light pilot |
| with match. |
3. | Keep control knob pressed in for 30 |
| seconds after lighting pilot. After 30 |
Shows Temperature Setting
The Log Heater will Automatically Cycle between Pilot and the Heat Setting that has been Selected
Increases Room
Temperature in
AUTO Mode
Decreases Room
Temperature in
AUTO Mode
Turns Burners On or Off and Allows You to Choose the Auto Setting
seconds, release control knob. Now |
follow steps 9 through 11, page 14. |
Figure 35 - Thermostat Hand-Held Remote Control Unit Selections (GHRCTA Series only)
Continued
105648 | 15 | For more information, visit www.desatech.com |