Desa VI33PR Wiring Diagram, Specifications, Service Hints, Replacement Parts, Technical Service

Page 20

DESA INTERNATIONAL

UNVENTED PROPANE/LP GAS FIREPLACE INSERT

WIRING DIAGRAM

Note: For proper operation of optional ac- cessories, the wires from the switch to the control must be connected exactly as shown in Figure 40.

AUTO

OFF

ON

Figure 40 - Switch Wiring Diagram

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous opera- tion. Verify proper operation af- ter servicing.

Variable

Fan SwitchFan Switch

(N.O.)

Off 1

2 Black

On Blue

Red

110/115

V.A.C.

Black

Green

Blower

White

Motor

Figure 41 - Blower Wiring Diagram

Thermopile

SPECIFICATIONS

VI33PR Remote Ready Insert

Btu (Variable)

20,000/33,000

Type Gas

Propane/LP Only

Ignition

Piezo

Pressure Manifold

8.0" W.C.

Inlet Gas Pressure (in. of water)

Maximum

14"

Minimum*

11"

* For input adjustment

 

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

heater will not produce specified heat

propane/LP gas supply may be low

When Gas Quality Is Bad

pilot will not stay lit

burners will produce flames and soot

heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane/LP gas supplier.

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Techni- cal Service Department at 1-800-323-5190. When calling DESA International, have ready

your name and address

model and serial numbers of your heater

how heater was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the defec- tive part to the factory.

PARTS NOT UNDER

WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Parts Department at 1-800-972-7879 for referral information. When calling DESA Interna- tional, have ready

model number of your heater

the replacement part number

TECHNICAL

SERVICE

You may have further questions about in- stallation, operation, or troubleshooting.

If so, contact DESA International’s Techni- cal Service Department at 1-800-DESA LOG (1-800-337-2564).

You can also visit DESA International’s technical service web site at www.desatech.com.

For more information, visit www.desatech.com

20

105648

Image 20
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASSafety Information Desa International Unvented PROPANE/LP GAS Fireplace InsertUnpacking Product Identification Remote Control AccessoriesLocal Codes Product Features AIR for Combustion and VentilationDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Ventilation AIR Ventilation Air From InsideBuilding Ventilation Air From OutdoorsInstallation Installing Surround KITCheck GAS Type Blower Electrical HookupInstalling Hood Installation ClearancesFireplace Insert Installation Into Masonry Fireplace Fireplace Insert Installation Into FRAMED-IN EnclosureInstalling GAS Piping to Fireplace Location Connecting Fireplace Insert to GAS SupplyMantel Clearances for Insert Installation Installation Items NeededPressure Testing Gas Supply Piping System Checking GAS ConnectionsInstalling Logs Pressure Testing Fireplace Insert Gas ConnectionsOptional Wireless HAND- Held Remote Control Accessories Installing 9-VOLT BatteriesInstalling Remote Receiver Unit Installing 9-Volt Battery Not Included in ReceiverLighting Instructions For Your Safety Read Before LightingOperating Fireplace Insert Optional Remote Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Inspecting Burners Troubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement Wiring Diagram SpecificationsService Hints Replacement PartsLogs Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Illustrated Parts Breakdown Remote Ready Model VI33PRParts List KEY Part Number Description QTYFireplace Insert VI33PR Magnet Catch Accessories 105648 Warranty Information