OPERATING FIREPLACE INSERT

Lighting Instructions (Cont.)

To Turn Off Gas To Appliance

Manual Lighting Procedure

OPERATING FIREPLACE INSERT

Continued

4.Press in and turn control knob clockwise to the OFF position.

5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information in column 2, page 15. If you don’t smell gas, go to the next step.

6.Press in and turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 32).

Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will al- low air to bleed from the gas system.

7.With control knob pressed in, press and release ignitor but- ton. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

8.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs. Note: If pilot goes out, repeat steps 4 through 8.

9.Slightly push in and turn control knob counterclockwise to the ON position.

10.Wait one minute and switch selector switch to the ON posi- tion to light burners.

11.Set flame adjustment knob to any level between HI and LO.

CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.

Ignitor Button

 

IH

 

 

 

 

 

O

 

 

 

F

AUTO

N

 

F

O

TOL

P

OFF

LO

 

 

I

 

 

 

 

ON

WARNING: Make sure the selector switch is in the OFF position when you are away from home for long periods of time. Heater will come on automatically with selector switch in the ON position.

Pilot

Ignitor

Pilot

Ignitor

Burner

Electrode

Burner

Electrode

Natural Gas

Propane/LP Gas

Figure 33 - Pilot

TO TURN OFF GAS TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise to the OFF position.

2a. Set selector switch in the OFF position.

2b. If Using Optional Hand-Held Remote: Set remote selector switch in the OFF position to keep from draining battery.

Shutting Off Burners Only (pilot stays lit)

You may shut off the burners and keep the pilot lit by doing one of the following:

Turn control knob clockwise to the PILOT position.

Use remote control manual OFF button.

Set remote selector switch in the OFF position.

MANUAL LIGHTING PROCEDURE

1.Follow steps 1 through 6 under Lighting Instructions, page 15 and column 1.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow steps 9 through 11, column 1.

Flame Adjustment

Control Knob

Selector Switch

Knob

 

 

 

Figure 32 - Control Knob and Ignitor Button Location (Shown as

Supplied, No Control Options)

For..com

110150-01A

Image 16
Contents Unvented VENT-FREE GAS Fireplace Insert OWNER’S Operation and Installation ManualWhat to do if YOU Smell GAS Table of Contents Safety InformationLog Base Assembly Product IdentificationRemote Control Accessories Product FeaturesLocal Codes UnpackingProviding Adequate Ventilation Determining FRESH-AIR Flow for Heater LocationUnusually Tight Construction Confined and Unconfined SpaceVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Installing Surround KIT GS38 or GS43Blower Accessory Check GAS TypeInstalling Hood Attaching LeftInstallation Clearances Fireplace Insert Installation Into Masonry FireplaceFireplace Insert Installation Into FRAMED-IN Enclosure Installing GAS Piping to Fireplace LocationMantel Clearances for Insert Installation Installation Items NeededConnecting Fireplace Insert to GAS Supply Propane/LPPressure Testing Gas Supply Piping System Checking GAS Connections Installing Logs Pressure Testing Fireplace Insert Gas ConnectionsInstalling Remote Receiver Unit GhrctaInstalling 9-VOLT Batteries For Your Safety Read Before LightingInstalling 9-Volt Battery Not Included in Receiver Operating Fireplace InsertManual Lighting Procedure To Turn OFF GAS to ApplianceShutting Off Heater Shutting Off Burners Only pilot stays litOptional Remote Operation Thermostat Control OperationGhrc Series Operation Ghrcta Series OperationInspecting Burners Cleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceLogs Troubleshooting Observed Problem Possible CauseMaintenance, Observed Problem Possible Cause Remedy Wiring Diagrams Replacement PartsService Hints SpecificationsIllustrated Parts Breakdown Remote Ready Model VI33NRAParts List KEY Part Number Description QTYRemote Ready Model VI33PRA 103877-01 Lighting Instruction Plate 100563-01 Fireplace Insert VI33NRA VI33PRA 101784-01 Magnet Catch 102307-01 Strike Plate Receiver and HAND-HELD Remote Control KIT Ghrc Series WALL-MOUNT Thermostat SwitchWALL-MOUNT ON/OFF Switch GWMS2 Cleaning KIT CCK110150-01A Warranty Information