Desa VI33PRA Wiring Diagrams, Replacement Parts, Service Hints, Specifications, Technical Service

Page 23

WIRING DIAGRAMS

Note: For proper operation of optional accessories, the wires from the switch to the control must be connected exactly as shown in Figure 42.

A

 

UTO

OF

O

F

N

 

Thermopile

Figure 42 - Switch Wiring Diagram

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

Variable

Fan SwitchFan Switch

(N.O.)

Off 1

2 Black

On Blue

Red

110/115

V.A.C.

Black

Green

Blower

White

Motor

Figure 43 - Blower Wiring Diagram

WIRING DIAGRAMS

SPECIFICATIONS 23

REPLACEMENT PARTS

SERVICE HINTS

TECHNICAL SERVICE

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Technical Service Department at 1-866-672-6040. When calling DESA Inter- national, have ready

your name and address

model and serial numbers of your heater

how heater was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International at 1-866-672-6040 for referral information. When calling DESA International, have ready

model number of your heater

the replacement part number

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

heater will not produce specified heat

for propane/LP unit, propane/LP gas supply may be low

You may feel your gas pressure is low. If so, contact your local gas supplier.

SPECIFICATIONS

 

VI33NRA

VI33PRA

Btu (Variable)

20,000/30,000

20,000/33,000

Type Gas

Natural Gas Only

Propane/LP Only

Ignition

PiezoPiezo

 

Pressure Manifold

3.5" W.C.

8.0" W.C.

Inlet Gas Pressure (in. of water)

 

Maximum

10.5"

14"

Minimum*

5"

11"

* For input adjustment

 

 

TECHNICAL SERVICE

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-866-672-6040. When calling please have your model and serial numbers of your heater ready.

You can also visit DESA International’s technical services web site at www.desatech.com.

For morevisit www..com

110150-01A

Image 23
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualUnvented VENT-FREE GAS Fireplace Insert Safety Information Table of ContentsProduct Identification Log Base AssemblyUnpacking Remote Control AccessoriesProduct Features Local CodesConfined and Unconfined Space Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Unusually Tight ConstructionVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallationInstalling Surround KIT GS38 or GS43 Blower AccessoryAttaching Left Installing HoodFireplace Insert Installation Into Masonry Fireplace Installation ClearancesInstallation Items Needed Fireplace Insert Installation Into FRAMED-IN EnclosureInstalling GAS Piping to Fireplace Location Mantel Clearances for Insert InstallationPropane/LP Connecting Fireplace Insert to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Insert Gas Connections Installing LogsGhrcta Installing Remote Receiver UnitOperating Fireplace Insert Installing 9-VOLT BatteriesFor Your Safety Read Before Lighting Installing 9-Volt Battery Not Included in ReceiverShutting Off Burners Only pilot stays lit Manual Lighting ProcedureTo Turn OFF GAS to Appliance Shutting Off HeaterGhrcta Series Operation Optional Remote OperationThermostat Control Operation Ghrc Series OperationInspecting Burners Logs Cleaning MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Observed Problem Possible Cause TroubleshootingMaintenance, Observed Problem Possible Cause Remedy Specifications Wiring DiagramsReplacement Parts Service HintsRemote Ready Model VI33NRA Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListRemote Ready Model VI33PRA 103877-01 Lighting Instruction Plate 100563-01 Fireplace Insert VI33NRA VI33PRA 101784-01 Magnet Catch 102307-01 Strike Plate Cleaning KIT CCK Receiver and HAND-HELD Remote Control KIT Ghrc SeriesWALL-MOUNT Thermostat Switch WALL-MOUNT ON/OFF Switch GWMS2110150-01A Warranty Information