Desa VI33NRA, VI33PRA installation manual Troubleshooting, Observed Problem Possible Cause

Page 20

20

TROUBLESHOOTING

TROUBLESHOOTING

Note: For additional help, visit DESA International’s technical service web site at www.desatech.com.

Note: All troubleshooting items are listed in order of operation.

WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.

CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed, there is no spark at ODS/pilot

1.Ignitor electrode not connected to igni- tor cable

2.Ignitor cable pinched or wet

3.Piezo ignitor nut is loose

4.Broken ignitor cable

5.Bad piezo ignitor

6.Ignitor electrode broken

7.Ignitor electrode positioned wrong

1.Reconnect ignitor cable

2.Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry

3.Tighten nut holding piezo ignitor to base panel of log set. Nut is located behind base panel

4.Replace ignitor cable

5.Replace piezo ignitor

6.Replace pilot assembly

7.Replace pilot assembly

When ignitor button is pressed, there is spark at ODS/pilot but no ignition

1.Gas supply turned off or equipment shutoff valve closed

2.Control knob not in PILOT position

3.Control knob not pressed in while in PILOT position

4.Air in gas lines when installed

5.Depleted gas supply (propane/LP only)

6.ODS/pilot is clogged

7.Gas regulator setting is not correct

1.Turn on gas supply or open equipment shutoff valve

2.Turn control knob to PILOT position

3.Press in control knob while in PILOT position

4.Continue holding down control knob. Repeat igniting operation until air is removed

5.Contact local propane/LP gas company

6.Clean ODS/pilot (see Cleaning and Maintenance, page 19) or replace ODS/ pilot assembly

7.Replace gas control

ODS/pilot lights but flame goes out when control knob is released

1.Control knob not fully pressed in

2.Control knob not pressed in long enough

3.Equipment shutoff valve not fully open

4.Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This prob- lem could be caused by one or both of the following:

A)Low gas pressure

B)Dirty or partially clogged ODS/pilot

5.Thermocouple connection loose at con- trol valve

6.Thermocouple damaged

7.Control valve damaged

1.Press in control knob fully

2.After ODS/pilot lights, keep control knob pressed in 30 seconds

3.Fully open equipment shutoff valve

4.A) Contact local natural or propane/LP gas company

B) Clean ODS/pilot (see Cleaning and Maintenance, page 19) or replace ODS/ pilot assembly

5.Hand tighten until snug, then tighten 1/4 turn more

6.Replace pilot assembly

7.Replace control valve

For..com

110150-01A

Image 20
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualUnvented VENT-FREE GAS Fireplace Insert Table of Contents Safety InformationLog Base Assembly Product IdentificationRemote Control Accessories Product FeaturesLocal Codes UnpackingProviding Adequate Ventilation Determining FRESH-AIR Flow for Heater LocationUnusually Tight Construction Confined and Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installation Installing Surround KIT GS38 or GS43Blower Accessory Check GAS TypeInstalling Hood Attaching LeftInstallation Clearances Fireplace Insert Installation Into Masonry FireplaceFireplace Insert Installation Into FRAMED-IN Enclosure Installing GAS Piping to Fireplace LocationMantel Clearances for Insert Installation Installation Items NeededConnecting Fireplace Insert to GAS Supply Propane/LPPressure Testing Gas Supply Piping System Checking GAS ConnectionsInstalling Logs Pressure Testing Fireplace Insert Gas ConnectionsInstalling Remote Receiver Unit GhrctaInstalling 9-VOLT Batteries For Your Safety Read Before LightingInstalling 9-Volt Battery Not Included in Receiver Operating Fireplace InsertManual Lighting Procedure To Turn OFF GAS to ApplianceShutting Off Heater Shutting Off Burners Only pilot stays lit Optional Remote Operation Thermostat Control Operation Ghrc Series Operation Ghrcta Series OperationInspecting Burners Logs Cleaning MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Troubleshooting Observed Problem Possible CauseMaintenance, Observed Problem Possible Cause Remedy Wiring Diagrams Replacement PartsService Hints SpecificationsIllustrated Parts Breakdown Remote Ready Model VI33NRAParts List KEY Part Number Description QTYRemote Ready Model VI33PRA 103877-01 Lighting Instruction Plate 100563-01 Fireplace Insert VI33NRA VI33PRA 101784-01 Magnet Catch 102307-01 Strike Plate Receiver and HAND-HELD Remote Control KIT Ghrc Series WALL-MOUNT Thermostat SwitchWALL-MOUNT ON/OFF Switch GWMS2 Cleaning KIT CCK110150-01A Warranty Information