Desa VSGF28NTE, VSGF28PTE installation manual Connecting Fireplace to GAS Supply, Propane/LP

Page 14

INSTALLATION

Continued

CONNECTING FIREPLACE TO GAS SUPPLY

Installation Items Needed

5/16" hex socket wrench or nut-driver

Phillips screwdriver

sealant (resistant to propane/LP gas, not pro- vided)

1.Remove fireplace screen. Remove two screws that hold fireplace screen in place for ship- ping. These screws are located near top of screen. Discard screws. Lift fireplace screen up and pull out to remove.

2.Remove screws that attach log base assembly to fireplace (see Figure 19). Carefully lift up log base assembly and remove from fireplace (see Figure 19).

Note: If adding the G8000 series brick liner ac- cessory, install it now. Follow instructions in G8000 accessory kit.

CAUTION: Do not pick up log base assembly by burners. This could damage burners. Only handle base by grates.

3.Route gas line (provided by installer) from equipment shutoff through one of the access holes.

NOTICE: Most building codes do not permit concealed gas con- nections. A flexible gas line is provided to allow accessibility from the fireplace (see Figure 20). The flexible gas supply line con- nection to the equipment shutoff valve should be accessible.

4.Attach flexible gas line to gas supply (see Fig- ure 20). Check connection of flexible gas line attached to gas regulator of fireplace (see Fig- ure 20).

5.Check all gas connections for leaks. See Checking Gas Connections, page 15.

6.Replace log base assembly back into fireplace. Feed flexible gas line into fireplace base area while replacing log base assembly. Make sure the entire flexible gas line is in fireplace base area. Reattach log base assembly to fireplace with screws removed in step 2.

Figure 19 - Removing Log Base

Assembly From Fireplace

To Fireplace

Flexible Gas Line

Gas Regulator

 

from Equipment

 

Shutoff Valve

Equipment Shutoff Valve

Provided by Installer

Natural Gas

To Gas Meter

Propane/LP

To External Regulator

Figure 20 - Attaching Flexible Gas Lines

Together

14

www.desatech.com

113135-01A

Image 14
Contents ¢QQQQQQ ¢ ¢ ¢ ¢ ¢ Table of Contents Safety Information Local Codes Unpacking Product FeaturesProduct Identification Determining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationProviding Adequate Ventilation Unusually Tight ConstructionVentilation AIR Ventilation Air From Inside BuildingInstallation Ventilation Air From OutdoorsElectrical Hookup Installing HoodCheck GAS Type Installation Clearances Conventional Fireplace InstallationBUILT-IN Fireplace Installation Depth 16 11/16 17 3/4Installing GAS Piping to Fireplace Location Mantel Clearances for Built-In InstallationInstallation Items Needed Natural GasConnecting Fireplace to GAS Supply Propane/LPChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Gas Connections Installing Logs Installing Front Log #1Lighting Instructions For Your Safety Read Before LightingOperating Fireplace Thermostat Control Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Blower OperationFront Burner Flame Pattern Inspecting BurnersPilot Flame Pattern Logs Cleaning MaintenanceBurner Injector Holder and Pilot AIR Inlet Hole Troubleshooting Observed Problem Possible Cause RemedyPress in control knob fully Stalling Logs, Gas leak. See Warning Statement aboveService Hints SpecificationsWiring Diagram Replacement PartsIllustrated Parts Breakdown Parts List LOG Base AssemblyFireplace Models VSGF28NTE and VSGF28PTE KEY Part Number Description QTY Accessories Laminate Trim for Hearth or Mantel Hardwood Hearth BaseCorner Hearth Base Limited Warranty VENT-FREE GAS Fireplace Warranty InformationKeep this Warranty