Desa VSGF28PTE, VSGF28NTE installation manual Product Identification, Unpacking, Product Features

Page 5

PRODUCT

IDENTIFICATION

Middle Log

Rear Burner

 

Rear

Front

Log

Log

 

Front Burner

Figure 1 - Log Base Assembly, Split Oak Set

Top Louver

Top Outer

Assembly

Casing

Fireplace

 

Hood

 

Firebox

 

Support

 

Screen

Assembly

Bottom Louver

Blower

Assembly

Assembly

Figure 2 - Fireplace

UNPACKING

CAUTION: Do not remove the data plates attached to the heater base assembly. The data plates contain important war- ranty and safety information.

1.With utility knife, cut the carton all the way around above the staples on the bottom tray. Lift the carton off the heater. Remove pack- ing. Note: The hood is located in the packing on the right hand side of the heater front. Lift the heater off the bottom tray.

2.Locate two screws above top corners of the fireplace screen. Remove and discard these screws. Lift fireplace screen up and pull out to remove.

3.Remove protective packaging applied to logs, log base assembly, and fireplace.

4.Remove fireplace hood from carton insert.

5.Check all items for any shipping damage. If damaged, promptly inform dealer where you bought fireplace.

PRODUCT FEATURES

OPERATION

This vent-free fireplace is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by both realis- tic flames and glowing embers. When used with- out the blower, the fireplace requires no electric- ity making it ideal for emergency backup heat.

SAFETY DEVICE

This fireplace has a pilot with an Oxygen Deple- tion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot system shuts off the fire- place if there is not enough fresh air.

PIEZO IGNITION SYSTEM

This fireplace has a piezo ignitor. This system re- quires no matches, batteries, or other sources to light fireplace.

BLOWER ASSEMBLY

This fireplace has a blower assembly. The blower operates thermostatically and has a variable speed control. The blower circulates heated air from the fireplace into the room. Use of blower is optional.

THERMOSTAT CONTROL

This fireplace has a thermostat sensing bulb and a control valve. The thermostat controls the heat output and flame height. This maintains a consis- tent room temperature. Even the lowest setting provides realistic flames and glowing embers from two burners. Selecting higher comfort settings al- lows fireplace to run longer, producing greater heat output. At lower comfort settings, the fireplace will run less. This results in increased heating com- fort. This can also result in lower gas￿bills.

113135-01A

www.desatech.com

5

Image 5
Contents ¢QQQQQQ ¢ ¢ ¢ ¢ ¢ Table of Contents Safety Information Local Codes Unpacking Product FeaturesProduct Identification Providing Adequate Ventilation AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Unusually Tight ConstructionVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors InstallationElectrical Hookup Installing HoodCheck GAS Type Conventional Fireplace Installation Installation ClearancesDepth 16 11/16 17 3/4 BUILT-IN Fireplace InstallationMantel Clearances for Built-In Installation Installing GAS Piping to Fireplace LocationNatural Gas Installation Items NeededPropane/LP Connecting Fireplace to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Gas Connections Installing Front Log #1 Installing LogsLighting Instructions For Your Safety Read Before LightingOperating Fireplace To Turn OFF GAS To Appliance Manual Lighting ProcedureThermostat Control Operation Blower OperationFront Burner Flame Pattern Inspecting BurnersPilot Flame Pattern Logs Cleaning MaintenanceBurner Injector Holder and Pilot AIR Inlet Hole Observed Problem Possible Cause Remedy TroubleshootingPress in control knob fully Stalling Logs, Statement above Gas leak. See WarningWiring Diagram SpecificationsService Hints Replacement PartsIllustrated Parts Breakdown LOG Base Assembly Parts ListFireplace Models VSGF28NTE and VSGF28PTE KEY Part Number Description QTY Accessories Laminate Trim for Hearth or Mantel Hardwood Hearth BaseCorner Hearth Base Limited Warranty VENT-FREE GAS Fireplace Warranty InformationKeep this Warranty