Desa VSGF28PTE, VSGF28NTE installation manual Installation Items Needed, Natural Gas

Page 13

INSTALLATION

Continued

Installation Items Needed

Before installing fireplace, make sure you have the items listed below.

external regulator (supplied by installer)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

test gauge connection *

sediment trap (optional)

tee joint

pipe wrench

*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, pages 30 and 31.

For propane/LP units, the installer must supply an external regulator. The external regulator will re- duce incoming gas pressure. You must reduce in- coming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pres- sure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 17. Pointing the vent down pro- tects it from freezing rain or sleet.

CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater

Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could re- sult in clogged fireplace valves.

WARNING: Use pipe joint sealant that is resistant to liq- uid petroleum (LP) gas.

We recommend that you install a sediment trap in supply line as shown in Figure 18. Locate sedi- ment trap where it is within reach for cleaning. Install in piping system between fuel supply and fireplace. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace gas controls. If sediment trap is not installed or is installed wrong, fireplace may not run properly.

External

Propane/LP

Supply Tank

Regulator

 

Vent

Pointing

Down

Figure 17 - External Regulator with Vent

Pointing Down

CSA Design-Certified

Equipment Shutoff Valve

With 1/8" NPT Tap*

to allow proper gas volume to fireplace. If pipe is too small, undue loss of volume will occur.

Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 18).

IMPORTANT: Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance.

3" Minimum

Pipe Tee

Nipple Cap Joint

Sediment Trap

Natural Gas

From Gas Meter (5" w.c. to 10.5" w.c. Pressure

Propane/LP From External Regulator (11"w.c.** to 14"w.c. Pressure)

Check your building codes for any special require- ments for locating equipment shutoff valve to fire- places.

Figure 18 - Gas Connection

*Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Ac- cessories, pages 30 and 31.

**Minimum inlet pressure for purpose of input adjustment.

113135-01A

www.desatech.com

13

Image 13
Contents ¢QQQQQQ ¢ ¢ ¢ ¢ ¢ Table of Contents Safety Information Local Codes Product Identification Product FeaturesUnpacking Providing Adequate Ventilation AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Unusually Tight ConstructionVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors InstallationCheck GAS Type Installing HoodElectrical Hookup Conventional Fireplace Installation Installation ClearancesDepth 16 11/16 17 3/4 BUILT-IN Fireplace InstallationMantel Clearances for Built-In Installation Installing GAS Piping to Fireplace LocationNatural Gas Installation Items NeededPropane/LP Connecting Fireplace to GAS SupplyPressure Testing Fireplace Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Installing Front Log #1 Installing LogsOperating Fireplace For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To Appliance Manual Lighting ProcedureThermostat Control Operation Blower OperationPilot Flame Pattern Inspecting BurnersFront Burner Flame Pattern Burner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceLogs Observed Problem Possible Cause Remedy TroubleshootingPress in control knob fully Stalling Logs, Statement above Gas leak. See WarningWiring Diagram SpecificationsService Hints Replacement PartsIllustrated Parts Breakdown LOG Base Assembly Parts ListFireplace Models VSGF28NTE and VSGF28PTE KEY Part Number Description QTY Accessories Corner Hearth Base Hardwood Hearth BaseLaminate Trim for Hearth or Mantel Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS Fireplace