Desa VsGF28nTF, VsGF28PTF Installation Clearances, Conventional Fireplace Installation

Page 10

Installation

Continued

4.Slide one end of adjusting plate/shim in slot on mitered edge of top trim (see Figure 6).

5.Slide other end of adjusting plate/shim in slot on mitered edge of side trim (see Figure 6).

6.While firmly holding edges of trim together, tighten both set screws on the adjusting plate with slotted screwdriver.

7.Repeat steps 1 through 6 for other side.

8.Tighten trim hanging screws (#10 x 6.25 shoul- der) into holes in cabinets. Place the assembled trim onto fireplace cabinet.Align hanging notches on trim with hanging screws on side of fireplace (see Figure 7). Push trim firmly into place, sliding hanging notches over hanging screws.

 

Set Screws

Side Trim Adjusting

Top

Plate

Trim

Mitered

Shim Edge

Mitered Slot

Slot Edge

Figure 6 - Assembling Perimeter Trim

Trim

Hanging

Screws

Hanging Notches on Trim

Assembled

Trim

Figure 7 - Attaching Perimeter Trim to

Fireplace

INSTALLATION CLEARANCES

WARNING: Maintain the minimum clearances. If you can, provide greater clearances from floor, ceiling, and adjoining wall.

Carefully follow these instructions. This will ensure safe installation.

Minimum Clearances For Side Combustible

Material, Side Wall, and Ceiling

A. Clearances from the side of the fireplace cabinet to any combustible material and wall should follow diagram in Figure 8.

Example: The face of a mantel, bookshelf, etc. is made of combustible material and protrudes 3 1/2" from the wall. This combus- tible material must be 4" from the side of the fireplace opening (see Figure 8).

B. Clearances from the top of the fireplace opening to the ceiling should not be less than 42".

Example

*

*Minimum 16" from Side Wall

Figure 8 - Minimum Clearance for

Combustible to Wall

Conventional Fireplace

Installation

Conventional installation of this fireplace involves installing fireplace along with the corner, face, or cabinet mantel with hearth base accessories against a wall in your home. Follow the instructions in this section to install the fireplace in this manner.

1.Assemble cabinet mantel, hearth base, and trim accessories. Assembly instructions are included with each accessory.

2.When installing blower, install a properly grounded, 120 volt three-prong electrical outlet at fireplace location if an outlet is not there. If possible, locate outlet so cabinet mantel will cover it when installed (see Figure 9, page 11).

3.Install gas piping to fireplace location. This in- stallation includes an approved flexible gas line (if allowed by local codes) after the equipment shutoff valve. The flexible gas line must be the last item installed on the gas piping. See Installing Gas Piping to Fireplace Location, page 13.

4.Place hearth base accessory against wall at instal- lation location. Cut an access hole in hearth top to run flexible gas line to fireplace (see Figure 9, page 11). Make sure to locate access hole so cabinet mantel will cover it when installed. Note: You can secure base to floor using wood screws. Countersink screw heads and putty over.

10

www.desatech.com

119303-01A

Image 10
Contents What to do if YOU Smell GAS Thermostatically-controlled Models VSGF28NTF and VSGF28PTFTable of Contents Safety InformationSafety Information Local Codes Product Identification Product FeaturesUnpacking Unusually Tight Construction Air For Combustion VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation Air From Inside Building InstallationVentilation AIR Ventilation Air From OutdoorsInstalling Hood Check GAS TypeInstallation Clearances Conventional Fireplace InstallationActual Framing Height Built-In Firebox InstallationChecking Gas Connections, Front WidthInstalling Gas Piping to Fireplace Location, Mantel Clearances for Built-In InstallationInstalling Gas Piping to Fireplace Location Installation Items NeededNatural Gas Connecting Fireplace to Gas SupplyAccessories, Propane/LPChecking GAS Connections Test Pressures Equal To or Less Than Psig 3.5 kPaInstalling Logs Pressure Testing Fireplace Gas ConnectionsOperating Fireplace For Your Safety Read Before LightingThermostat Models Thermostat Control Operation Lighting InstructionsTo Turn OFF GAS To Appliance Shutting Off FireplaceBlower Operation Manual Lighting ProcedureInspecting Burners Pilot Flame PatternCleaning Maintenance Burner Injector Holder Pilot Air Inlet HoleLogs Wiring DiagramSpecifications Model VSGF28NTAObserved Problem Possible Cause Remedy TroubleshootingIng and Maintenance, Maintenance, Stalling Logs, See Checking Gas Connec Service Hints Replacement PartsTechnical Service AccessoriesCleaning KIT GCK Duplex Outlet KIT GA3555Illustrated Parts Breakdown Models VSGF26NTF, VSGF26PTFParts List Models VSGF28PTF and VSGF28NRF Parts List Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS Fireplace System