Cleaning and |
|
Maintenance |
|
Continued |
|
| Ports/ |
Burner | Slots |
| |
Tube |
|
Pilot
Assembly
Pilot Air
Inlet Hole
Figure 34 - Pilot Inlet Air Hole
LOGS
•If you remove logs for cleaning, refer to Install- ing Logs, pages 16, to properly replace logs.
•Replace log(s) if broken or chipped
Wiring Diagram
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dan- gerous operation. Verify proper operation after servicing.
Variable
Fan Switch Fan Switch
(N.O.)
Off 1 | 2 Black |
|
| On | Blue |
|
|
Red
110/115 V.A.C. Black
GreenBlower
WhiteMotor
Specifications
Model VSGF28NTA | 21,000/28,000 Btu/Hr | |
• | Rating (Variable) | |
• | Type Gas | Natural Gas |
• | Ignition | Piezo |
•Pressure Manifold 3.4" W.C.
•Inlet Gas Pressure (in. of water)
Maximum 10.5"
Minimum* 5"
•Shipping Weight 100 lbs.
* For input adjustment
Model VSGF28PTA | 23,000/28,000 Btu/Hr | |
• | Rating (Variable) | |
• | Type Gas | Propane/LP |
• | Ignition | Piezo |
•Pressure Manifold 7.9" W.C.
•Inlet Gas Pressure (in. of water)
Maximum 14"
Minimum* 11"
•Shipping Weight 100 lbs. * For input adjustment
www.desatech.com | 21 |