Desa VsGF28nTF Lighting Instructions, To Turn OFF GAS To Appliance, Thermostat Control Operation

Page 18

OPERATING FIREPLACE

Continued

LIGHTING

INSTRUCTIONS

WARNING: You must operate this fireplace with the fireplace screen in place. Make sure fire- place screen is installed before running fireplace.

NOTICE: During initial operation of new fireplace, burning logs will give off a paper-burning smell. Orange flame will also be present. Open window to vent smell. Operate fireplace on HI position to burn off odor. This will only last a few hours.

1.STOP! Read the safety information, page 17.

2.Make sure equipment shutoff valve is fully open.

3.Turn control knob clockwise to the OFF position (see Figure 27).

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor.

If you smell gas, STOP! Follow “B” in the safety information, page 17. If you don’t smell gas, go to the next step.

5.Turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 27).

Note: If running fireplace for first time, there will be air in gas line. You may need to press in control knob for 30 seconds or longer. This will allow air to bleed from the gas system.

6.Continue pressing control knob in. Press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Ignitor Button Control Knob

Figure 27 - Control Knob and Ignitor

Button Location

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 19.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. This fireplace has a safety inter- lock system. Wait one (1) minute for system to reset before lighting pilot again.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

8.Turn control knob counterclockwise to desired heating level. The burners should light. Set control knob to any heat level between HI and LO.

CAUTION: Do not try to ad- just heating levels by using the equipment shutoff valve.

Ignitor

Pilot Burner

Electrode

 

Figure 28 - Pilot

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Fireplace

Turn control knob clockwise to the OFF position.

Shutting Off Burners Only (pilot stays lit)

Turn control knob clockwise to the PILOT position.

THERMOSTAT CONTROL

OPERATION

You can set the thermostat control knob to any comfort level between HI and LO. The thermo- stat will gradually modulate the heat output and flame height from higher to lower settings or pilot, in order to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.

Note: Selecting the HI setting will cause the burner to remain on without modulating down in most cases.

18

www.desatech.com

119303-01A

Image 18
Contents What to do if YOU Smell GAS Thermostatically-controlled Models VSGF28NTF and VSGF28PTFTable of Contents Safety InformationSafety Information Local Codes Product Features Product IdentificationUnpacking Unusually Tight Construction Air For Combustion VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation Air From Inside Building InstallationVentilation AIR Ventilation Air From OutdoorsInstalling Hood Check GAS TypeInstallation Clearances Conventional Fireplace InstallationActual Framing Height Built-In Firebox InstallationChecking Gas Connections, Front WidthInstalling Gas Piping to Fireplace Location, Mantel Clearances for Built-In InstallationInstalling Gas Piping to Fireplace Location Installation Items NeededNatural Gas Connecting Fireplace to Gas SupplyAccessories, Propane/LPChecking GAS Connections Test Pressures Equal To or Less Than Psig 3.5 kPaInstalling Logs Pressure Testing Fireplace Gas ConnectionsFor Your Safety Read Before Lighting Operating FireplaceThermostat Models Thermostat Control Operation Lighting InstructionsTo Turn OFF GAS To Appliance Shutting Off FireplaceBlower Operation Manual Lighting ProcedureInspecting Burners Pilot Flame PatternCleaning Maintenance Burner Injector Holder Pilot Air Inlet HoleLogs Wiring DiagramSpecifications Model VSGF28NTATroubleshooting Observed Problem Possible Cause RemedyIng and Maintenance, Maintenance, Stalling Logs, See Checking Gas Connec Service Hints Replacement PartsTechnical Service AccessoriesCleaning KIT GCK Duplex Outlet KIT GA3555Illustrated Parts Breakdown Models VSGF26NTF, VSGF26PTFParts List Models VSGF28PTF and VSGF28NRF Parts List Warranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS Fireplace System