Installation
Continued
Installation must include an equipment shutoff valve, union and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 18).
IMPORTANT: Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance.
Check your building codes for any special re- quirements for locating equipment shutoff valve to fireplaces.
Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves.
WARNING: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.
We recommend that you install a sediment trap in supply line as shown in Figure 18. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and fireplace. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace gas controls. If sediment trap is not installed or is installed wrong, fireplace may not run properly.
CSA
Equipment Shutoff Valve
With 1/8" NPT Tap*
| Natural Gas | |
| From Gas Meter | |
| (5" W.C.** to 10.5" | |
| W.C. Pressure) | |
| Propane/LP | |
| From External | |
3" Minimum | Regulator | |
(11" W.C.** to 14" | ||
| ||
| W.C. Pressure) |
Cap Pipe Tee
Nipple Joint
Sediment Trap
Figure 18 - Gas Connection
*Purchase the optional CSA
Accessories, page 26.
** Minimum inlet pressure for purpose of input adjustment.
CONNECTING Fireplace to Gas Supply
Installation Items Needed
• 5/16" hex socket wrench or
• Phillips screwdriver
• sealant (resistant to propane/LP gas, not pro- vided)
1.Remove fireplace screen. Remove one screw that holds fireplace screen in place for ship- ping. This screw is located near top left side of screen. Discard screw. Lift fireplace screen up and pull out to remove.
2.Remove screws that attach log base assembly to fireplace (see Figure 19). Carefully lift up log base assembly and remove from fireplace (see Figure 19).
Note: If adding the G8000 series brick liner acces- sory, install it now. Follow instructions in G8000 accessory kit.
CAUTION: Do not pick up log base assembly by burner. This could damage burner. Only handle base by grates.
3.Route gas line (provided by installer) from equipment shutoff valve to fireplace. Route flexible gas supply line through one of the access holes.
Figure 19 - Removing Log Base
Assembly From Fireplace
14 | www.desatech.com |