Hearth and Home Technologies Crescent II owner manual SRV2083-185Final placement appearance

Page 35

LAVAROCK

Figure 12.7

STEP 5: Place lava rock around the outer parts of firebox as shown.

Figure 12.8

STEP 6: Turn on ember light/ember bed. Use high temperature black paint and lightly fog the clear rock.

Note: Do not overspray the clear rock. Overspray will prevent light from shining through.

Figure 12.9

STEP 7: (SRV2083-185)Final placement appearance.

Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05

35

Image 35
Contents What to do if you smell gas Model CrescentHomeowner Reference Information CongratulationsTable of Contents 1Listing and Code Approvals Glass SpecificationsBTU Specifications High Altitude InstallationsTools and Supplies Needed Design and Installation ConsiderationsGetting Started Inspect Appliance and ComponentsSelecting Appliance Location Framing and ClearancesClearances Constructing the Appliance ChaseSpace Mantel ProjectionsVent Termination Minimum Clearances Termination LocationsVent Termination Minimum Clearances Alcove ApplicationsMeasuring Standards Vent Information and DiagramsVent Table Key Use of ElbowsTwo Elbows Vent DiagramsTop Vent Horizontal Termination One ElbowMin Max Top Vent Horizontal Termination Three ElbowsV1 = 45 ft Max .7m Top Vent Vertical Termination No ElbowThree Elbows Top Vent Vertical TerminationNon-Combustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration Framing Combustible Wall PenetrationVertical Penetration Framing Installing the Firestop SpacerInstalling Attic Shield Securing and Leveling the Appliance Appliance PreparationAssembling Pipe Sections Installing Vent PipeAssembly of Vent Sections Attaching Vent to the Firebox AssemblyAssembling DVP-12A Slip Sections Assembling Minimum Installations MI SectionsHorizontal Sections Disassembly of Vent SectionsSecuring the Vent Sections Vertical Sections Heat Shield Requirements for Horizontal Termination Installing Heat Shield and Horizontal Termination CapInstalling the Horizontal Termination Cap Pipe see Figure Installing Roof Flashing and Vertical Termination Cap16 Assembling the Storm Collar Around the Pipe Assembling and Installing Storm CollarPressure Natural Gas Propane Gas InformationFuel Conversions Gas Connection Gas PressuresHigh Altitude Installations Electrical Information Recommendation for WireConnecting to the Appliance Optional Remote Control RequirementsAppliance will not operate unless properly grounded Heat Installing Flame Control Solenoid Natural Gas Only Junction Box InstallationFacing Requirements Mantel Projections Inside Fit Surround Remove Shipping Materials Appliance SetupClean the Appliance AccessoriesPositioning the Logs Log Set Assembly LOGS-CrescentSRV2083-185Final placement appearance Replacing Light Bulb Glass AssemblyRemoving Glass Assembly Replacing Glass AssemblyBefore operating this appliance have a qualified technician Operating InstructionsBefore Lighting Appliance Intellifire Ignition Lighting ApplianceFinal Inspection by After Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Intellifire Ignition System TroubleshootingSymptom Possible Causes Corrective Actions Before servicing Maintaining and Servicing ApplianceInspect Maintenance Tasks 16Reference Materials Appliance Dimension DiagramPipe Vent Components DiagramsDVP-TRAP Series DVP Components Not for use on this Model203 Service Parts ListLog Set Assembly with burner Crescent Limited Lifetime Warranty Heat & GLO GAS Appliance Products Limited Lifetime WarrantyContact Information